ADVANTECH ADAM-4561

Instrukcja obsługi konwertera USB na RS-232/422/485 ADVANTECH ADAM-4561-CE z 1 portem izolowanym

Model: ADAM-4561

1. Wprowadzenie

The ADVANTECH ADAM-4561-CE is a 1-port isolated USB to RS-232/422/485 converter designed to facilitate the connection of serial devices to a computer system via a USB interface. This device eliminates the need to open the PC chassis or power down the system for installation, providing instant high-speed serial ports. Power is supplied directly from the USB port, removing the requirement for external power adapters. This makes the ADAM-4561-CE suitable for various applications including modems, printers, Point-of-Sale (POS) systems, and industrial control devices.

ADVANTECH ADAM-4561-CE 1-Port Isolated USB to RS-232/422/485 Converter

Rysunek 1: ADVANTECH ADAM-4561-CE Converter. This image displays the front view of the light blue converter unit, highlighting the USB port at the top, the "ADAM-4561" model name, and the terminal block at the bottom with clearly labeled RS-485, RS-422, and RS-232 connections.

2. Główne cechy

3. Instrukcje konfiguracji

3.1 Package Contents Verification

Przed przystąpieniem do instalacji należy sprawdzić, czy w opakowaniu znajdują się wszystkie elementy:

3.2 Instalacja sterownika

  1. Insert the provided driver CD into your computer's CD-ROM drive, or download the latest drivers from the official ADVANTECH webstrona.
  2. Locate and run the driver setup executable (e.g., "setup.exe").
  3. Postępuj zgodnie z instrukcjami wyświetlanymi na ekranie, aby dokończyć instalację sterownika. Zaleca się ponowne uruchomienie komputera po instalacji, jeśli pojawi się monit.

3.3 Połączenie sprzętowe

  1. Connect the USB cable to the USB port on the ADAM-4561-CE converter and to an available USB port on your computer. The converter will draw power directly from the USB port.
  2. Identify the appropriate serial communication standard (RS-232, RS-422, or RS-485) required by your peripheral device.
  3. Connect your serial device to the corresponding terminals on the ADAM-4561-CE's terminal block. Refer to the pinout diagram in Section 4.1 for correct wiring.

4. Instrukcja obsługi

4.1 Terminal Block Pinout

The terminal block provides connections for RS-232, RS-422, and RS-485. Ensure correct wiring based on your application.

Table 1: ADAM-4561-CE Terminal Block Pinout
Numer pinaEtykietaOpis
1TX+(DATA+)RS-485 Data Positive / RS-422 Transmit Positive
2TX-(DATA-)RS-485 Data Negative / RS-422 Transmit Negative
3Odbiornik +RS-422 Receive Positive
4RXRS-422 Receive Negative
5RXRS-232 Receive Data
6TXRS-232 Transmit Data
7GNDSygnał uziemienia
8(B) MASAIsolated Ground (for RS-485/422 bias)

4.2 Communication Software Configuration

After connecting the hardware, configure your serial communication software (e.g., HyperTerminal, PuTTY, or custom application) with the correct COM port number assigned to the ADAM-4561-CE by your operating system. You can find the assigned COM port in your computer's Device Manager under "Ports (COM & LPT)".

Ensure that the baud rate, data bits, parity, and stop bits settings in your software match those of your connected serial device.

5. Konserwacja

The ADVANTECH ADAM-4561-CE is designed for reliable operation with minimal maintenance. Follow these guidelines to ensure optimal performance:

6. Rozwiązywanie Problemów

Tabela 2: Typowe kroki rozwiązywania problemów
ProblemMożliwa przyczynaRozwiązanie
Urządzenie nie zostało rozpoznane przez komputer.Drivers not installed or corrupted. USB cable faulty. USB port issue.Reinstall drivers. Try a different USB cable. Connect to a different USB port on the computer. Check Device Manager for errors.
No communication with serial device.Incorrect COM port selected. Mismatched serial settings (baud rate, etc.). Incorrect wiring. Faulty serial device.Verify COM port in Device Manager. Ensure serial settings in software match the device. Double-check wiring according to Section 4.1. Test with a known working serial device.
Komunikacja przerywana.Loose connections. Electromagnetic interference. Driver issues.Secure all cable connections. Ensure the device is away from strong electromagnetic sources. Update or reinstall drivers.

7. Specyfikacje

8. Wsparcie techniczne i gwarancja

8.1 Wsparcie techniczne

For technical assistance, driver downloads, or further product information, please visit the official ADVANTECH website or contact their customer support department. Refer to the product packaging or ADVANTECH's official webna naszej stronie znajdziesz najnowsze dane kontaktowe.

8.2 Informacje o gwarancji

ADVANTECH products are typically covered by a limited warranty. Details regarding the warranty period and terms can be found on the ADVANTECH official webInformacje znajdują się na stronie internetowej lub w karcie gwarancyjnej dołączonej do produktu. Zachowaj dowód zakupu na wypadek roszczeń gwarancyjnych.

Powiązane dokumenty - ADAM-4561

Przedview Najczęściej zadawane pytania dotyczące P2P i GCL dla serii ADAM-6000 firmy Advantech
Często zadawane pytania dotyczące modułów serii ADAM-6000 firmy Advantech, ze szczególnym uwzględnieniem funkcjonalności Peer-to-Peer (P2P) i Group Control Logic (GCL), w tym wymagań dotyczących oprogramowania sprzętowego, zgodności i konfiguracji.
Przedview Instrukcja obsługi programowalnego sterownika automatyki serii Advantech ADAM-5550KW
Kompleksowa instrukcja obsługi programowalnego sterownika automatyki (PAC) serii ADAM-5550KW firmy Advantech, zawierająca szczegółowe informacje na temat funkcji, specyfikacji, instalacji i programowania zadań automatyki przemysłowej.
Przedview Instrukcja obsługi inteligentnej bramki wejścia/wyjścia Advantech ADAM-6700 Series
Poznaj serię Advantech ADAM-6700 – inteligentne, kompaktowe bramy do aplikacji brzegowych. Niniejsza instrukcja obsługi szczegółowo opisuje funkcje takie jak mikrokontroler Arm Cortex-A8, obsługa Node-RED, interfejsy API języka C, akwizycja danych i możliwości analizy danych brzegowych.
Przedview Moduły Advantech WISE i ADAM: rozwiązywanie problemów z żądaniami HTTP między domenami
W niniejszym dokumencie technicznym firmy Advantech opisano rozwiązanie błędu „Access-Control-Allow-Origin” występującego podczas wysyłania międzydomenowych żądań HTTP do modułów przemysłowego Internetu Rzeczy WISE i ADAM, szczegółowo opisując obsługę metody HTTP OPTIONS i wymagania dotyczące oprogramowania sprzętowego.
Przedview Krótki przewodnik po wzmacniaczu Advantech BB-485OP RS-422/485 z izolacją optyczną
Skrócona instrukcja obsługi wzmacniacza Advantech BB-485OP RS-422/485 z izolacją optyczną. Zawiera szczegółowe informacje dotyczące instalacji, rozwiązywania problemów i konfiguracji komunikacji szeregowej.
Przedview Advantech AE Dokument techniczny do udostępnienia: System Tag Kody błędów jakości komunikacji
W tym dokumencie opisano system tag error codes related to communication quality on Advantech EdgeLink, providing explanations for analog and exception quality messages.