Westinghouse EHB2020 4989D52G19

Westinghouse EHB2020 4989D52G19 Circuit Breaker Instruction Manual

Model: EHB2020 4989D52G19 | 2-Pole, 20A, 480VAC

1. Wprowadzenie

This manual provides essential information for the safe installation, operation, and maintenance of the Westinghouse EHB2020 4989D52G19 Circuit Breaker. Please read this manual thoroughly before attempting any installation or operation. Retain this manual for future reference.

The Westinghouse EHB2020 4989D52G19 is a 2-pole, 20 Amp, 480VAC circuit breaker designed to protect electrical circuits from overcurrents and short circuits. It is suitable for industrial and commercial applications.

2. Informacje dotyczące bezpieczeństwa

WARNING: Electrical shock hazard. Installation and servicing must be performed by qualified personnel only. Disconnect power before working on or near the circuit breaker.

  • Always ensure the main power supply is disconnected before installing, removing, or servicing the circuit breaker.
  • Stosuj odpowiedni sprzęt ochrony osobistej (PPE), taki jak rękawice termoizolacyjne i okulary ochronne.
  • Verify all connections are secure and properly torqued according to local electrical codes and manufacturer specifications.
  • Do not use this circuit breaker in environments exceeding its specified temperature or humidity ratings.
  • Nigdy nie pomijaj ani nieampz mechanizmami ochronnymi wyłącznika.

3. Koniec produktuview

The Westinghouse EHB2020 4989D52G19 circuit breaker features a robust design for reliable circuit protection. Key components include the operating handle, trip indicator, and terminal connections.

Westinghouse EHB2020 4989D52G19 Circuit Breaker front view

Rycina 1: Przód view of the Westinghouse EHB2020 4989D52G19 Circuit Breaker, showing the operating handle and rating label.

Close-up of Westinghouse EHB2020 4989D52G19 Circuit Breaker label

Rysunek 2: Szczegółowy view of the circuit breaker's label, indicating model number EHB2020, current rating 20A, 2-pole configuration, and voltage ratings (480 VAC, 250 VDC).

4. Specyfikacje

SpecyfikacjaWartość
MarkaWestinghouse
Numer modeluEHB2020 4989D52G19
Obecna ocena20 Amps
Tomtage Ocena480 V prądu przemiennego, 250 V prądu stałego
Liczba słupów2
Typ wyłącznika automatycznegoStandard (Magnetic)
Wymiary produktu23 x 16 x 18 cala (przybliżone wymiary wysyłki)
Waga przedmiotu6 funta
Interrupting Ratings10,000 Amps @ 240 Volt, 14,000 Amps przy 480 V

5. Konfiguracja i instalacja

Installation of this circuit breaker must be performed by a qualified electrician in accordance with all national and local electrical codes. Improper installation can result in serious injury or property damage.

5.1 Kontrole przed instalacją

  • Verify that the circuit breaker's ratings (voltage, current, number of poles) match the requirements of the electrical system.
  • Sprawdź wyłącznik pod kątem uszkodzeń fizycznych. Nie instaluj uszkodzonych urządzeń.
  • Ensure the panelboard or enclosure is suitable for the circuit breaker's dimensions and type.

5.2 Kroki instalacji

  1. Odłącz zasilanie: Turn off the main power supply to the electrical panel where the circuit breaker will be installed. Verify zero voltage z multimetrem.
  2. Montowanie: Securely mount the circuit breaker into the designated slot in the electrical panel. Ensure it is properly seated and latched.
  3. Połączenia przewodowe: Connect the load and line wires to the appropriate terminals on the circuit breaker. Refer to the wiring diagram of your electrical panel for correct connections.
Szczyt view of Westinghouse EHB2020 4989D52G19 Circuit Breaker terminals

Rysunek 3: Góra view showing the line terminals of the circuit breaker where incoming power is connected.

  1. Połączenia momentowe: Tighten terminal screws to the manufacturer's specified torque settings to ensure proper electrical contact and prevent overheating.
  2. Sprawdź instalację: Double-check all connections and ensure no loose wires or debris are present.
  3. Przywróć zasilanie: Po zakończeniu instalacji i jej sprawdzeniu należy przywrócić zasilanie do panelu elektrycznego.
Spód view of Westinghouse EHB2020 4989D52G19 Circuit Breaker terminals

Rysunek 4: Dół view showing the load terminals of the circuit breaker where outgoing power to the circuit is connected.

6. Instrukcja obsługi

The circuit breaker operates with a simple ON/OFF mechanism. It is designed to automatically trip (turn off) in response to overcurrent or short-circuit conditions.

