Extech PH110 Waterproof ExStik pH Meter Instruction Manual

Brand: Extech | Model: PH110

1. Wprowadzenie

The Extech PH110 Waterproof ExStik pH Meter is designed for accurate pH measurements in various substances. This device features a refillable pH electrode, allowing for extended use and consistent accuracy by replenishing the reference solution. Its robust, waterproof design ensures reliability in diverse environments.

2. Główne cechy

  • Refillable pH electrode for extended service life.
  • Analog bargraph display on LCD for trend indication.
  • Waterproof construction to IP57 standard.
  • Automatic 1, 2, or 3 point calibration with buffer solution recognition.
  • Flat Surface Electrode capable of measuring pH in liquids, semi-solids, and solids.

3. Zawartość opakowania

The Extech PH110 Waterproof ExStik pH Meter package includes:

  • Extech PH110 pH Meter with refillable pH electrode
  • 1.5mL bottle of KCI (Potassium Chloride) solution
  • Two reference junctions
  • Two electrode removal tools
  • Czapka ochronna
  • Sampfiliżanka
  • Four 3V CR-2032 batteries (pre-installed or included separately)
  • Pasek na szyję o długości 48 cali (1.2 m)

4. Konfiguracja

4.1 Instalacja baterii

  1. Upewnij się, że miernik jest wyłączony.
  2. Zlokalizuj komorę baterii.
  3. Insert four 3V CR-2032 Lithium Metal batteries, observing correct polarity.
  4. Dokładnie zamknij komorę baterii.

4.2 Electrode Preparation

  1. Zdejmij nasadkę ochronną z elektrody.
  2. Rinse the electrode tip with distilled water.
  3. If the electrode appears dry, soak it in electrode storage solution or pH 7 buffer for at least 30 minutes before first use.

5. Działanie

5.1 Kalibracja

Calibration is essential for accurate measurements. The PH110 supports 1, 2, or 3 point calibration and automatically recognizes buffer solutions.

  1. Turn on the meter by pressing the WŁ./WYŁ. przycisk.
  2. Prepare fresh pH buffer solutions (e.g., pH 4, 7, and 10). These are sold separately.
  3. Naciśnij i przytrzymaj CAL button until 'CAL' appears on the display.
  4. Immerse the electrode into the first buffer solution (e.g., pH 7). The meter will automatically recognize the buffer and calibrate. Wait for the reading to stabilize.
  5. For 2 or 3 point calibration, rinse the electrode with distilled water and immerse it into the next buffer solution (e.g., pH 4, then pH 10). The meter will continue to calibrate automatically.
  6. Ensure the display shows 'CAL' during the calibration process.

5.2 Pomiar

The flat surface electrode allows for versatile measurements.

  1. After calibration, rinse the electrode with distilled water.
  2. Zanurz elektrodę w sample to be measured. For liquids, ensure the electrode tip is fully submerged. For semi-solids or solids, ensure good contact with the flat surface electrode.
  3. Allow the reading to stabilize on the display. The analog bargraph will indicate trends in acidity or alkalinity.
  4. To switch between pH and temperature display modes, press the TRYB przycisk.
  5. Po dokonaniu pomiaru należy dokładnie opłukać elektrodę wodą destylowaną i założyć osłonę.
Extech PH110 Waterproof ExStik pH Meter displaying a pH reading.

Rysunek 1: The Extech PH110 pH meter, a handheld device with a digital display showing pH and temperature readings. It features three control buttons: MODE, CAL, and ON/OFF.

6. Konserwacja

6.1 Electrode Refilling

The refillable electrode design allows for prolonged accuracy and lifespan.

  1. When the reference solution depletes or accuracy declines, use the provided removal tools to access the reference junctions.
  2. Carefully refill the electrode with the 1.5mL KCI solution.
  3. Ensure the reference junctions are properly re-seated after refilling.
Hands refilling the Extech PH110 pH meter electrode with filling solution.

Rysunek 2: Zbliżenie view of hands refilling the Extech PH110 pH meter's electrode module with a specialized electrode filling solution from a small bottle. This process ensures the meter's continued accuracy and extends electrode life.

