Hubbell HBL2311

Hubbell HBL2311 20-Amp 125V Twist-Lock Plug Instruction Manual

Model: HBL2311

1. Wprowadzenie

1.1 Produkt powyżejview

The Hubbell HBL2311 is a robust 20-amp, 125-volt twist-lock plug designed for secure and reliable electrical connections. This plug features a 2-pole, 1-ground configuration, suitable for panel mount applications with 3 terminals and 1 port. Its twist-lock mechanism ensures a stable connection, preventing accidental disconnections in demanding environments. This manual provides essential information for the safe installation, operation, and maintenance of your Hubbell HBL2311 plug.

1.2 Informacje dotyczące bezpieczeństwa

WARNING: Risk of electric shock or fire. Installation and servicing should be performed by qualified personnel only. Always disconnect power at the circuit breaker or fuse box before installing or servicing this product. Follow all national and local electrical codes.

  • Ensure the power source matches the plug's voltagi i amperage ratings (125V, 20A).
  • Do not use this plug with damaged wires or if the plug itself is damaged.
  • Keep children away from electrical connections.
  • Podczas instalacji należy stosować odpowiedni sprzęt ochrony osobistej (PPE).

2. Konfiguracja i instalacja

Proper installation is crucial for the safe and effective operation of the Hubbell HBL2311 twist-lock plug. Refer to the diagram below for wire termination.

Hubbell HBL2311 20-Amp 125V Twist-Lock Plug
Rysunek 1: Hubbell HBL2311 20-Amp 125V Twist-Lock Plug. This image displays the exterior of the Hubbell HBL2311 plug, showing its robust construction and L5-20P configuration, ready for wiring.
  1. Przygotuj kabel: Strip the outer jacket of the electrical cable to the appropriate length, exposing the insulated conductors. Strip approximately 1/2 inch (12mm) of insulation from each conductor.
  2. Identyfikuj terminale: The HBL2311 plug typically has three terminals:
    • Zielona Śruba: Ziemia (G)
    • Brass Screw: Hot/Line (X or Y)
    • Silver Screw: Neutral (W)
  3. Podłącz przewody:
    • Connect the green (or bare copper) ground wire to the green screw terminal.
    • Connect the black (or colored) hot/line wire to the brass screw terminal.
    • Connect the white (or neutral) wire to the silver screw terminal.
    Ensure all wire strands are securely under the screw heads and tightened to the manufacturer's specified torque. Do not overtighten.
  4. Złóż wtyczkę: Carefully reassemble the plug housing, ensuring no wires are pinched and all components are properly seated.
  5. Sprawdź połączenie: Before restoring power, visually inspect all connections for proper wiring and tightness.

3. Działanie

The Hubbell HBL2311 twist-lock plug is designed for simple and secure connection to a compatible L5-20R receptacle.

  1. Złączony: Align the blades of the HBL2311 plug with the slots of the L5-20R receptacle. Insert the plug fully into the receptacle. Once inserted, twist the plug clockwise until it locks into place. You should feel a positive click or resistance indicating it is securely locked.
  2. Rozłączanie: To disconnect, twist the plug counter-clockwise until the blades align with the receptacle slots for removal. Pull the plug straight out from the receptacle. Do not pull by the cord.

Always ensure the equipment connected to the plug is turned off before connecting or disconnecting to prevent arcing.

4. Konserwacja

Regular inspection and basic maintenance will ensure the longevity and safe operation of your Hubbell HBL2311 plug.

  • Kontrola wizualna: Periodically inspect the plug for any signs of physical damage, such as cracks, discoloration, or bent blades. Check the cable entry for fraying or damage to the insulation.
  • Czystość: Keep the plug and receptacle free from dust, dirt, and moisture. Use a dry, clean cloth for cleaning. Do not use liquid cleaners while the plug is connected to power.
  • Integralność połączenia: Ensure the plug remains securely twisted into the receptacle during operation. If the connection feels loose, inspect both the plug and receptacle for wear.
  • Połączenia przewodowe: If the plug housing can be safely opened (after disconnecting power), periodically check the internal wire connections for tightness. Loose connections can cause overheating.

