1. Koniec produktuview
The CyberPower CP1000PFCLCD is a mini-tower Uninterruptible Power Supply (UPS) system designed to provide battery backup, power protection, and surge protection. It features sine wave output, making it compatible with active Power Factor Correction (PFC) and conventional power supplies. This UPS safeguards desktop computers, workstations, networking devices, and home entertainment systems.
- 1000VA/600W PFC Sine Wave Battery Backup: Designed to support active PFC and conventional power supplies, safeguarding computers, workstations, network devices, and telecom equipment.
- 10 gniazd NEMA 5-15R: Includes five battery backup & surge protected outlets and five surge protected outlets. Input is a NEMA 5-15P right-angle, 45-degree offset plug with a five-foot power cord. Two USB charge ports (1 Type-A, 1 Type-C) are included for quick charging of mobile phones and tablets.
- Multifunction, Color LCD Panel: Displays immediate, detailed information on battery and power conditions. The color display alerts users to potential issues before they can affect critical equipment and cause downtime. The screen tilts up to 22 degrees for optimal viewing.
- Automatyczna objętośćtage Rozporządzenie (AVR): Corrects minor power fluctuations without switching to battery power, thereby extending the life of the battery.
2. Instrukcje konfiguracji
- Rozpakuj UPS: Ostrożnie wyjmij UPS z opakowania. Sprawdź, czy nie ma uszkodzeń powstałych podczas transportu.
- Podłącz akumulator: The UPS is shipped with the battery disconnected. Refer to the battery compartment instructions (usually located at the bottom or side panel) to connect the internal battery.
- Opłata początkowa: Plug the UPS into a standard 120V AC outlet. Allow the unit to charge for at least 8 hours before connecting any equipment to ensure maximum battery runtime.
- Podłącz sprzęt:
- Plug critical equipment (e.g., computer, monitor, network router) into the Zasilanie bateryjne i gniazda z ochroną przeciwprzepięciową. Te gniazdka zapewniają zasilanie podczastagi chronią przed przepięciami.
- Podłącz niekrytyczny sprzęt (np. drukarkę, skaner) do Gniazda z ochroną przeciwprzepięciowąGniazdka te zapewniają jedynie ochronę przeciwprzepięciową.
- Connect USB Charging Devices: Use the USB-A and USB-C ports on the front panel to charge compatible mobile devices.
- Włączanie: Naciśnij przycisk zasilania na panelu przednim, aby włączyć UPS. Wyświetlacz LCD się podświetli.
3. Instrukcja obsługi
- LCD Display Navigation: Use the 'Display', 'Mute', and 'Setup' buttons on the front panel to navigate through the LCD display. The display provides real-time information such as input/output voltage, battery capacity, estimated runtime, and load level.
- Moctage: Podczas zasilaniatage, the UPS will automatically switch to battery power. An audible alarm will sound (if not muted) and the LCD display will indicate battery mode.
- Muting the Alarm: Press the 'Mute' button to silence the audible alarm during a power outage.
- Bezpieczne wyłączenie: If a prolonged power outage occurs, safely shut down connected equipment before the UPS battery is depleted. The estimated runtime displayed on the LCD panel can help you manage this.
- Automatyczne ponowne uruchomienie: When utility power is restored, the UPS will automatically switch back to AC power and begin recharging its battery. Connected equipment will resume normal operation.
4. Konserwacja
- Wymiana baterii: The internal battery is user-replaceable. Refer to the manufacturer's guidelines for recommended replacement intervals (typically every 3-5 years, or when the UPS indicates a battery fault). Always use genuine CyberPower replacement batteries.
- Czyszczenie: Regularly clean the exterior of the UPS with a soft, dry cloth. Do not use liquid or aerosol cleaners. Ensure ventilation openings are free from dust and debris.
- Składowanie: If storing the UPS for an extended period, ensure the battery is fully charged. Recharge the battery every 3 months to prevent permanent damage. Store in a cool, dry place.
Battery Replacement Video
This video demonstrates the process of replacing batteries in a CyberPower UPS unit. It shows how to access the battery compartment, disconnect the old batteries, and install new ones. The video highlights the importance of careful handling of the LCD panel connection and proper terminal re-connection. It also mentions the use of ExpertPower 12V batteries as replacements.
5. Rozwiązywanie Problemów
- UPS się nie włącza: Ensure the power cord is securely plugged into a wall outlet and the UPS. Verify the internal battery is properly connected. Allow for initial charging if it's a new unit.
- Krótki czas pracy baterii: The battery may be old and require replacement, or it may not be fully charged. Ensure the UPS has been charged for at least 8 hours. Reduce the load on the battery backup outlets.
- Alarm przeciążenia: If the UPS emits a continuous alarm and the LCD indicates an overload, disconnect non-essential equipment from the battery backup outlets until the alarm stops.
- Brak prądu w gniazdkach: Check the circuit breaker on the back of the UPS. Press it to reset if it has tripped. Ensure the UPS is turned on.
6. Specyfikacje
| Wymiary produktu | 10.24" gł. x 3.94" szer. x 9.7" wys. |
| Waga przedmiotu | 15.9 funta |
| Numer modelu przedmiotu | CP1000PFCLCDA |
| Baterie | Wymagana 1 bateria 12 V (w zestawie) |
| Marka | Cybermoc |
| Skład ogniw baterii | Uszczelnione kwasowo-ołowiowe |
| Tomtage | 120 wolty |
| Kolor | Czarny |
| Data pierwszej dostępności | 8 września 2010 r. |
7. Gwarancja i wsparcie
CyberPower CP1000PFCLCD jest wyposażony w 3-letnia gwarancja, w tym bateria. Dodatkowo jest wspierany przez Gwarancja na podłączony sprzęt o wartości 300 000 USD and includes FREE PowerPanel Personal Edition Management Software (available for download).
For technical support, troubleshooting assistance, or warranty claims, please visit the official CyberPower webOdwiedź witrynę lub skontaktuj się z działem obsługi klienta. Zachowaj paragon i numer seryjny produktu, aby szybciej uzyskać pomoc.
8. Wizualizacje produktów

