1. Wprowadzenie
This manual provides essential information for the safe installation, operation, and maintenance of your Marley M602W Qmark Electric Line Voltage Wall Thermostat. This device is designed for wall-mounted, heating-only applications and features double-pole operation with a distinct OFF position. Please read these instructions thoroughly before installation and use.
Główne cechy:
- Double-pole operation with a marked OFF position for enhanced safety.
- Snap action design for extended operational life.
- Temperature differential of 4 degrees Fahrenheit.
- Adjustable temperature range from 45°F to 75°F.
2. Ważne informacje dotyczące bezpieczeństwa
WARNING: Risk of electric shock. Installation must be performed by a qualified electrician in accordance with all local and national electrical codes. Disconnect power at the main service panel before installing or servicing this thermostat.
- Ensure the power supply matches the thermostat's voltage (277 V).
- Do not operate the thermostat with damaged wiring.
- Trzymaj termostat z dala od wody i nadmiernej wilgoci.
- This thermostat is intended for heating control only.
3. Instalacja (konfiguracja)
The Marley M602W thermostat is designed for wall mounting and direct wiring into a line voltage heating system. Proper installation is crucial for safe and effective operation.
Kroki instalacji:
- Odłączenie zasilania: Turn off power to the heating circuit at the main electrical panel before beginning installation. Verify power is off using a voltagtester.
- Miejsce montażu: Select an indoor wall location away from drafts, direct sunlight, and heat sources that could affect temperature readings. Mount at standard switch height.
- Okablowanie: Connect the thermostat's wires to your heating system's line voltage wiring. This is a double-pole thermostat, meaning it disconnects both sides of the 277V line when in the 'OFF' position. Ensure all connections are secure and comply with local electrical codes. Refer to the wiring diagram provided with the product packaging for specific connections (L1, L2, T1, T2).
- Bezpieczny termostat: Mount the thermostat securely to the wall box using the provided screws.
- Przywróć zasilanie: Once installation is complete and all connections are verified, restore power at the main electrical panel.

4. Instrukcja obsługi
The Marley M602W thermostat features a simple manual control for setting your desired room temperature.
Regulacja temperatury:
- Włączyć coś: Rotate the central dial clockwise from the 'OFF' position to your desired temperature setting. The thermostat will activate the heating system when the room temperature falls 4°F below the set point.
- Ustaw temperaturę: The dial is marked with temperature indicators from 45°F to 75°F. Rotate the dial to align with your preferred temperature.
- Wyłączyć coś: To completely turn off the heating system, rotate the dial counter-clockwise until it clicks into the 'OFF' position. This engages the double-pole disconnect feature.
5. Konserwacja
The Marley M602W thermostat requires minimal maintenance to ensure continued reliable operation.
- Czyszczenie: Okresowo przecieraj zewnętrzną część termostatu miękką, miękką szmatką.amp Ściereczką. Nie używaj środków czyszczących ani rozpuszczalników o działaniu ściernym. Upewnij się, że do obudowy termostatu nie dostanie się żaden płyn.
- Brak baterii: This thermostat is corded electric and does not require batteries.
- Kontrola: Annually inspect the thermostat for any visible damage or loose connections. If any issues are found, disconnect power and consult a qualified electrician.
6. Rozwiązywanie Problemów
If you experience issues with your Marley M602W thermostat, refer to the following common problems and solutions:
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Thermostat does not turn on/heating system is not active. | No power to the thermostat; thermostat set to 'OFF'; faulty wiring connection; tripped circuit breaker. | Check circuit breaker; ensure thermostat is not in 'OFF' position; verify power supply. If issues persist, consult a qualified electrician to check wiring. |
| Inaccurate temperature control or inconsistent heating. | Thermostat location affected by drafts or heat sources; internal component issue. | Ensure thermostat is not in a drafty area or near a heat source. If the issue continues, the thermostat may require replacement. |
| Knob feels loose or difficult to turn. | Mechanical wear or damage. | If the knob is loose or not functioning correctly, the thermostat may need to be replaced. |
| Thermostat does not work with 240V system. | Nieprawidłowa objętośćtage application or incompatible system. | This thermostat is rated for 277 Volts. Ensure your heating system's voltage matches this specification. Consult a qualified electrician for compatibility verification. |
7. Specyfikacje
| Funkcja | Szczegół |
|---|---|
| Marka | Marley |
| Nazwa modelu | M602W |
| Typ kontrolera | Push Button (Rotary Dial) |
| Funkcja specjalna | Temperature Display (via dial markings) |
| Kolor | Biały |
| Konkretne zastosowania | Commercial/Industrial Use, Hospital Settings, Home Healthcare |
| Rodzaj kontroli temperatury | Podręcznik |
| Technologia łączności | Przewodowy |
| Zawarte komponenty | Wall Thermostat & Controls |
| Źródło zasilania | Elektryczny przewodowy |
| Tomtage | 277 wolty |
| Tworzywo | Plastik, Stal nierdzewna |
| Typ wyświetlacza | Analog (dial markings) |
| Rodzaj wykończenia | Lśniący |
| Metoda kontroli | Tarcza obrotowa |
| Typ montażu | Montaż ścienny |
| Zakres temperatur | 45°F - 75°F |
| Różnicowy | 4°F |
| Waga przedmiotu | 8 uncji (0.5 funta) |
| Wymiary produktu | 2.25 x 2.56 x 4.63 cala |
| Certyfikaty | CSA, ul |
| UPC | 098319841513 |
8. Gwarancja i wsparcie
For warranty information and customer support regarding your Marley M602W thermostat, please consult the documentation included with your purchase or visit the official Marley website. You may also contact Marley customer service directly for assistance.
Marley Official Store: Visit the Marley Store on Amazon