Fluke FLUKE-355

Fluke 355 True RMS klamp- Instrukcja obsługi miernika

Model: FLUKE-355

Wstęp

The Fluke 355 digital clamp-meter is a true RMS sensing, auto-ranging multimeter designed for precise measurement of current, voltage, frequency, and resistance in various electrical testing applications. It features a robust clamp mechanism for non-contact current measurement and a comprehensive set of functions for professional use, ensuring accurate readings for both linear and non-linear loads.

Informacje dotyczące bezpieczeństwa

Always adhere to safety precautions when working with electrical equipment. This device is designed to meet IEC safety standard 61010-2-032.

  • CAT IV, 600V: Suitable for measurements at the source of the low-voltage installation, such as electricity meters and primary over-current protection equipment.
  • CAT III, 1,000V: Suitable for measurements within fixed installations, including switches and industrial equipment permanently connected to the fixed installation.

Ensure proper personal protective equipment (PPE) is used, and always follow local safety regulations when operating this device.

Co jest w pudełku

Your Fluke 355 Clamp-Meter package includes the following components:

  • Fluke 355 digital clamp-metr
  • Zestaw przewodów pomiarowych
  • Zestaw sond testowych
  • Zestaw klipsów krokodylkowych
  • (6) baterie AA
  • Miękki futerał
  • Instrukcja obsługi
Contents of the Fluke 355 Clamp-Meter package laid out, including the meter, test leads, alligator clips, soft carrying case, and user manual.

Image: All components included with the Fluke 355 Clamp-Meter, neatly arranged.

Cechy produktu

  • Wykrywanie prawdziwej wartości skutecznej: Provides accurate readings for both linear and non-linear loads, regardless of waveform.
  • Pomiar wysokiego prądu: Measures AC and DC current up to 2,000A (1,400A AC RMS).
  • Large Jaw Opening: 58mm (2.3 inches) jaw opening accommodates large or multiple conductors for non-contact current measurement.
  • Tomtage Pomiar: Mierzy AC objtage do 600 V i DC objtage do 1,000V.
  • Frequency and Resistance: Measures frequency up to 1kHz and resistance up to 400kΩ.
  • Inrush Current Function: Analyzes surge current during motor startup and other inductive loads for stable measurements.
  • Filtr dolnoprzepustowy: Reduces high-frequency interference for accurate measurements of complex waveforms.
  • Min/Max Function: Toggles to display lowest, highest, and average readings.
  • Przechowywanie danych: Freezes the reading on the display for easy documentation in tight spaces.
  • Brzęczyk ciągłości: Confirms electrical continuity.
  • Podświetlany wyświetlacz LCD: Improves visibility in low-light conditions, with automatic backlight shut-off.
  • Automatyczne wyłączanie: Conserves battery life by automatically turning off after 20 minutes of non-use.
  • Wskaźnik niskiego poziomu naładowania baterii: Signals when batteries need replacement.

Organizować coś

Instalacja baterii

The Fluke 355 requires six 1.5V AA batteries for operation. These are typically included with your purchase.

  1. Znajdź pokrywę komory baterii z tyłu urządzenia.
  2. Aby otworzyć pokrywę, użyj śrubokręta.
  3. Insert the six AA batteries, ensuring correct polarity (+/-).
  4. Załóż pokrywę komory baterii i zabezpiecz ją.

Inspekcja wstępna

Przed pierwszym użyciem należy sprawdzić stanamp-meter, test leads, and accessories for any signs of damage. Do not use the device if any damage is observed.

Instrukcja obsługi

Włączanie/wyłączanie

Turn the rotary switch to any measurement function to power on the device. Turn the rotary switch to "OFF" to power off. The device will automatically power off after 20 minutes of inactivity to conserve battery life.

Measuring AC/DC Current (Clamp Funkcjonować)

  1. Turn the rotary switch to the "A AC+DC" position.
  2. Naciśnij dźwignię zwalniającą szczękę, aby otworzyćamp szczęki
  3. Umieść klamp jaws around a single conductor. Ensure the jaws are fully closed.
  4. Odczytaj aktualną wartość na wyświetlaczu LCD.
Fluke 355 klamp-Meter with its jaws clamped around a thick electrical cable, demonstrating current measurement.

Obraz: clamp jaws of the Fluke 355 securely closed around an electrical conductor for current measurement.

Pomiar objętościtage (AC/DC)

  1. Connect the test leads to the appropriate input jacks (COM and V).
  2. Turn the rotary switch to the "V AC+DC" position.
  3. Podłącz sondy pomiarowe do obwodu lub elementu, który chcesz zmierzyć.
  4. Przeczytaj tomtage wartość na wyświetlaczu LCD.

Measuring Resistance (Ω)

  1. Connect the test leads to the appropriate input jacks (COM and Ω).
  2. Ustaw przełącznik obrotowy w pozycji „Ω”.
  3. Przed pomiarem rezystancji należy upewnić się, że obwód jest odłączony od napięcia.
  4. Podłącz sondy pomiarowe do mierzonego elementu.
  5. Odczytaj wartość rezystancji na wyświetlaczu LCD.