  • WŁĄCZANIE: Push the operating handle firmly to the 'ON' position.
  • Wyłączanie: Push the operating handle firmly to the 'OFF' position.
  • Stan wyzwolenia: If the circuit breaker trips, the handle will move to an intermediate or 'TRIPPED' position (often between ON and OFF). To reset a tripped breaker, first push the handle completely to the 'OFF' position, then push it to the 'ON' position.

CAUTION: If the circuit breaker repeatedly trips, do not continuously reset it. This indicates an electrical fault that requires investigation by a qualified electrician.

7. Konserwacja

The Westinghouse EHB2020 4989D52G19 circuit breaker requires minimal maintenance. Regular inspections are recommended to ensure continued safe operation.

  • Kontrola wizualna: Okresowo należy sprawdzać wyłącznik automatyczny pod kątem uszkodzeń fizycznych, przebarwień lub luźnych połączeń.
  • Czyszczenie: If necessary, gently clean the exterior of the circuit breaker with a dry, lint-free cloth. Do not use liquids or abrasive cleaners.
  • Kontrola połączenia: During routine electrical system maintenance, verify that terminal connections remain tight.

OSTRZEŻENIE: Przed przystąpieniem do prac konserwacyjnych lub przeglądów należy zawsze odłączyć zasilanie.

8. Rozwiązywanie Problemów

W tej sekcji omówiono typowe problemy, na jakie możesz natrafić w związku z wyłącznikiem automatycznym.

8.1 Circuit Breaker Trips Frequently

  • Przeciążać: Obwód może pobierać zbyt duży prąd. Odłącz niektóre urządzenia lub sprzęt od obwodu.
  • Zwarcie: A direct connection between live and neutral/ground wires. This requires immediate investigation by an electrician.
  • Błąd uziemienia: Current leaking to the ground. This also requires professional diagnosis.
  • Wadliwe urządzenie: A defective appliance connected to the circuit could be causing the trip. Unplug all devices and plug them back in one by one to identify the faulty one.

8.2 Circuit Breaker Does Not Reset

  • Błąd trwały: If an overload or short circuit is still present, the breaker will not reset. Address the underlying electrical issue first.
  • Uszkodzony wyłącznik: The circuit breaker itself may be faulty and require replacement.

If troubleshooting steps do not resolve the issue, contact a qualified electrician for assistance.

9. Gwarancja i wsparcie

For warranty information and technical support regarding your Westinghouse EHB2020 4989D52G19 Circuit Breaker, please refer to the official Westinghouse webOdwiedź stronę internetową lub skontaktuj się z działem obsługi klienta. Zachowaj paragon jako dowód zakupu.

Obsługa klienta Westinghouse: Please visit the official Westinghouse webstrona zawierająca dane kontaktowe i zasoby pomocy.

Powiązane dokumenty - EHB2020 4989D52G19

Przedview Westinghouse VCP-W Vacuum Circuit Breaker: Installation, Operation, and Maintenance Manual
A comprehensive guide from Westinghouse Electric Corporation detailing the installation, operation, maintenance, and troubleshooting of Type VCP-W Vacuum Circuit Breakers, including models like 50VCP-W250, 75VCP-W500, and 150VCP-W500/750.
Przedview Westinghouse Type DHP Magnetic Air Circuit Breakers - Renewal Parts Data
This document provides renewal parts data for Westinghouse Type DHP Magnetic Air Circuit Breakers. It includes detailed information on various components, part numbers, and application guidelines for different breaker models.
Przedview Westinghouse Type VCP Vacuum Circuit Breakers: Installation, Operation, and Maintenance Manual
Comprehensive guide for Westinghouse Type VCP Vacuum Circuit Breakers, detailing installation, operation, maintenance procedures, safety practices, and renewal parts. Includes technical specifications and operational descriptions for reliable electrical protection.
Przedview Westinghouse Digitrip RMS 500 SPB Retrofit: Przewodnik po wyborze, zastosowaniu i instalacji
Comprehensive guide for selecting, applying, and installing Westinghouse Digitrip RMS 500 Trip Units as a retrofit for SPB Power Circuit Breakers equipped with Pow-R-Trip 7 or Digitrip I Trip Units. Includes safety precautions, installation steps, testing procedures, and warranty information.
Przedview Przekaźniki Westinghouse SKB i SKB-1: instrukcje instalacji, obsługi i konserwacji
Kompleksowy przewodnik po przekaźnikach Westinghouse SKB i SKB-1. Dowiedz się więcej o instalacji, obsłudze, konserwacji, ustawieniach i procedurach testowania zabezpieczeń fazowych i doziemnych w systemach linii przesyłowych.
Przedview Westinghouse WGen3600 Generator Replacement Parts List
Comprehensive replacement parts list for the Westinghouse WGen3600 portable generator, including exploded views and part numbers for the generator, control panel, and engine components.