Opis obrazu: Przód view of the CyberPower CP1000PFCLCD UPS. The unit is black with a prominent LCD display showing input voltage and battery status. USB-A and USB-C charging ports are visible below the display. The CyberPower logo and '1000VA' are printed at the bottom.

Opis obrazu: Szczegółowy view of the back panel of the CyberPower CP1000PFCLCD UPS. It features five battery backup and surge-protected outlets on the left, and five surge-protected outlets on the right. Various communication ports including Network (In/Out), USB, and Serial are visible at the top, along with a circuit breaker button.

Opis obrazu: This image presents both the front and back views of the CyberPower CP1000PFCLCD UPS side-by-side. The front shows the LCD display and USB ports, while the back highlights the arrangement of the 10 NEMA 5-15R outlets and various data ports, emphasizing the compact mini-tower design.

Opis obrazu: An image illustrating the physical dimensions of the CyberPower CP1000PFCLCD UPS. Key measurements for height (9.70 inches), width (3.90 inches), and depth (10.20 inches) are clearly indicated, showcasing its mini-tower form factor.

Opis obrazu: The CyberPower CP1000PFCLCD UPS is shown discreetly placed within a modern home entertainment setup, next to a gaming console and television. The image demonstrates how the compact mini-tower design allows it to blend into various environments while providing power protection.

Opis obrazu: A graphic titled "PROFESSIONAL POWER PROTECTION PFC SINEWAVE UPS SYSTEMS". It lists various power issues the system protects against, including Blackouts, Sags, Spikes, Under Voltages, and Over Voltages, with a background image of a person working at a computer.
9. Oficjalny film o produkcie
Opis filmu: This official product video from CyberPower Systems Direct provides an overview of the CyberPower PFC Compatible Pure Sine Wave Tower UPS. It highlights the key features and benefits of the UPS, including its pure sine wave output for sensitive electronics, automatic voltage regulation, and multiple outlets for comprehensive power protection. The video showcases the unit's design and its role in maintaining continuous power for connected devices.