Anderson Power Products 5915-BK

Instrukcja obsługi styku PowerPole firmy Anderson Power Products 5915-BK

Model: 5915-BK

1. Wprowadzenie

This manual provides essential instructions for the proper use, installation, and maintenance of Anderson Power Products 5915-BK PowerPole contacts. These contacts are designed for reliable electrical connections in various applications, supporting 10 or 12 AWG wire and rated for up to 75 ampsą.

Please read this manual thoroughly before proceeding with installation or use to ensure safety and optimal performance.

2. Koniec produktuview

The Anderson Power Products 5915-BK is a non-insulated copper contact specifically engineered for use with Anderson PowerPole connectors. Key features include:

  • Kompatybilność ze wskaźnikiem drutu: Designed for 10 AWG (American Wire Gauge) and 12 AWG wires.
  • Aktualna ocena: Capable of handling up to 75 Ampsą.
  • Tworzywo: Constructed from high-conductivity copper for efficient power transfer.
  • Typ połączenia: Crimp terminal for secure and durable wire attachment.
  • Aplikacja: Integral component for creating custom PowerPole cable assemblies.
Anderson Power Products 5915-BK PowerPole Contact

Figure 1: Anderson Power Products 5915-BK PowerPole Contact. This image shows a single copper contact, designed for crimping onto 10 or 12 AWG wire. The contact features a flat, spade-like end for insertion into a PowerPole housing and a cylindrical barrel for wire crimping.

3. Informacje dotyczące bezpieczeństwa

Pracując z elementami elektrycznymi należy zawsze przestrzegać następujących środków ostrożności:

  • Odłącz zasilanie: Ensure all power sources are disconnected before installing or servicing electrical connections.
  • Odpowiednie narzędzia: Use appropriate crimping tools designed for the specified wire gauge and contact type to ensure a secure connection.
  • Przekrój drutu: Match the wire gauge to the contact's specifications (10-12 AWG) to prevent overheating or poor connections.
  • Izolacja: Although these contacts are non-insulated, ensure proper insulation is applied to exposed wires and connections after assembly, typically by using PowerPole housings.
  • Profesjonalna instalacja: If you are unsure about any aspect of the installation, consult a qualified electrician.

4. Konfiguracja i instalacja

Follow these steps to properly install the 5915-BK PowerPole contact onto your wire:

  1. Prepare Wire: Strip approximately 1/4 to 3/8 inch (6-9 mm) of insulation from the end of your 10 or 12 AWG wire. Ensure the wire strands are clean and untwisted.
  2. Włóż przewód: Insert the stripped end of the wire fully into the barrel of the 5915-BK contact. The wire strands should be visible through the inspection hole (if present) or reach the end of the barrel.
  3. Crimp Contact: Using a suitable crimping tool for PowerPole contacts, crimp the contact barrel securely onto the wire. Ensure a firm, permanent connection. A good crimp will be mechanically strong and electrically sound.
  4. Inspect Crimp: Visually inspect the crimp for any loose strands or improper deformation. Gently tug on the wire to confirm it is securely held by the contact.
  5. Assemble into Housing (Optional): If using with PowerPole housings (sold separately), insert the crimped contact into the appropriate housing cavity until it clicks into place. Ensure correct polarity.

For optimal performance, always use a dedicated PowerPole crimping tool.

5. Instrukcja obsługi

Once the contacts are properly crimped onto wires and assembled into PowerPole housings (if applicable), they are ready for use. PowerPole connectors are designed for quick and reliable connection and disconnection.

  • Złączony: Align the PowerPole connectors (with contacts inserted) and push them firmly together until they lock. Ensure correct polarity (typically red for positive, black for negative).
  • Rozłączanie: Pull the PowerPole connectors apart with a firm, steady motion. Avoid pulling directly on the wires.

These contacts are designed for high current applications, ensuring minimal resistance and heat generation when properly installed.

