1. Wprowadzenie
This manual provides essential instructions for the proper use and maintenance of your Hanna Instruments Groline Soil Test Direct Soil Conductivity Tester, model HI98331. Please read this manual thoroughly before operating the device to ensure accurate measurements and prolong the life of your instrument.

Figure 1: Hanna Instruments Groline Soil Test Direct Soil Conductivity Tester HI98331. This image shows the complete device, featuring a digital display and a long, slender probe for direct soil insertion.
2. Informacje dotyczące bezpieczeństwa
Always handle the instrument with care. Do not immerse the meter body in water. Keep the battery compartment dry. Store the device in a cool, dry place when not in use.
3. Składniki produktu
The HI98331 Groline Soil Test Direct Soil Conductivity Tester includes:
- HI98331 Meter with integrated soil probe
- Baterie CR2 (wstępnie zainstalowane)
- Instrukcja obsługi

Figure 2: Battery compartment. This image shows the rear of the meter with the battery cover removed, revealing the CR2 battery slot.
4. Konfiguracja i instalacja baterii
The HI98331 meter comes with batteries pre-installed. If replacement is necessary:
- Znajdź pokrywę komory baterii znajdującą się z tyłu miernika.
- Twist the cover counter-clockwise to remove it.
- Remove the old CR2 battery and insert a new one, observing polarity.
- Załóż pokrywę komory baterii i przekręć ją zgodnie z ruchem wskazówek zegara, aby ją zabezpieczyć.
Ensure the battery compartment is sealed tightly to prevent moisture ingress.
5. Instrukcja obsługi
Follow these steps for accurate bulk EC measurement using your HI98331 Direct Soil EC Meter:
- Prepare the Testing Location: Select the specific area in the soil where you wish to take a measurement.
- Wyczyść sondę: Rinse the testing probe thoroughly with deionized water. Gently wipe it dry with a clean, soft cloth.
- Moisten the Soil: Ensure the soil in the testing area is adequately moist. Dry soil will not yield accurate readings.
- Create an Insertion Hole: Use a ruler or an auger to create a pilot hole in the soil. This helps maintain consistent testing depth and prevents damage to the probe.
- Insert the Tester: Carefully insert the HI98331 soil conductivity tester directly into the prepared hole in the soil. Ensure good contact between the probe and the soil.
- Wykonaj pomiar: Wait for the reading on the digital display to stabilize. Record the displayed EC value.

Figure 3: Meter in operation. This image depicts the HI98331 meter with its probe inserted into soil, displaying a reading on its screen.
6. Kalibracja
For optimal accuracy, regular calibration of your HI98331 is recommended. Refer to the specific calibration instructions provided in the full product manual or on the manufacturer's website. Typically, calibration involves using standard EC solutions.
7. Konserwacja i przechowywanie
- Czyszczenie sondy: After each use, rinse the probe with deionized water to remove any soil residue. Do not use abrasive materials.
- Składowanie: Store the meter in a clean, dry environment. Ensure the probe is clean and dry before storage.
- Czas pracy baterii: Wymień baterie, gdy na wyświetlaczu pojawi się wskaźnik niskiego poziomu naładowania baterii.
8. Rozwiązywanie Problemów
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| No display/Meter does not turn on | Rozładowane baterie lub nieprawidłowa instalacja baterii. | Sprawdź biegunowość baterii; wymień baterie. |
| Niedokładne odczyty | Dirty probe, dry soil, or meter out of calibration. | Clean probe, moisten soil, perform calibration. |
| Błędne odczyty | Poor contact with soil, air bubbles, or damaged probe. | Re-insert probe firmly, ensure soil is moist, inspect probe for damage. |
9. Specyfikacje
| Parametr | Szczegół |
|---|---|
| Model | HI98331 |
| Zakres pomiaru | (Information not provided in source, typical for EC meters) |
| Rezolucja | (Information not provided in source) |
| Dokładność | (Information not provided in source) |
| Kompensacja temperatury | Automatyczna kompensacja temperatury (ATC) |
| Zasilacz | Bateria 1 x CR2 |
| Wymiary | 9.41 x 2.64 x 1.26 cala |
| Waga | 5.61 uncji |
10. Gwarancja i wsparcie
For warranty information and technical support, please refer to the official Hanna Instruments webOdwiedź stronę internetową lub skontaktuj się bezpośrednio z działem obsługi klienta. Zachowaj paragon jako dowód zakupu.
Producent: Instrumenty Hanny
Webstrona: www.hannainst.com