Fluke TL175

Instrukcja obsługi przewodów pomiarowych Fluke TL175 TwistGuard

Model: TL175

1. Wprowadzenie

The Fluke TL175 TwistGuard Test Leads are designed for electrical measurement applications, offering enhanced safety and versatility. These test leads feature an adjustable tip shroud mechanism and a WearGuard lead wire wear indication system, ensuring reliable performance and user safety across various measurement environments. They are compatible with all instruments that accept standard 4mm shrouded banana plugs.

2. Informacje dotyczące bezpieczeństwa

WARNING: To prevent possible electrical shock, fire, or personal injury:

  • Always use the test leads with the appropriate safety category rating for the measurement environment.
  • Inspect test leads for damage before each use. Do not use if insulation is damaged or if the inner contrasting color of the WearGuard system is exposed.
  • Ensure the test lead tips are fully inserted into the measurement device.
  • Nie stosować w ilości większej niż zalecana objętość.tage, as marked on the test leads.
  • Keep fingers behind the finger guards on the probes during measurements.
  • Zachowaj ostrożność podczas pracy z objętościątagpowyżej 30 V AC RMS, 42 V szczytowo lub 60 V DC. Te wartościtagStwarzają ryzyko porażenia prądem.

3. Funkcje produktu

  • TwistGuard Extendable Tip Shroud: Patented design allows users to twist the probe handle to extend or retract the tip shroud, reducing tip exposure for higher safety categories (CAT III, CAT IV) and providing full tip exposure for lower categories (CAT II).
  • WearGuard Lead Wire Indication: Each test lead features two layers of silicone insulation. If the outer layer is nicked or scuffed, the inner contrasting color becomes visible, indicating the need for replacement.
  • Double Insulated Silicone Leads: Designed to withstand high temperatures and maintain flexibility in cold conditions.
  • Extra-Heavy Duty Strain Relief: Reinforced strain relief on both probe-end and plug-end for enhanced durability, tested beyond 30,000 bends.
  • Universal Input Plugs: Compatible with all instruments that accept standard 4mm shrouded banana plugs.
  • Removable 4mm Lantern Tips: Includes removable tips that thread onto the lead tip for versatile connections.
Fluke TL175 TwistGuard Test Leads

Rysunek 1: Koniecview of Fluke TL175 TwistGuard Test Leads, showing the red and black leads with their respective probe tips and banana plugs.

4. Konfiguracja i instalacja

  1. Zbadaj potencjalnych klientów: Before connecting, visually inspect both test leads for any signs of damage, cuts, or exposed inner insulation. If damage is found, replace the leads immediately.
  2. Połącz z instrumentem: Insert the shrouded banana plugs (black for common, red for voltage/current) firmly into the corresponding input jacks of your multimeter or test instrument. Ensure a secure connection.
    Fluke TL175 Test Leads connected to a multimeter

    Figure 2: Fluke TL175 Test Leads properly connected to a digital multimeter.

  3. Adjust TwistGuard Shroud: The TwistGuard feature allows you to adjust the exposed tip length.
    • For CAT II measurements (e.g., wall outlets), twist the probe handle to fully expose the 19mm tip.
    • For CAT III or CAT IV measurements (e.g., circuit breaker panels, main service), twist the probe handle to retract the shroud, exposing only the 4mm tip for increased safety.
      Hand demonstrating the TwistGuard feature on a Fluke TL175 test lead

      Figure 3: A hand twisting the probe handle to adjust the TwistGuard tip shroud.

  4. Attach Lantern Tips (Optional): If your application requires a different connection type, the included 4mm lantern tips can be threaded onto the probe tips.

5. Instrukcja obsługi

Once properly connected and adjusted, the Fluke TL175 Test Leads function as standard test probes for your electrical measurements. Always refer to your multimeter's instruction manual for specific measurement procedures.

  • Tomtage Pomiar: Wybierz odpowiednią objętośćtage range on your multimeter. Ensure the TwistGuard shroud is set for the correct safety category. Place the black probe on the common or ground point and the red probe on the point to be measured.
  • Aktualny pomiar: For current measurements, ensure the red lead is connected to the correct current input jack on your multimeter (e.g., 10A or mA). The circuit must be broken to insert the meter in series.
  • Opór/Ciągłość: Select the resistance or continuity function. The leads can be used to test circuit continuity or component resistance.
Fluke TL175 Test Lead being used to measure in a circuit breaker panel

Figure 4: Using a Fluke TL175 Test Lead in a circuit breaker panel, demonstrating a CAT IV application with the shroud retracted.

Fluke TL175 Test Leads being used to test an electrical outlet

Figure 5: Fluke TL175 Test Leads used to test an electrical outlet, suitable for CAT II applications with tips fully exposed.

