1. Wprowadzenie
The Atrix Omega Green Supreme IPM H13 HEPA vacuum (Model: VACOMEGASIPM) is a specialized, portable vacuum designed for pest management professionals. It offers superior filtration and convenient features for efficient operation in various environments.
Główne cechy obejmują:
- Three levels of filtration, including an H13 HEPA filter.
- Self-storage compartment for accessories.
- Powerful 1,000-hour rated Ametek® Advantek II motor.
- 25-foot detachable power cord.
- Quiet operation at less than 70dB.

This manual provides detailed instructions for the safe and effective use, maintenance, and troubleshooting of your Atrix Omega Green Supreme vacuum.
2. Informacje dotyczące bezpieczeństwa
OSTRZEŻENIE: Ten produkt może narazić Cię na działanie substancji chemicznych, w tym ołowiu, o którym w stanie Kalifornia wiadomo, że powoduje raka i wady wrodzone lub inne uszkodzenia układu rozrodczego. Aby uzyskać więcej informacji, przejdź do www.P65Warnings.ca.gov.
Ogólne środki ostrożności:
- Always unplug the vacuum from the power outlet before performing any maintenance, cleaning, or when not in use.
- Do not use the vacuum on wet surfaces or to pick up liquids. This vacuum is designed for dry pick-up only.
- Nie zbieraj materiałów łatwopalnych, gorącego popiołu ani ostrych przedmiotów.
- Trzymaj włosy, luźne ubrania, palce i inne części ciała z dala od otworów i ruchomych części.
- Używaj wyłącznie zgodnie z opisem w niniejszej instrukcji. Używaj wyłącznie akcesoriów zalecanych przez producenta.
- Do not operate the vacuum with a damaged cord or plug. If the vacuum is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return it to a service center.
- Nie ciągnij ani nie przenoś za sznurek, nie używaj sznura jako uchwytu, nie zamykaj drzwi na sznurze ani nie ciągnij za ostre krawędzie lub rogi. Trzymaj przewód z dala od gorących powierzchni.
- Nie odłączaj, ciągnąc za przewód. Aby odłączyć, chwyć za wtyczkę, nie za przewód.
- Nie dotykaj wtyczki ani odkurzacza mokrymi rękami.
- Urządzenie to nie jest przeznaczone do użytku przez osoby (w tym dzieci) o ograniczonej sprawności fizycznej, sensorycznej lub umysłowej, a także osoby nieposiadające odpowiedniego doświadczenia lub wiedzy, chyba że znajdują się one pod nadzorem osoby odpowiedzialnej za ich bezpieczeństwo lub otrzymały od niej instrukcje dotyczące korzystania z urządzenia.
3. Zawartość opakowania
Sprawdź, czy w opakowaniu znajdują się wszystkie komponenty:
- Atrix Omega Green Supreme Vacuum Unit
- Instrukcja obsługi (niniejsza instrukcja)
- 5.6" Clear Hose
- Ground Brush
- 3 Wands with Caps
- Pasek na ramię
- Filtr HEPA (wstępnie zainstalowany lub osobny)
4. Instalacja i montaż
4.1 Podłączanie węża
- Locate the hose connection port on the side of the vacuum unit.
- Insert the larger end of the 5.6" clear hose firmly into the connection port until it clicks into place.

4.2 Assembling Wands and Attachments
- Connect the desired wand sections together by twisting them firmly.
- Attach the ground brush or other desired accessory (e.g., crevice tool) to the end of the assembled wand.
- Insert the smaller end of the hose into the open end of the wand assembly.
4.3 Połączenie zasilania
- Ensure the vacuum's power switch is in the "OFF" position.
- Connect the detachable 25-foot power cord to the power inlet on the vacuum unit.
- Podłącz przewód zasilający do standardowego gniazdka elektrycznego 120 V AC.