6. Konserwacja

Anderson Power Products 5915-BK contacts require minimal maintenance. However, periodic inspection can help ensure long-term reliability:

  • Kontrola wizualna: Periodically check contacts and connections for signs of corrosion, discoloration, or physical damage.
  • Czystość: Keep contacts free from dirt, dust, and moisture. Use a clean, dry cloth for cleaning.
  • Bezpieczne połączenia: Ensure that contacts remain securely seated within their housings and that crimps are still firm.
  • Unikaj przeciążania: Nie przekraczać 75 Ampere rating to prevent overheating and potential damage.

7. Rozwiązywanie Problemów

If you experience issues with your PowerPole connections, consider the following:

  • Poor Connection/Intermittent Power:
    • Check crimp quality: Ensure the wire is securely crimped to the contact. Re-crimp if necessary.
    • Verify contact seating: Make sure the contact is fully inserted and locked into the PowerPole housing.
    • Inspect for corrosion: Clean any corrosion on the contact surfaces.
  • Overheating Connections:
    • Check wire gauge: Ensure the wire gauge (10 or 12 AWG) is appropriate for the current draw.
    • Verify current draw: Confirm that the current flowing through the connection does not exceed 75 Ampsą.
    • Inspect crimp: A poor crimp can lead to high resistance and heat.
  • Trudności z podłączaniem/odłączaniem:
    • Check for debris: Ensure no foreign objects are obstructing the connection.
    • Inspect housing: Verify that the PowerPole housings are not damaged or deformed.

8. Specyfikacje

MarkaProdukty energetyczne Andersona
Numer modelu5915-BK
Zgodność grubości drutu10 AWG, 12 AWG
Obecna ocena75 Ampjesteś
Typ złączaFałda
Materiał kontaktowyMiedź
Materiał izolacyjnyNieizolowane
Wymiary opakowania6 x 3 x 0.5 cala
Waga przedmiotu0.16 ounces (per 5 pieces)

9. Informacje o pomocy technicznej

For further assistance or inquiries regarding Anderson Power Products, please refer to the official manufacturer's website or contact their customer support. Specific warranty information is not provided in the product data.

Producent: Anderson Power Products, Inc.

Powiązane dokumenty - 5915-BK

Przedview Instrukcja montażu złączy SBE® dla serii SBE 160 i SBE 320
Szczegółowa instrukcja montażu dwubiegunowych złączy akumulatorowych serii SBE® 160 i SBE 320 firmy Anderson Power Products, obejmująca parametry znamionowe, zaciskanie, montaż oraz instalację styków pomocniczych.
Przedview Anderson Powerpole PP75 Connectors: Specifications, Ordering, and Accessories
Detailed datasheet for Anderson Powerpole PP75 connectors, covering specifications, wire ranges, housing types, contacts, temperature charts, and accessories. Rated up to 120 Amps.
Przedview Saf-D-Grid 3-Phase Power Connector for Datacenters | Anderson Power Products
Discover the Saf-D-Grid 3-Phase connector by Anderson Power Products, offering enhanced power density, compact design, and high-voltage capabilities for ICT equipment, PSUs, PDUs, and UPS systems in datacenters.
Przedview Anderson Power Products REACH-(SVHC) Declaration - Compliance Information
Declaration from Anderson Power Products regarding Substances of Very High Concern (SVHC) under REACH Regulation (EC) No. 1907/2006, confirming their products do not contain SVHCs above the 0.1% w/w threshold.
Przedview Anderson Power SBS®X-75A Assembly Instructions
Detailed assembly instructions for the Anderson Power SBS®X-75A connector, covering wire preparation, contact crimping, housing assembly, panel mounting, and IP68 protection.
Przedview BECKHOFF C9900-K936 & C9900-K937 Power Connector Assembly Instructions
Assembly instructions for BECKHOFF C9900-K936 and C9900-K937 PushPull V4 power connectors. These field-wireable plastic connectors are designed for 2.5 mm² (AWG 14) and 1.5 mm² (AWG 16) cables, featuring a 4-pole, crimp connection, IP65/IP67 protection, and straight male configuration. The document provides step-by-step assembly guidance and detailed technical specifications.