1. Wprowadzenie

The FLIR MR77 Pinless Moisture Meter is a professional-grade instrument designed for accurate moisture and environmental measurements. This device combines pinless moisture detection with an external pin probe, relative humidity, and temperature sensing capabilities, making it a versatile tool for various applications.

This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of your FLIR MR77 meter to ensure optimal performance and longevity.

2. Rozpakowanie i zawartość

Carefully unpack all items from the packaging. Verify that all components are present and undamaged. If any items are missing or damaged, contact your supplier immediately.

Zawartość opakowania:

FLIR MR77 Pinless Moisture Meter

Figure 2.1: The FLIR MR77 Pinless Moisture Meter with its integrated sensor and display.

3. Konfiguracja i instalacja baterii

3.1 Instalacja baterii

  1. Znajdź komorę baterii z tyłu miernika.
  2. Otwórz pokrywę komory baterii.
  3. Insert the included 9V battery, observing correct polarity.
  4. Dokładnie zamknij pokrywę komory baterii.

3.2 Attaching Sensors

The MR77 comes with an integrated pinless sensor and ports for external sensors.

External Temperature and Relative Humidity Sensor

Figure 3.1: The external temperature and relative humidity sensor (MR01).

Pin Probe and Cable

Figure 3.2: The pin probe (MR02) for penetrating moisture measurements.

4. Instrukcja obsługi

4.1 Włączanie/wyłączanie

Naciśnij Moc button (usually located at the bottom of the device) to turn the meter on or off.

4.2 Wyświetl ponadview

Close-up of FLIR MR77 display showing moisture and temperature readings

Figure 4.1: Close-up of the MR77 display showing various readings.

The backlit LCD displays moisture readings, relative humidity, air temperature, dew point, and other relevant data. Icons indicate measurement mode, battery status, and other functions.

4.3 Tryby pomiaru

The FLIR MR77 offers multiple measurement capabilities:

Hand holding FLIR MR77 performing a pinless moisture measurement

Figure 4.2: Performing a pinless moisture measurement with the FLIR MR77.

Hand holding FLIR MR77 using the integrated IR thermometer with laser pointer

Figure 4.3: Using the integrated IR thermometer with laser targeting.

4.4 Material Group Selection

The MR77 allows selection of different material groups for more accurate moisture readings. Refer to the "Material Group Reference" table in the Specifications section for details on specific materials.

FLIR MR77 display showing material group and relative humidity

Figure 4.4: The display indicating the selected material group (M09) and Relative Humidity (RH).

4.5 Przechowywanie i przywracanie danych

Użyj PRZECHOWYWAĆ/WYWOŁAĆ button to save and retrieve measurement data. Consult the full user manual for detailed instructions on data logging and management.

4.6 Meter Link Smartphone App

The FLIR MR77 can connect to a smartphone app via Bluetooth for enhanced data monitoring, comparison, and reporting. Download the Meter Link app from your device's app store.

Screenshots of the FLIR Meter Link smartphone app showing data logging and comparison features

Figure 4.5: The Meter Link smartphone app interface for data monitoring and comparison.

5. Konserwacja

5.1 Czyszczenie

Przetrzyj zewnętrzną część licznika wodąamp cloth. Do not use abrasive cleaners or solvents. Keep the sensor areas clean and free of debris.

5.2 Wymiana czujnika

The temperature/relative humidity sensor (MR01) is field-replaceable. If readings become inaccurate or the sensor is damaged, replace it with an authorized FLIR replacement part. Refer to the full user manual for detailed replacement instructions.

5.3 Przechowywanie

Store the FLIR MR77 in a cool, dry place when not in use. Remove the battery if storing for extended periods to prevent leakage.

