Megger TDR500/3

Instrukcja obsługi Megger TDR500/3

Basic Handheld Time Domain Reflectometer

1. Wprowadzenie

This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of the Megger TDR500/3 Basic Handheld Time Domain Reflectometer. The TDR500/3 is a compact, portable instrument designed for accurately locating faults on metallic cables, such as opens, shorts, and impedance changes.

Please read this manual thoroughly before using the device to ensure proper understanding and to prevent damage to the instrument or injury to personnel.

2. Informacje dotyczące bezpieczeństwa

WARNING: Always observe standard safety precautions when working with electrical equipment and cables. Failure to do so may result in serious injury or death.

3. Koniec produktuview

The Megger TDR500/3 is engineered for ease of use and precision in cable fault location. Its robust design and intuitive interface make it suitable for professional use in various industrial and scientific applications.

3.1 Główne cechy

3.2 Układ urządzenia

Megger TDR500/3 Handheld Time Domain Reflectometer with screen showing a trace, control buttons, and a rotary selector.

Rycina 1: Przód view of the Megger TDR500/3. The device features a monochrome LCD at the top, displaying trace data, velocity factor (UF), and impedance (Z). Below the screen are navigation buttons and a backlight control. A central four-way directional pad and a 'HOLD' button are located mid-body. The lower section includes a large rotary selector with 'AUTO', 'OFF', TDR waveform, and 'Setup' (wrench) positions, along with the Megger TDR500/3 branding.

The TDR500/3 features a clear graphical display and a user-friendly control layout:

4. Konfiguracja

4.1 Zasilanie urządzenia

The Megger TDR500/3 operates on AC power. Connect the supplied AC adapter to the device's power input and then to a suitable AC power outlet. The device does not use internal batteries.

4.2 Connecting to Cables

Before connecting the TDR500/3 to any cable, ensure the cable is completely de-energized and isolated from all power sources. Connect the appropriate test leads (not included, but typically BNC or alligator clips) to the TDR500/3's input port and then to the cable under test. Ensure a secure connection to minimize signal reflections.

5. Działanie

5.1 Włączanie/wyłączanie

To turn on the TDR500/3, rotate the main selector switch from the 'OFF' position to either 'AUTO' or the TDR measurement symbol.

To turn off the device, rotate the main selector switch to the 'OFF' position.

5.2 AUTO Selection Mode

The 'AUTO' mode simplifies operation by automatically setting the optimal range, pulse width, and gain for the cable under test. This is recommended for initial scans and general fault location.

  1. Rotate the selector switch to 'AUTO'.
  2. The TDR500/3 will automatically scan the cable and display the trace.
  3. Use the directional pad to move the cursor along the trace to identify fault locations. The distance to the cursor position will be displayed on the screen.

5.3 Manual Settings (TDR Mode)

For advanced testing or specific cable types, you can manually adjust parameters in the TDR measurement mode.

  1. Rotate the selector switch to the TDR measurement symbol.
  2. Use the directional pad and control buttons to access and adjust settings such as:
    • Velocity Factor (VF): Adjust this value (0.2 to 0.99) to match the cable's dielectric constant for accurate distance measurements. The current VF is displayed on the screen (e.g., "UF=0.69").
    • Output Impedance (Z): Select from 25, 50, 75, or 100 Ohms to match the characteristic impedance of the cable. The current impedance is displayed (e.g., "Z=100Ω").
    • Zakres: Manually set the maximum display range (e.g., "100 m").
  3. Observe the trace and use the cursor to pinpoint faults.

5.4 Trace HOLD Feature

Press the 'HOLD' button to freeze the current trace on the display. This is useful for comparing traces or for detailed analysis without the trace continuously updating. Press 'HOLD' again to resume live trace updates.

5.5 Regulacja wyświetlacza

Use the control buttons below the LCD to adjust the display contrast and backlight intensity for optimal vieww różnych warunkach oświetleniowych.

6. Konserwacja

6.1 Czyszczenie

Przetrzyj instrument miękką,amp Ściereczką. Nie używaj środków czyszczących o działaniu ściernym ani rozpuszczalników. Upewnij się, że do urządzenia nie dostanie się wilgoć.

6.2 Przechowywanie

Store the TDR500/3 in a clean, dry environment within the specified operating temperature range. Protect it from dust, moisture, and extreme temperatures.

6.3 Kalibracja

Regular calibration by authorized service centers is recommended to ensure the continued accuracy and performance of the TDR500/3. Refer to Megger's official documentation or website for recommended calibration intervals.

