Madison M5000

Instrukcja obsługi

Madison M5000 Liquid Level Sensor

Produkt ponadview

The Madison M5000 is a miniature float switch designed for reliable liquid level detection. Constructed from 316 stainless steel, it is suitable for a wide range of applications, including those requiring superior corrosion resistance, high temperatures, or use in medical, petrochemical, and food processing environments. This sensor detects high or low liquid levels within a container.

Madison M5000 Liquid Level Sensor

Rysunek 1: Madison M5000 Liquid Level Sensor. This image shows the stainless steel float switch with its threaded stem and electrical lead wires extending from the top. The main body is cylindrical, designed to float or sink with liquid levels.

Informacje dotyczące bezpieczeństwa

Before installation and operation, read and understand all instructions. Failure to do so may result in product damage, property damage, or personal injury. Ensure all electrical connections comply with local and national electrical codes. Disconnect power before installing or servicing the sensor.

  • Do not exceed the maximum pressure and temperature ratings of 300 PSI and 392°F (200°C).
  • Ensure the sensor is rated for the specific liquid and environment it will be used in.
  • Switches are rated for resistive loads. Refer to UL guidelines for current (Amperes resistive) at different voltagt.j.

Konfiguracja i instalacja

The M5000 sensor is designed for vertical mounting using its 1/8" NPT thread. It can be installed to detect either high or low liquid levels depending on its orientation.

Orientacja montażu:

  • Normally Open (NO) Operation: For high-level detection, mount the sensor so the float is at the bottom and rises with the liquid. The switch will close when the liquid reaches the float.
  • Normally Closed (NC) Operation: For low-level detection, mount the sensor so the float is at the top and falls with the liquid. The switch will open when the liquid drops below the float.

Kroki instalacji:

  1. Identify the desired mounting location in the container, ensuring it is clean and free of debris.
  2. Thread the 1/8" NPT stem into the appropriate port. Use a suitable sealant (e.g., PTFE tape) on the threads to ensure a leak-proof seal. Do not overtighten.
  3. Connect the 24", 22 AWG Teflon insulated lead wires to your control circuit. Refer to the electrical specifications for appropriate voltage i aktualne oceny.
  4. Verify the float moves freely without obstruction within the container.

Zasady działania

The Madison M5000 operates on a simple magnetic principle. Inside the stainless steel stem, there is a hermetically sealed reed switch. The float, which contains a magnet, moves along the stem as the liquid level changes. When the magnet in the float comes into proximity with the reed switch, it causes the switch contacts to open or close, signaling the liquid level status to the connected control system.

The float has a specific gravity (SG) of 0.70, meaning it will float in liquids with an SG greater than 0.70. For liquids with an SG less than 0.70, the float will sink, and the sensor's operation will be inverted.

Konserwacja

The Madison M5000 liquid level sensor is designed for minimal maintenance due to its robust stainless steel construction. However, periodic inspection is recommended to ensure optimal performance.

  • Czyszczenie: If the sensor is used in applications with viscous or particulate-laden liquids, the float and stem may accumulate residue. Periodically clean the float and stem to ensure free movement. Use cleaning agents compatible with 316 stainless steel.
  • Kontrola: Check the lead wires for any signs of damage or wear. Ensure the NPT connection remains secure and leak-free.
  • Test funkcjonalności: If possible, periodically test the sensor's operation by manually raising or lowering the liquid level (or simulating it) to confirm the switch activates correctly.

