1. Koniec produktuview
The Juniper Networks QFX5100-48S-AFI is a highly flexible, high-performance Layer 3 switch designed to provide the foundation for modern data centers. It supports cloud and Software-Defined Networking (SDN) adoption, enabling rapid deployment and delivery of applications. This switch is a universal building block for data center switching architectures, offering diverse deployment options including fabric, Layer 3, and spine and leaf configurations, allowing easy adaptation to changing requirements.

Rycina 1: Przód view of the Juniper Networks QFX5100-48S-AFI Layer 3 Switch, showing the numerous SFP+ ports.
2. Konfiguracja i instalacja
This section provides general guidelines for setting up your Juniper Networks QFX5100-48S-AFI switch. For detailed rack mounting and cabling instructions, please refer to the official Juniper Networks documentation.
2.1 Fizyczna instalacja
- Montaż w szafie: The QFX5100-48S-AFI is designed for rack-mounting. Ensure proper rack space and ventilation.
- Podłączenie zasilania: Connect the power cords to the power supply units at the rear of the switch. This unit may have more than one power supply cord. CAUTION: Disconnect all power supply cords before servicing to avoid electric shock.
- Network Cabling: Connect your network cables (fiber optic SFP+ transceivers) to the front panel ports.

Rysunek 2: Tył view of the switch, highlighting the modular power supply units and fan modules. Note the "AIR OUT" labels on the fan modules, indicating airflow direction.

Figure 3: Close-up of the AC input warning label, indicating 100-240V~50-60Hz 4.5-2A input and a caution about disconnecting all power cords before servicing.
3. Obsługa przełącznika
Once the switch is physically installed and powered on, it will begin its boot sequence. The front panel provides indicators for system status and port activity.
3.1 Wskaźniki na panelu przednim
- Diody LED stanu systemu: Monitor the ALM (Alarm), SYS (System), and MST (Master) LEDs for overall device health.
- Port Activity LEDs: Each SFP+ port has an associated LED that indicates link status and activity. A green light typically signifies an active link.

Rysunek 4: Strona view of the switch, showing mounting brackets and chassis design.

Rysunek 5: Strona przeciwna view of the switch, providing another perspective of its physical dimensions.
3.2 Interfejsy zarządzania
The switch can be managed via its console port (CON), out-of-band management Ethernet port (C0), or in-band management through a configured network interface. The USB port can be used for software upgrades or configuration backups.

Figure 6: Close-up of the product label, showing SKU: QFX5100-48S-AFI, Serial Number (SN): TA3716510011, Part Number (PN): 650-064381 REV: 09, Manufacturing Date: 20161226, and MAC Address: 08:B2:58:C4:E0:00.

Figure 7: Close-up of the regulatory compliance label, indicating compliance with FCC Part 15, CE, UL, and other certifications. It also states "ASSEMBLED IN CHINA".
4. Konserwacja
Regular maintenance ensures optimal performance and longevity of your QFX5100-48S-AFI switch.
- Czyszczenie: Keep the switch and its surroundings clean and free of dust. Use a soft, dry cloth for external cleaning. Do not use liquid cleaners.
- Przepływ powietrza: Ensure that the air intake and exhaust vents are unobstructed to maintain proper cooling. The fan modules are designed for specific airflow directions (e.g., "AIR OUT").
- Aktualizacje oprogramowania układowego: Okresowo sprawdzaj wsparcie Juniper Networks website for the latest firmware updates to ensure security and performance enhancements.
- Wymiana komponentów: Power supply units and fan modules are hot-swappable. Refer to the official documentation for safe replacement procedures.
5. Rozwiązywanie Problemów
W tej sekcji omówiono typowe problemy i ich potencjalne rozwiązania.
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Przełącznik nie włącza się. | Power cords not connected or power supply failure. | Ensure all power cords are securely connected. Check power outlets. Verify power supply unit status LEDs. |
| Dioda LED portu jest wyłączona. | No link, faulty cable, or incorrect transceiver. | Check cable connection at both ends. Replace cable. Verify transceiver compatibility and proper insertion. Check remote device status. |
| System Alarm LED (ALM) is lit. | Hardware fault, temperature issue, or power issue. | Check system logs for specific error messages. Ensure proper ventilation. Verify power supply status. Contact Juniper Networks support if the issue persists. |
6. Specyfikacje
| Funkcja | Szczegół |
|---|---|
| Numer modelu | QFX5100-48S-AFI |
| Marka | Sieci Juniper |
| Typ przełącznika | Zarządzany |
| Liczba portów | 48 (SFP+) |
| Gniazda rozszerzeń | 54 |
| Typ interfejsu | PoE, SFP |
| Materiał obudowy | Metal |
| Kolor | Szary |
| Waga przedmiotu | 21.8 funta |
| Wymiary opakowania | 36 x 24 x 12 cala |
| Producent | Juniper Networks, Inc |
| Data pierwszej dostępności | 24 grudnia 2013 r. |
| UPC | 832938068032 |
7. Gwarancja i wsparcie
Aby uzyskać szczegółowe informacje dotyczące gwarancji i pomocy technicznej, zapoznaj się z oficjalną stroną Juniper Networks website or contact their customer service. Keep your product's serial number (found on the product label, e.g., TA3716510011) readily available when seeking support.
Więcej informacji i materiałów pomocniczych znajdziesz na oficjalnej stronie Sieci Juniper webstrona.