7. Rozwiązywanie Problemów

ProblemMożliwa przyczynaRozwiązanie
Urządzenie nie włącza się.No AC power, faulty power adapter, or internal issue.Check AC power connection. Ensure power adapter is functioning. If problem persists, contact Megger support.
Unclear or noisy trace.Incorrect impedance setting, poor cable connection, or external interference.Verify impedance setting matches cable. Ensure test leads are securely connected. Check for strong electromagnetic interference.
Incorrect distance readings.Incorrect Velocity Factor (VF) setting.Adjust the VF setting to match the known velocity factor of the cable under test. Refer to cable specifications.
Wyświetlacz jest zbyt ciemny lub zbyt jasny.Display contrast or backlight settings are incorrect.Adjust display contrast and backlight using the control buttons below the LCD.

For issues not listed here, or if solutions do not resolve the problem, please contact Megger customer support.

8. Specyfikacje

ParametrWartość
Numer modeluTDR500/3 (also 1002-227)
Rezolucja0.1 metrów (0.3 stóp)
Maksymalny zasięg5 km (15,000 ft) (dependent on VF and cable type)
Output Impedances25, 50, 75, 100 Ω
Velocity Factor (VF) Rangeod 0.2 do 0.99
Typ wyświetlaczaBacklit Graphics Monochrome LCD (256 x 128 pixels)
Źródło zasilaniaAC (external adapter)
Waga przedmiotu3.65 funta
Wymiary produktu (dł. x szer. x wys.)9.06 x 1.89 x 4.53 cala
Kraj pochodzeniaZjednoczone Królestwo
StosowanieProfesjonalny

9. Gwarancja i wsparcie

Megger products are designed for reliability and performance. For information regarding warranty coverage, technical support, service, or replacement parts, please contact Megger customer service or visit the official Megger website. Please have your product model number (TDR500/3) and serial number ready when contacting support.

Aktualne dane kontaktowe znajdziesz na stronie: www.megger.com

Powiązane dokumenty - TDR500/3

Przedview Megger TDR500 User Guide: Time Domain Reflectometer Specifications and Operation
Comprehensive user guide for the Megger TDR500 Time Domain Reflectometer, covering mechanical, environmental, and electrical specifications, cable velocity factors, safety warnings, and operational details.
Przedview Megger TDR1000/3 Échomètre de Poing: Techniki i specyfikacje techniczne
Découvrez le Megger TDR1000/3, un échomètre de poche portable et compact pour la localisation précise des défauts sur câbles métalliques. Idéal pour les techniciens, il offre une haute résolution, une large portée et des fonctionnalités intuitives comme le réglage AUTO et la fonction HOLD.
Przedview Testery rezystancji izolacji Megger ADVANCED o zakresie 5 kV, 10 kV, 15 kV
Poznaj solidną i niezawodną serię testerów rezystancji izolacji Megger ADVANCED o napięciu 5 kV, 10 kV i 15 kV. Odkryj zaawansowane funkcje, takie jak tryb RE>Act dla większej dokładności, predyktor PI dla szybszego testowania oraz wysoka zmienność.tagZakres pomiaru do 30 TΩ. Zaprojektowane do zastosowań przemysłowych, te testery oferują najwyższy poziom bezpieczeństwa (klasa CAT IV) i intuicyjną obsługę, co pozwala na wydajną konserwację i testowanie instalacji elektrycznych.
Przedview Instrukcja obsługi jednostki ładującej akumulator Megger TORKEL serii 900
Niniejsza instrukcja obsługi zawiera szczegółowe instrukcje dotyczące obsługi urządzeń obciążających akumulatory Megger TORKEL serii 900. Obejmuje ona funkcje produktu, wytyczne dotyczące bezpieczeństwa, procedury testowe, nawigację w menu, pomiar prądu zewnętrznego oraz wyposażenie opcjonalne, takie jak dodatkowe obciążenia TXL i wskaźnik pojemności akumulatora BVM.tagMonitory e są niezbędne w zastosowaniach przemysłowych, na stacjach elektroenergetycznych i w centrach danych.
Przedview Testery izolacji Megger MIT400/2 CAT IV: funkcje, specyfikacje i zastosowania
Kompleksowa karta katalogowa testerów izolacji i ciągłości obwodu Megger serii MIT400/2 CAT IV. Szczegółowe informacje na temat funkcji, specyfikacji, zastosowań, bezpieczeństwa oraz porównania modeli do testów elektrycznych i przemysłowych.
Przedview Instrukcja obsługi urządzenia Megger TORKEL serii 900: Działanie i specyfikacja modułu obciążenia akumulatorowego
Kompleksowy podręcznik użytkownika akumulatorowych jednostek obciążeniowych Megger TORKEL serii 900. Obejmuje opis produktu, funkcje, instrukcje bezpieczeństwa, obsługę, procedury testowe, wyposażenie opcjonalne, takie jak dodatkowe obciążenia TXL i BVM, rozwiązywanie problemów oraz specyfikacje techniczne.