6.2 Czyszczenie i przechowywanie

  • Always rinse the electrode with distilled water after each use to prevent contamination.
  • The flat surface electrode is designed for easy cleaning. Gently wipe with a soft cloth if necessary.
  • Store the electrode with its protective cap filled with electrode storage solution (or pH 7 buffer if storage solution is unavailable) to keep the sensor hydrated. Do not store dry.

7. Rozwiązywanie Problemów

If the meter exhibits inaccurate readings or operational issues, consider the following:

  • Niedokładne odczyty: Recalibrate the meter using fresh buffer solutions. Ensure the electrode is clean and properly hydrated. Check if the reference solution in the electrode needs refilling.
  • Brak wyświetlacza/problemy z zasilaniem: Verify that the batteries are correctly installed and have sufficient charge. Replace batteries if necessary.
  • Powolna reakcja: The electrode might be dry or contaminated. Clean and rehydrate the electrode, then recalibrate.

8. Specyfikacje

SpecyfikacjaSzczegół
ProducentWydobycie
Numer częściPH110
Waga przedmiotu3.87 uncji
Wymiary produktu6.8 x 1.6 x 1.4 cala
Numer modelu przedmiotuPH110
Baterie4 Lithium Metal batteries (CR-2032) required (included)
Źródło zasilaniaZasilany bateryjnie
Stopień wodoodpornościNorma IP57
Kalibrowanie1, 2, or 3 point automatic buffer recognition
Typ elektrodyRefillable Flat Surface Electrode

9. Informacje o gwarancji

Extech provides a full one-year warranty on parts and workmanship for the PH110 pH Meter, unless otherwise specified. This warranty does not cover defects resulting from user actions such as misuse, improper wiring, operation outside of specified parameters, improper maintenance or repair, or unauthorized modifications.

10. Wsparcie

For further assistance, technical support, or to purchase accessories and replacement parts, please refer to the official Extech Instruments weblub skontaktuj się z działem obsługi klienta. Dane kontaktowe zazwyczaj znajdują się na opakowaniu producenta lub webstrona.

Powiązane dokumenty - PH110

Przedview Instrukcja obsługi wodoodpornych mierników pH Extech ExStik™ PH100 ​​i PH110
Kompleksowa instrukcja obsługi wodoodpornych mierników pH Extech ExStik™, modele PH100 ​​i PH110. Dowiedz się więcej o obsłudze, kalibracji, konserwacji i specyfikacji.
Przedview Instrukcja obsługi wodoodpornych mierników pH Extech ExStik PH100 ​​i PH110
Kompleksowa instrukcja obsługi wodoodpornych mierników pH Extech ExStik, modele PH100 ​​i PH110. Zawiera szczegółowe instrukcje dotyczące obsługi, kalibracji, konserwacji elektrod, wymiany baterii, środków ostrożności, specyfikacji i rozwiązywania problemów dla tych precyzyjnych urządzeń do pomiaru pH.
Przedview Instrukcja obsługi miernika przewodności, TDS, zasolenia i temperatury Extech ExStik II EC400
Kompleksowa instrukcja obsługi miernika Extech ExStik II EC400, szczegółowo opisująca funkcje pomiaru przewodności, całkowitej zawartości substancji rozpuszczonych (TDS), zasolenia i temperatury. Zawiera informacje dotyczące konfiguracji, obsługi, kalibracji, konserwacji, rozwiązywania problemów i specyfikacji.
Przedview Extech Comprehensive Catalog: Environmental Meters, Anemometers, and Test Equipment
Explore Extech's extensive range of high-quality environmental meters, thermo-anemometers, gas detectors, water quality testers, sound meters, light meters, and other precision test and measurement instruments designed for industrial, HVAC/R, and professional applications.
Przedview Extech PH220 Waterproof Palm pH Meter User Manual
User manual for the Extech PH220 Waterproof Palm pH Meter. Covers introduction, meter description, operation, calibration, measurement, storage, battery replacement, maintenance, troubleshooting, and specifications.
Przedview Instrukcja obsługi miernika wilgotności, temperatury, przepływu powietrza i światła EXTECH 45170 4 w 1
Instrukcja obsługi miernika EXTECH 45170, 4-w-1 mierzącego wilgotność, temperaturę, przepływ powietrza i oświetlenie. Zawiera informacje dotyczące obsługi, specyfikacji i gwarancji.