5. Instrukcja obsługi
5.1 Włączanie/wyłączanie
To turn the vacuum on, locate the power switch on the unit and flip it to the "ON" position. To turn it off, flip the switch back to the "OFF" position.
5.2 Korzystanie z odkurzacza
- Once powered on, guide the attached wand and accessory over the area to be cleaned.
- The vacuum's powerful suction will collect dust, debris, and pests into the HEPA filter system.
- For hands-free operation, attach the included shoulder strap to the designated loops on the vacuum unit.

The HEPA filter is 99.97% efficient at 0.3 microns, effectively capturing a wide range of particles including bed bugs, cockroaches, rodent droppings, dry chemicals, and hazardous materials.
6. Konserwacja
6.1 Wymiana filtra HEPA
The 1-gallon HEPA filter is designed for immediate containment and should be replaced when suction power decreases significantly or when the filter appears full. The filter includes three layers of 56 pleat media (one cellulose, two glass layers).
- Upewnij się, że odkurzacz jest odłączony od gniazdka elektrycznego.
- Open the vacuum unit to access the filter compartment (refer to Figure 3).
- Carefully remove the old HEPA filter, ensuring not to dislodge any captured debris.
- Dispose of the old filter according to local regulations for hazardous waste, if applicable.
- Insert a new Atrix replacement HEPA filter, ensuring it is seated correctly.
- Close the vacuum unit securely.
6.2 Cleaning the Unit and Accessories
- Przetrzyj zewnętrzną część jednostki odkurzacza za pomocąamp płótno. Nie używaj ostrych środków chemicznych ani ściernych środków czyszczących.
- Clean the hose and accessories as needed. Ensure they are dry before reattaching.
- Before transport or storage, utilize the hose and filter plugs to prevent any pests or debris from escaping or spilling out.
7. Rozwiązywanie Problemów
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Odkurzacz się nie włącza. | No power to the unit; power cord not fully plugged in; power switch off. | Check power outlet; ensure power cord is securely plugged into both the unit and the wall; confirm power switch is in "ON" position. |
| Zmniejszone ssanie. | Full or clogged HEPA filter; clogged hose or attachment; hose not securely attached. | Replace HEPA filter; check hose and attachments for blockages and clear them; ensure hose is firmly connected to the unit and wand. |
| Nietypowy dźwięk podczas pracy. | Foreign object in hose or attachment; motor issue. | Turn off and unplug the vacuum. Inspect hose and attachments for obstructions and remove them. If noise persists, contact customer support. |
8. Specyfikacje
| Funkcja | Szczegół |
|---|---|
| Marka | Atrix |
| Nazwa modelu | VACOMEGASIPM |
| Kolor | Zielony |
| Wymiary produktu | 20.25" dł. x 7.75" szer. x 10.75" wys. |
| Waga przedmiotu | 12.1 funta |
| Cotage | 628 watów |
| Ampwymazać | 5.23 Amps |
| Tomtage | 120 woltów |
| Typ filtra | HEPA Filter (99.97% at .3 micron) |
| Pojemność | 1 gallon (filter) |
| Długość węża | 1.8 metra (ok. 5.9 stóp) |
| Poziom hałasu | 70dB |
| Cechy specjalne | Portable, corded, HEPA filtration, Bagless |
| Metoda kontroli | Głos (Note: This specification from source data may refer to a feature not typically associated with this type of vacuum, likely a manual switch) |
| UPC | 838067000486 |
9. Gwarancja i wsparcie
9.1 Informacje o gwarancji
Atrix products are manufactured to high-quality standards. For specific warranty details regarding your Atrix Omega Green Supreme vacuum, please refer to the warranty card included with your purchase or visit the official Atrix webZachowaj paragon jako dowód zakupu na wypadek reklamacji.
9.2 Obsługa klienta
If you encounter any issues not covered in the troubleshooting section or require further assistance, please contact Atrix customer support. Contact information can typically be found on the Atrix webmiejscu lub na opakowaniu produktu.
You can also find a digital version of the user manual here: Atrix Omega Green Supreme User Manual (PDF)
10. Filmy produktowe