Rozwiązywanie problemów

ProblemMożliwa przyczynaRozwiązanie
Czujnik nie aktywuje się
  • Nieprawidłowe okablowanie
  • Float obstructed or stuck
  • Liquid specific gravity too low
  • Damaged reed switch
  • Verify wiring against electrical diagram.
  • Inspect and clean float/stem for obstructions.
  • Ensure liquid SG is > 0.70 for standard operation.
  • Test switch continuity; replace if faulty.
Odczyty okresowe
  • Luźne połączenia elektryczne
  • Wibracja
  • Klejenie pływakowe
  • Sprawdź i zabezpiecz wszystkie połączenia przewodów.
  • Ensure stable mounting; consider anti-vibration measures.
  • Clean float and stem.
Leakage at mounting point
  • Niewłaściwy uszczelniacz gwintów
  • Niewystarczające dokręcenie
  • Uszkodzone gwinty
  • Reapply appropriate thread sealant.
  • Tighten connection to recommended torque (without overtightening).
  • Inspect threads for damage; replace sensor or fitting if necessary.

Specyfikacje

ParametrWartość
Numer modeluM5000
Materiał łodygiStal nierdzewna 316
Materiał pływającyStal nierdzewna 316
Float Specific Gravity (SG)0.70
Gwint montażowy1/8" NPT
Maksymalne ciśnienie300 PSI
Maksymalna temperatura392°F (200°C)
Przełącz ocenę30 Watt, SPST (Single Pole, Single Throw)
Parametry elektryczne
  • 240 V AC, 0.14 A
  • 120 V AC, 0.28 A
  • 120 V DC, 0.07A
  • 24 V DC, 0.28A
Druty przewodowe24", 22 AWG, Teflon Insulated
ZatwierdzeniaCE, UL, NSF
Wymiary produktu9.06 x 6.3 x 7.09 cala; 1.6 uncji

Note: Switches are rated for resistive loads. Refer to UL guidelines for current (Amperes resistive) at different voltagt.j.

Informacje o gwarancji

Specific warranty details for the Madison M5000 Liquid Level Sensor are typically provided at the point of purchase or can be obtained directly from Madison Company. Please retain your proof of purchase for warranty claims.

Wsparcie i kontakt

For technical assistance, troubleshooting beyond this manual, or inquiries regarding parts and service, please contact Madison Company directly. Contact information can typically be found on the manufacturer's official webwitryny lub opakowania produktu.

Manufacturer: Madison Company

Powiązane dokumenty - M5000

Przedview Madison FREESOUND-VR30 User Manual
User manual for the Madison FREESOUND-VR30 vintage radio, covering setup, operation, safety instructions, specifications, and disposal information.
Przedview Madison FREESOUND-VR30 Akumulator Vintage Radio with Bluetooth & FM - User Manual
This user manual provides comprehensive instructions for the Madison FREESOUND-VR30 vintage radio, covering safety guidelines, product features, operation, specifications, and proper disposal.
Przedview Przewodnik informacyjny Madison Custom Printed: Projekt logo, pomiary końcowe i dopasowanie kolorów
Dowiedz się, jak przygotować projekt logo, zmierzyć słupki do druku niestandardowego i dopasować kolory, korzystając z kompleksowego przewodnika Madison. Niezbędne informacje dotyczące sprzętu i odzieży sportowej z nadrukiem na zamówienie.
Przedview Instrukcja obsługi głośnika imprezowego Bluetooth Madison MAD-MUSICA50
Odkryj funkcje i obsługę głośnika imprezowego Bluetooth Madison MAD-MUSICA50 dzięki tej obszernej instrukcji obsługi. Zawiera ona szczegółowe instrukcje, objaśnienia sterowania i specyfikacje techniczne w wielu językach, co zapewnia optymalne użytkowanie.
Przedview Madison FREESOUND-VR40 Vintage Instrukcja obsługi radia Bluetooth FM
Pełna instrukcja obsługi Madison FREESOUND-VR40 vintage-radio, szczegółowo omawiając takie funkcje, jak Bluetooth, odtwarzanie przez USB, radio FM, instrukcje bezpieczeństwa, obsługę i specyfikacje.
Przedview Madison Side Table Assembly Instructions
Step-by-step assembly guide for the Madison Side Table, including parts list, fittings, and detailed instructions for easy setup.