6. Rozwiązywanie Problemów

ProblemMożliwa przyczynaRozwiązanie
Miernik się nie włącza.Rozładowana lub nieprawidłowo zainstalowana bateria.Check battery polarity, replace battery.
Niedokładne odczyty wilgotności.Incorrect material group selected; sensor dirty or damaged; external interference.Verify material group; clean or replace sensor; move away from strong electromagnetic fields.
Inaccurate RH/Temperature readings.Czujnik zabrudzony lub uszkodzony.Clean or replace the MR01 sensor.
Problemy z łącznością Bluetooth.Meter not in pairing mode; app issues; distance from device.Ensure meter Bluetooth is active; restart app/meter; reduce distance.

For further assistance, refer to the official FLIR MR77 User Manual (PDF) or contact FLIR customer support.

7. Specyfikacje

Dane ogólne:

Specyfikacje pomiarowe:

FLIR MR77 Specifications including moisture and environmental measurements

Figure 7.1: Detailed specifications for the FLIR MR77.

Material Group Reference:

Table of Material Group Reference for FLIR MR77

Figure 7.2: Reference table for selecting appropriate material groups for moisture measurements.

This table provides common names of timbers and other materials, along with their corresponding material group numbers (e.g., Group 1-8 for timbers, Group 9 for plywood, drywall, and oriented strand board, Group 10 for brick, cement screed, and concrete, Group 11 for cement mortar, anhydrite screed, lime mortar, and plaster). Groups 10 and 11 are not specified for accuracy and should be used for reference only.

8. Informacje o gwarancji

The FLIR MR77 Pinless Moisture Meter is covered by a Ograniczona dożywotnia gwarancja. For specific terms and conditions, including details on coverage and how to make a warranty claim, please refer to the official warranty documentation provided with your product or visit the FLIR webstrona.

9. Wsparcie i dodatkowe zasoby

For further information, technical support, or to access the complete user manual, please use the resources below:

Powiązane dokumenty - MR77

Przedview Instrukcja obsługi FLIR MR77: Bezigłowy psychrometr wilgoci z termometrem na podczerwień i Bluetooth
Instrukcja obsługi FLIR MR77, bezpinowego psychrometru wilgotności z termometrem na podczerwień i łącznością Bluetooth METERLiNK. Dowiedz się więcej o jego funkcjach, obsłudze i specyfikacji.
Przedview Instrukcja obsługi FLIR MR77: Bezigłowy psychrometr wilgoci z termometrem na podczerwień
Instrukcja obsługi FLIR MR77, bezstykowego psychrometru wilgotności z termometrem na podczerwień i łącznością Bluetooth METERLiNK. Dowiedz się więcej o jego funkcjach, obsłudze i danych technicznych.
Przedview Szybki przewodnik po mierniku wilgotności FLIR MR59 z sondą kulową
Skrócona instrukcja obsługi wilgotnościomierza FLIR MR59 z sondą kulową i funkcją Bluetooth, obejmująca konfigurację, obsługę, opis miernika, przyciski funkcyjne, wskaźniki wyświetlacza i łączność Bluetooth.
Przedview FLIR MR59 Ball Probe Moisture Meter User Manual with Bluetooth
User manual for the FLIR MR59 Ball Probe Moisture Meter with Bluetooth. Provides detailed information on features, operation, maintenance, specifications, and safety guidelines for accurate moisture detection in building materials.
Przedview Instrukcja obsługi wilgotnościomierza obrazowego FLIR MR176 Plus z IGM
User manual for the FLIR MR176 Imaging Moisture Meter Plus, detailing its features, operation, maintenance, and specifications. Learn how to use its thermal imaging, pinless, and pin probe moisture measurement capabilities.
Przedview Zestaw akcesoriów FLIR E60: kompleksowa lista akcesoriów do kamer termowizyjnych
Szczegółowa lista akcesoriów do kamery termowizyjnej FLIR E60, obejmująca m.in. torby, kable, zasilacze, ładowarki, akumulatory, karty pamięci i dokumentację firmy Advanced Test Equipment Corp.