WARNING: If any damage is observed, discontinue use immediately and replace the plug. Do not attempt to repair damaged electrical components unless you are a qualified electrician.

5. Rozwiązywanie Problemów

This section addresses common issues you might encounter with the Hubbell HBL2311 twist-lock plug.

ProblemMożliwa przyczynaRozwiązanie
Plug does not lock into receptacle.Incorrect alignment; incompatible receptacle; damaged plug blades or receptacle slots.Ensure correct alignment (L5-20P to L5-20R). Verify receptacle type. Inspect plug and receptacle for damage; replace if necessary.
Power not reaching equipment.Loose connection; tripped circuit breaker; faulty wiring; damaged plug/cord.Ensure plug is fully locked. Check circuit breaker. Inspect wiring inside the plug (with power off). Test continuity of the cord and plug.
Plug feels hot during operation.Overload; loose wire connections; damaged plug.Immediately disconnect power. Reduce load on the circuit. Check internal wire connections for tightness (with power off). Replace plug if damaged or if overheating persists.

Jeśli wykonanie czynności rozwiązywania problemów nie pomoże, należy skonsultować się z wykwalifikowanym elektrykiem.

6. Specyfikacje

MarkaDzwonek
Numer modeluHBL2311
ASINB00GQR9MLY
Tomtage Ocena125 wolty
AmpOcena erage20 Amps
Typ złączaTwist-Lock (L5-20P)
Liczba przewodów3 (2-Pole, 1-Ground)
Waga przedmiotu0.16 uncji
ProducentDzwonek

7. Gwarancja i wsparcie

Hubbell products are manufactured to high-quality standards. For specific warranty information, please refer to the documentation included with your purchase or visit the official Hubbell website. For technical support or inquiries, please contact Hubbell customer service directly.

Hubbell Official Webstrona: www.hubbell.com

Powiązane dokumenty - HBL2311

Przedview Instrukcja montażu gniazda uziemiającego Hubbell Twist-Lock 50A i wtyku kołnierzowego
Oficjalna instrukcja montażu Hubbell do gniazd uziemiających Twist-Lock 50 A i gniazd kołnierzowych. Obejmuje okablowanie, montaż i środki ostrożności dla wykwalifikowanych elektryków.
Przedview Przełączniki próżniowe Trinetics UltraVac z silnikiem dielektrycznym: instrukcje instalacji i obsługi
Kompleksowa instrukcja instalacji i obsługi wyłączników próżniowych Trinetics UltraVac z silnikiem dielektrycznym firmy Hubbell. Obejmuje specyfikacje produktu, wymiary, połączenia elektryczne, ostrzeżenia dotyczące bezpieczeństwa, obsługę i konserwację.
Przedview Instrukcja instalacji i regulacji czujnika obecności IWS-ZP-3P
Kompleksowy przewodnik instalacji i regulacji czujnika obecności Hubbell IWS-ZP-3P, szczegółowo opisujący okablowanie, czas, czułość i ustawienia fotokomórki zapewniające optymalną wydajność.
Przedview Specyfikacja wyłącznika pionowego AVR typu Hubbell z aluminium
Szczegółowe specyfikacje i konfiguracje pionowego wyłącznika awaryjnego AVR typu Hubbell, obejmujące informacje o produkcie, funkcje, akcesoria, urządzenia wyłączające obciążenie i kolejność numeracji.
Przedview Instrukcja obsługi i konserwacji podgrzewacza wody z pompą ciepła Hubbell OMNI PBX
Kompleksowa instrukcja obsługi i konserwacji podgrzewacza wody z pompą ciepła Hubbell OMNI PBX, obejmująca informacje na temat instalacji, obsługi, rozwiązywania problemów i gwarancji.
Przedview Puszki ścienne wpuszczane Hubbell MULTI-CONNECT – przewodnik zamawiania
Przewodnik po zamawianiu puszek ściennych Hubbell MULTI-CONNECT, obejmujący wybór puszek ściennych, modułowych osłon (zatrzaskowych i wkręcanych) oraz kołnierzy ściennych. Szczegółowe informacje na temat dostępnych kolorów, wymiarów i konfiguracji gniazd.