Inne funkcje

  • ZASIĘG: Manually select the measurement range if auto-ranging is not desired.
  • TRZYMAĆ: Naciśnij, aby zamrozić aktualny odczyt na wyświetlaczu. Naciśnij ponownie, aby zwolnić.
  • ZERO: Used to zero out DC current readings or resistance readings for lead compensation.
  • Hz: Pomiar częstotliwości.
  • NAPÓR: Measures the peak current during motor startup.
  • MIN MAX: Toggles through minimum, maximum, and average readings captured during a measurement session.
  • FILTR: Activates a low-pass filter to reduce electrical noise for stable readings.
Przód view of the Fluke 355 Clamp-Meter, showing its large digital display, rotary switch, and function buttons.

Obraz: Szczegółowy view of the Fluke 355 Clamp-Meter's display and control panel.

Konserwacja

Czyszczenie

Wyczyść licznik casing z reklamąamp Ściereczką i łagodnym detergentem. Nie używaj środków ściernych ani rozpuszczalników. Utrzymuj wyświetlacz w czystości i suchości.

Wymiana baterii

When the low-battery indicator appears on the display, replace all six AA batteries promptly to ensure accurate measurements. Follow the battery installation steps outlined in the Setup section.

Składowanie

Przechowuj clamp-meter in its soft carrying case in a dry, dust-free environment when not in use. Remove batteries if storing for extended periods to prevent leakage.

Rozwiązywanie problemów

If the Fluke 355 Clamp-Meter is not functioning as expected, consider the following:

  • Brak wyświetlacza/zasilania: Check if the batteries are correctly installed and have sufficient charge. Replace batteries if necessary. Ensure the rotary switch is not in the "OFF" position.
  • Niedokładne odczyty: Verify that the correct measurement function is selected. Ensure test leads are properly connected and not damaged. For current measurements, ensure the clamp jaws are fully closed around a single conductor.
  • Brzęczyk ciągłości nie działa: Ensure the device is in the continuity measurement mode and the circuit is de-energized.

For persistent issues, refer to the official Fluke support resources or contact customer service.

Specyfikacje

ParametrWartość
Maximum AC Current Input2,000A (1,400A RMS)
Maximum DC Current Input2,000A
Maksymalna objętość prądu przemiennegotage Wejście600 V
Maks. obj. prądu stałegotage Wejście1,000 V
Maximum Frequency Detected1kHz
Maximum Resistance Detected400kΩ
Ocena instalacjiCAT IV, 600V; CAT III, 1,000V
Spełnione standardyIEC safety standard 61010-2-032; CE marking; CSA; Australia N10140
Zasilacz(6) baterie AA 1.5 V
Waga0.814 kg / 1.8 funta
Wymiary (wys. x szer. x gł.)300 x 98 x 52 mm / 12 x 3.75 x 2 cala
Otwarcie szczęki58 mm (2.3 cali)
Automatyczne wyłączanie zasilania20 minut
WyświetlaczPodświetlany wyświetlacz LCD
Prawdziwy RMSTak
Automatyczne określanie zakresuTak
ProducentKorporacja Fluke
Numer modeluFLUKE-355
UPC095969401203, 785577871016

Gwarancja i wsparcie

Fluke Corporation provides high-quality testing tools. For warranty information, technical support, or service, please visit the official Fluke webstronie lub skontaktuj się z działem obsługi klienta.

Więcej informacji i zasobów pomocy znajdziesz na stronie Sklep Fluke na Amazonie.

Powiązane dokumenty - FLUKE-355

Przedview Fluke 381 Zdalny wyświetlacz True-rms Clamp Instrukcja obsługi miernika
Kompleksowa instrukcja obsługi zdalnego wyświetlacza Fluke 381 True-rms Clamp Miernik. Obejmuje funkcje produktu, procedury pomiaru prądu przemiennego/stałego, objętościtage, rezystancja, częstotliwość, prąd rozruchowy, konserwacja, specyfikacje i informacje dotyczące bezpieczeństwa. Zawiera szczegółowe opisy diagramów i tabel.
Przedview Fluke 373 True-RMS AC Clamp Licznik - Dane techniczne i więcejview
Szczegółowe dane techniczne, kluczowe cechy, opis produktuview, specyfikacje i informacje dotyczące zamawiania miernika Fluke 373 True-RMS AC Clamp Miernik przeznaczony do pomiaru prądu przemiennego do 600 A.
Przedview Fluke 323/324/325 Clamp Instrukcja obsługi miernika – dane techniczne i bezpieczeństwo
Kompleksowa instrukcja obsługi Fluke 323, 324 i 325 Clamp Liczniki. Zawiera informacje dotyczące bezpieczeństwa, specyfikacje elektryczne i mechaniczne oraz instrukcje obsługi.
Przedview Fluke 305 klamp Instrukcja obsługi miernika
User manual for the Fluke 305 Clamp Meter, providing detailed safety information, product specifications, and operational guidance for accurate electrical measurements.
Przedview Bezprzewodowy miernik AC/DC Fluke serii 370 FC True-RMSamp Instrukcja obsługi i specyfikacja mierników
Pełna instrukcja obsługi i specyfikacje techniczne bezprzewodowego miernika AC/DC Fluke serii 370 FC True-RMSamp Liczniki, w tym modele 374 FC, 375 FC i 376 FC. Funkcje, możliwości, tabele porównawcze i informacje o zamawianiu.
Przedview Cyfrowe multimetry kieszonkowe Fluke 106/107: dane techniczne i funkcje
Szczegółowe specyfikacje techniczne, najważniejsze cechy produktów i ogólne informacje o cyfrowych multimetrach Fluke 106 i 107 w formacie dłoni. Dowiedz się więcej o ich parametrach elektrycznych, dokładności, funkcjach i dołączonym wyposażeniu.