6. Konserwacja

  • Czyszczenie: Clean the test leads with a damp szmatką i łagodnym detergentem. Nie używaj ściernych środków czyszczących ani rozpuszczalników.
  • Kontrola: Regularly inspect the leads for any signs of wear or damage, especially the WearGuard insulation. If the inner contrasting color is exposed, the leads are compromised and should be replaced to maintain safety.
  • Składowanie: Store the test leads in a clean, dry environment, away from extreme temperatures and direct sunlight. Avoid sharp bends or kinks in the cables.

7. Rozwiązywanie Problemów

  • No Reading or Intermittent Reading:
    • Ensure the banana plugs are fully inserted into the multimeter.
    • Check for visible damage to the lead insulation or connectors.
    • Perform a continuity test on the leads themselves by touching the tips together. If no continuity, the leads may be internally broken and require replacement.
  • Niedokładne odczyty:
    • Verify the multimeter is set to the correct function and range.
    • Ensure the test lead tips are making good contact with the circuit points.
    • Check for corrosion or dirt on the probe tips or banana plugs.

8. Specyfikacje

FunkcjaSpecyfikacja
Numer modeluTL175
Ocena bezpieczeństwaCAT II 1000V, CAT III 1000V, CAT IV 600V, 10A maximum, Pollution Degree 2
Exposed Probe Tip Length19mm to 4mm (0.75" to 0.16") adjustable
Lead Wire MaterialDouble Insulated Silicone
Temperatura pracy-20 do 55 °C (-4 do 131 °F)
Wysokość2000 m (6,562')
ZgodnośćPN-EN61010-031
Wymiary produktu10 x 3 x 2 cala
Waga przedmiotu120 gramów (4.23 uncji)

Zawartość pudełka:

  • Fluke TL175 TwistGuard Test Leads (Red and Black)
  • Removable 4mm Lantern Tips

9. Gwarancja i wsparcie

The Fluke TL175 TwistGuard Test Leads come with a 1-year warranty from the date of purchase, covering defects in materials and workmanship. For warranty claims, technical assistance, or further information, please contact Fluke Corporation customer support or visit the official Fluke webstrona.

Producent: Korporacja Fluke

Data pierwszej dostępności: 1 czerwca 2011 r.

Powiązane dokumenty - TL175

Przedview Multimetr cyfrowy Fluke 179: Przewodnik po konserwacji i serwisie w terenie
Odkryj cyfrowy multimetr Fluke 179 True-RMS, zaprojektowany do efektywnej konserwacji instalacji elektrycznych i systemów HVAC. Dowiedz się więcej o jego funkcjach, specyfikacji i zalecanych akcesoriach do niezawodnej pracy w terenie.
Przedview Instrukcja obsługi multimetrów cyfrowych Fluke 15B+/17B+/18B+
Kompleksowa instrukcja obsługi multimetrów cyfrowych Fluke 15B+, 17B+ i 18B+, obejmująca funkcje, obsługę, bezpieczeństwo, konserwację i specyfikację. Dokument zawiera szczegółowe instrukcje dotyczące korzystania z multimetrów do różnych pomiarów elektrycznych.
Przedview Cyfrowe multimetry kieszonkowe Fluke 106/107: dane techniczne i funkcje
Szczegółowe specyfikacje techniczne, najważniejsze cechy produktów i ogólne informacje o cyfrowych multimetrach Fluke 106 i 107 w formacie dłoni. Dowiedz się więcej o ich parametrach elektrycznych, dokładności, funkcjach i dołączonym wyposażeniu.
Przedview Fluke 107 Ręczny multimetr cyfrowy CAT III – dane techniczne
Szczegółowe dane techniczne, funkcje i informacje ogólne dotyczące ręcznego multimetru cyfrowego Fluke 107 CAT III. Zawiera pomiary elektryczne, parametry bezpieczeństwa i szczegóły dotyczące zamówień.
Przedview Zestaw adapterów Fluke FEV100 do stacji ładowania pojazdów elektrycznych: dane techniczne i specyfikacje
Poznaj specyfikacje techniczne, funkcje i procedury testowania zestawu adapterów Fluke FEV100, zaprojektowanego do bezpiecznego i wydajnego testowania stacji ładowania pojazdów elektrycznych (EVSE). Zawiera informacje o bezpieczeństwie, zgodności i szczegóły dotyczące zamówień.
Przedview Multimetr Fluke 110 True-RMS: dane techniczne i funkcje
Szczegółowe specyfikacje i funkcje kompaktowego multimetru Fluke 110 True-RMS, zaprojektowanego do precyzyjnej instalacji elektrycznej i diagnostyki. Zawiera dane dotyczące dokładności, klas bezpieczeństwa i dołączone akcesoria.