Johnson Controls MR4PMUHV-12C

Instrukcja obsługi sterownika odszraniania Johnson Controls MR4PMUHV-12C

1. Wprowadzenie

The Johnson Controls MR4PMUHV-12C Defrost Control is engineered for use in refrigeration and freezer units, supporting both hot gas and electric heat defrost methods. This control unit offers flexible defrost termination options, allowing selection between time-based or temperature-based methods. It integrates essential control functions including compressor management, defrost cycle management, fan operation control, and alarm management, providing a comprehensive solution for HVAC systems.

Johnson Controls MR4PMUHV-12C Defrost Control unit with two coiled temperature sensors

Rysunek 1: Johnson Controls MR4PMUHV-12C Defrost Control unit and included temperature sensors. The central gray unit features a digital display and control buttons, while two coiled gray cables with metallic tips represent the temperature sensors.

2. Co znajduje się w pudełku

3. Główne cechy

4. Konfiguracja i instalacja

Proper installation is crucial for the safe and efficient operation of the defrost control. Always ensure power is disconnected before beginning any installation or wiring procedures.

  1. Bezpieczeństwo przede wszystkim: Disconnect all power to the refrigeration or freezer unit before proceeding. Follow all local electrical codes and safety guidelines.
  2. Montowanie: Select a suitable location for mounting the control unit and, if applicable, the separate relay pack. Ensure adequate ventilation and protection from moisture. The flexible design allows for combined or separate mounting.
  3. Połączenia elektryczne:
    • Connect the 24VAC power supply to the designated terminals on the control unit.
    • Wire the compressor, fans, and defrost heaters to the heavy-duty relay terminals as per the wiring diagram provided with the product.
    • Connect any external alarm systems to the dedicated alarm terminals.
  4. Instalacja czujnika: Install the temperature sensors in the appropriate locations within the evaporator or process area as required for accurate temperature monitoring. Ensure sensor cables are routed safely and securely.
  5. Początkowe uruchomienie: Once all connections are secure and verified, restore power to the unit. The control unit display should illuminate.

5. Działanie

After successful installation, the MR4PMUHV-12C is ready for configuration and operation.

  1. Wyświetl ponadview: Upon power-up, the digital display will show the current temperature. Pressing the designated button (refer to product-specific labeling) allows toggling between evaporator and process temperature readings.
  2. Setting Defrost Parameters: Access the control unit's menu (typically via dedicated buttons) to configure defrost settings. This includes:
    • Odstęp odszraniania: Set the frequency at which defrost cycles occur.
    • Defrost Duration: Specify the maximum time for a defrost cycle.
    • Defrost Termination Method: Choose between time-based termination (defrost ends after a set duration) or temperature-based termination (defrost ends when a specific temperature is reached).
    • Fan Delay: Configure any fan delay settings post-defrost.
  3. Ustawienia alarmu: Configure temperature thresholds for alarms to ensure optimal operating conditions and prompt notification of deviations.
  4. Monitorowanie: Regularly check the display for current temperatures and system status.

6. Konserwacja

Routine maintenance helps ensure the longevity and reliable performance of your defrost control unit.

7. Rozwiązywanie Problemów

W tej sekcji znajdziesz wskazówki dotyczące typowych problemów. W przypadku skomplikowanych problemów skontaktuj się z wykwalifikowanym personelem serwisowym.

8. Specyfikacje

Numer modeluMR4PMUHV-12C
Wymiary produktu10.5 x 5.5 x 6.5 cala
Waga przedmiotu3.17 Pounds (3.2 Pounds listed elsewhere)
MarkaKontrole Johnsona
TworzywoPlastikowy
Temperatura pracy32 stopni Fahrenheita (0°C)
ProducentJohnson Controls Inc

9. Gwarancja i wsparcie

For information regarding product warranty, technical support, or service, please contact Johnson Controls directly or refer to the official documentation included with your purchase. Keep your proof of purchase for warranty claims.

Johnson Controls Contact Information: Please visit the official Johnson Controls webstrona zawierająca najnowsze dane kontaktowe i zasoby pomocy.

Powiązane dokumenty - MR4PMUHV-12C

Przedview Instrukcja instalacji elektronicznych regulatorów temperatury Johnson Controls serii A421 z funkcją odszraniania poza cyklem
Kompleksowy przewodnik instalacji elektronicznych regulatorów temperatury Johnson Controls PENN serii A421 z funkcją odszraniania poza cyklem. Obejmuje produkty z serii PENN.view, zastosowania, wymiary, montaż, okablowanie, konfiguracja, regulacje, rozwiązywanie problemów i specyfikacje techniczne.
Przedview Elektroniczne regulatory temperatury serii A419 z wyświetlaczem i wodoszczelnymi obudowami NEMA 1 lub NEMA 4X
W tym biuletynie technicznym firmy Johnson Controls szczegółowo opisano elektroniczne regulatory temperatury serii A419 przeznaczone do pojedynczychtagZastosowania chłodnicze i HVAC. Obejmuje funkcje, zalety, opcje obudów NEMA 1 i NEMA 4X, obsługę, okablowanie, regulacje, rozwiązywanie problemów, kody błędów, informacje o zamówieniach oraz specyfikacje techniczne.
Przedview Johnson Controls A19 Series Zdalne sterowanie żarówkami – czujniki temperatury
Szczegółowa specyfikacja i przewodnik doboru zdalnych regulatorów temperatury Johnson Controls serii A19, stosowanych w systemach HVAC, ogrzewania, wentylacji i chłodnictwa. Zawiera numery modeli, parametry elektryczne i funkcje.
Przedview Strona katalogowa zdalnego sterowania żarówkami serii PENN A19 | Johnson Controls
Strona katalogowa zdalnego sterowania żarówką PENN serii A19 z pojedynczymi elementamitagRegulatory temperatury z czujnikami wypełnionymi cieczą. Zawiera tabele doboru, specyfikacje techniczne, części zamienne i dane kontaktowe.
Przedview Instrukcja obsługi termostatu z ekranem dotykowym Hx 3
Niniejsza instrukcja obsługi zawiera szczegółowe instrukcje i wskazówki dotyczące termostatu z ekranem dotykowym Johnson Controls Hx 3 (model: S1-THXU430W), obejmujące instalację, funkcje, obsługę, łączność z aplikacją i ustawienia.
Przedview Instrukcja montażu elementów sterujących zapłonem przerywanym serii G600
Kompleksowy przewodnik po instalacji, montażu, okablowaniu, konfiguracji, obsłudze i rozwiązywaniu problemów dla układów zapłonowych z zapłonem przerywanym serii G600 firmy Johnson Controls.