Model: FLUKE-T130
Marka: Fluke
Fluke T130 VoltagTester ciągłości obwodu to solidne i niezawodne narzędzie przeznaczone dla elektryków. Posiada duże, łatwe w obsłudze przyciski, jasny, podświetlany wskaźnik LED, wyświetlacz LCD, funkcję podtrzymywania obrazu oraz wyraźny sygnał dźwiękowy i wibracyjny.tage indicators. This two-pole tester is essential for verifying the absence of voltage before working on any circuit, ensuring user safety and accurate measurements.

Image: The Fluke T130 Voltage and Continuity Tester, showing its yellow body, black probes, backlit LCD, and LED indicators.
Always observe standard safety precautions when working with electrical equipment. Failure to do so may result in injury or damage to the tester or equipment under test.
The Fluke T130 package typically includes the following items:
The Fluke T130 requires 2 AA batteries for operation. These are typically included. To install or replace batteries:
Attach the appropriate probe tip accessories (GS38 Probe Tip Sheath or 4 mm Ø Probe Extensions) as required for your measurement application. Ensure they are securely fitted to the probe tips.
The Fluke T130 offers multiple ways to indicate the presence of voltage, including LED indicators, an LCD display, an audible tone, and tactile feedback (vibration).
The T130 features a switchable load function to avoid the display of "ghost voltages" (induced voltages in open circuits). Press the designated button to activate the load, which draws more current from the circuit under test, allowing for a more accurate voltage reading and preventing nuisance tripping of Residual Current Devices (RCDs).
For three-phase systems, the T130 can indicate phase rotation. Follow the instructions in the full user manual for detailed steps on performing this test.
Clean the tester's case with a damp cloth and mild detergent. Do not use abrasives or solvents. Ensure the tester is dry before storage or use.
Replace batteries when the low battery indicator appears on the LCD or when the tester's performance degrades. Refer to the "Battery Installation" section under Setup for instructions.
Przechowuj tester w suchym i chłodnym miejscu, z dala od bezpośredniego światła słonecznego i ekstremalnych temperatur. W przypadku przechowywania przez dłuższy czas wyjmij baterie, aby zapobiec wyciekowi.
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Tester się nie włącza. | Rozładowane lub nieprawidłowo zainstalowane baterie. | Wymień baterie, zwracając uwagę na prawidłową biegunowość. |
| Niedokładna objtage odczyty. | Duch tomtages; poor probe contact. | Activate switchable load; ensure firm probe contact. |
| No continuity indication. | Open circuit; faulty component. | Verify circuit integrity; test component separately. |
| LCD display is dim or flickering. | Niski poziom naładowania baterii. | Wymień baterie. |
| Funkcja | Szczegół |
|---|---|
| Numer modelu | FLUKE-T130 |
| Ocena bezpieczeństwa | KAT IV 600 V, KAT III 690 V |
| Źródło zasilania | Zasilany bateryjnie (w zestawie 2 baterie AA) |
| Wymiary produktu | 13.39 x 3.43 x 2.24 cala |
| Waga przedmiotu | 0.28 kilograma (9.88 uncji) |
| Wyświetlacz | Backlit LCD readout, LED indicators |
| Tomtage Wskazanie | LED, LCD, Audible Tone, Tactile Feedback (Vibration) |
| Trwałość kabla | Dual insulated cable tested to 3x required bend angle |
| Cechy specjalne | Switchable load (ghost voltage suppression), Display Hold |
| Producent | Fuks |
| Kraj pochodzenia | Zjednoczone Królestwo |
Fluke products are known for their quality and reliability. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Fluke webstrona.
For technical assistance, troubleshooting, or service, please contact Fluke customer support. Contact information can typically be found on the Fluke webmiejscu lub w opakowaniu produktu.
When contacting support, please have your product model number (FLUKE-T130) and serial number (if applicable) ready.
![]() |
Zestaw z urządzeniem weryfikującym Fluke T5-1000 / PRV240: dane techniczne i informacje o zamawianiu Kompleksowe dane techniczne i informacje dotyczące zamawiania testera elektrycznego Fluke T5-1000 i zestawu urządzeń kontrolnych PRV240, ze szczegółowymi specyfikacjami produktu, podzespołów i danymi kontaktowymi Fluke Corporation. |
![]() |
Cyfrowe multimetry kieszonkowe Fluke 106/107: dane techniczne i funkcje Szczegółowe specyfikacje techniczne, najważniejsze cechy produktów i ogólne informacje o cyfrowych multimetrach Fluke 106 i 107 w formacie dłoni. Dowiedz się więcej o ich parametrach elektrycznych, dokładności, funkcjach i dołączonym wyposażeniu. |
![]() |
Multimetr Fluke 110 True-RMS: dane techniczne i funkcje Szczegółowe specyfikacje i funkcje kompaktowego multimetru Fluke 110 True-RMS, zaprojektowanego do precyzyjnej instalacji elektrycznej i diagnostyki. Zawiera dane dotyczące dokładności, klas bezpieczeństwa i dołączone akcesoria. |
![]() |
Fluke 305 klamp Instrukcja obsługi miernika User manual for the Fluke 305 Clamp Meter, providing detailed safety information, product specifications, and operational guidance for accurate electrical measurements. |
![]() |
Fluke 323/324/325 Clamp Instrukcja obsługi miernika Kompleksowa instrukcja obsługi Fluke 323, 324 i 325 clamp mierniki, szczegółowe informacje o funkcjach, środkach ostrożności, specyfikacjach i wskazówkach operacyjnych umożliwiających dokładne pomiary elektryczne. |
![]() |
Fluke 323/324/325 Clamp Instrukcja obsługi miernika – dane techniczne i bezpieczeństwo Kompleksowa instrukcja obsługi Fluke 323, 324 i 325 Clamp Liczniki. Zawiera informacje dotyczące bezpieczeństwa, specyfikacje elektryczne i mechaniczne oraz instrukcje obsługi. |