1. Ważne informacje dotyczące bezpieczeństwa
OSTRZEŻENIE: Installation and servicing of heating, ventilation, and air conditioning (HVAC) equipment can be hazardous due to system pressure, electrical components, and equipment location. Only qualified, trained, and experienced service personnel should install, repair, or service HVAC equipment. Failure to follow these instructions could result in property damage, personal injury, or death.
- Always disconnect all electrical power to the furnace before installing or servicing this control board.
- Verify proper wiring connections according to the furnace manufacturer's specifications.
- Ensure all safety devices are correctly installed and functioning after replacement.
- Podczas instalacji należy nosić odpowiedni sprzęt ochrony osobistej (PPE).
2. Koniec produktuview
The York Furnace Control Circuit Board S1-03101264002 is an OEM (Original Equipment Manufacturer) upgraded replacement part designed for specific York furnace models. This board serves as the central control unit for your furnace, managing various functions such as ignition, fan operation, and safety shutdowns.

Rysunek 1: York Furnace Control Circuit Board S1-03101264002. This image displays the circuit board with various electronic components, connectors, and relays.
3. Instrukcje instalacji
These instructions provide a general guide for replacing a furnace control board. Always refer to your specific furnace model's service manual for detailed, model-specific instructions.
- Odłączenie zasilania: Wyłącz zasilanie elektryczne pieca za pomocą głównego panelu serwisowego. Sprawdź, czy zasilanie jest wyłączone za pomocą przełącznika głośności.tage metr.
- Dostęp do Panelu Sterowania: Zlokalizuj i otwórz panel dostępu do pieca, aby odsłonić istniejącą płytę sterowniczą.
- Okablowanie dokumentów: Before disconnecting any wires, take clear photographs of all wiring connections to the old board. Label each wire and its corresponding terminal for accurate reinstallation.
- Odłącz przewody: Carefully disconnect all wires and connectors from the old control board.
- Usuń starą tablicę: Unscrew or unclip the old control board from its mounting location.
- Zainstaluj nową płytę: Mount the new York S1-03101264002 control board in the same position as the old one.
- Ponowne podłączenie przewodów: Using your photographs and labels, carefully reconnect all wires and connectors to the new board. Ensure all connections are secure.
- Zamknij Panel dostępu: Zamknij szczelnie panel dostępu do pieca.
- Przywróć zasilanie: Przywróć zasilanie elektryczne pieca za pomocą głównego panelu serwisowego.
- Operacja testowa: Initiate a heating cycle and observe the furnace's operation to ensure all functions (ignition, fan, etc.) are working correctly.
4. Zasady działania
The control board operates by receiving signals from the thermostat and various safety sensors within the furnace. It then initiates the appropriate sequence of operations for heating or cooling.
- Kontrola zapłonu: Manages the sequence for igniting the burners.
- Sterowanie wentylatorem dmuchawy: Activates and deactivates the indoor blower fan for air circulation.
- Monitorowanie bezpieczeństwa: Continuously monitors safety limits and sensors, shutting down the furnace if an unsafe condition is detected.
- Kody diagnostyczne: Many control boards feature LED indicators that flash diagnostic codes to assist in troubleshooting. Refer to your furnace manual for specific code interpretations.
5. Konserwacja
The control board itself requires no routine maintenance. However, ensuring the overall furnace system is well-maintained can prolong the life of all components, including the control board.
- Regularna wymiana filtra: Replace or clean your furnace air filter regularly to ensure proper airflow and prevent overheating, which can stress electronic components.
- Roczna kontrola zawodowa: Have a qualified HVAC technician inspect your furnace annually. They can identify potential issues before they lead to component failure.
- Utrzymuj obszar w czystości: Ensure the area around the furnace is free from obstructions and combustible materials.
6. Rozwiązywanie Problemów
Before attempting any troubleshooting, ensure all power to the furnace is disconnected. If you are unsure about any step, contact a qualified HVAC technician.
Typowe problemy i potencjalne rozwiązania:
- Piec nie uruchamia się:
- Sprawdź ustawienia termostatu.
- Verify power supply to the furnace.
- Inspect furnace filter for blockage.
- Sprawdź, czy wyłączniki obwodowe nie zostały wyłączone.
- Consult your furnace manual for diagnostic codes displayed on the control board.
- Blower Fan Runs Continuously:
- Ensure thermostat fan setting is on "Auto" and not "On".
- A faulty fan relay on the control board or a stuck limit switch could be the cause. Professional diagnosis is recommended.
- Działanie przerywane:
- Luźne połączenia przewodów.
- Faulty safety sensors (e.g., flame sensor, limit switch).
- Wahania mocy.
For complex issues or if basic troubleshooting does not resolve the problem, it is strongly recommended to contact a certified HVAC technician.
7. Specyfikacje
| Funkcja | Szczegół |
|---|---|
| Marka | JORK |
| Numer modelu | S1-03101264002 (OEM Upgraded Replacement) |
| Wymiary produktu | 8 x 6 x 10 cala |
| Waga przedmiotu | 8 uncji |
| Producent | Jork |
| Pierwsza dostępna data | 9 sierpnia 2013 r. |
8. Informacje o gwarancji
Specific warranty terms for the York Furnace Control Circuit Board S1-03101264002 may vary depending on the seller and date of purchase. It is recommended to retain your proof of purchase and consult the seller or manufacturer's official documentation for detailed warranty coverage and claim procedures.
9. Wsparcie
For technical assistance, installation guidance, or troubleshooting beyond the scope of this manual, please contact a qualified HVAC professional or refer to the official York customer support channels.