Leviton T5820-W

Lewiton 20 Amp TampInstrukcja obsługi gniazda dupleksowego odpornego na zakłócenia T5820-W

Brand: Leviton | Model: T5820-W

1. Wprowadzenie

The Leviton T5820-W 20 Amp Tamper-Resistant Duplex Outlet is designed for reliable performance in residential and commercial settings. Its impact-resistant thermoplastic construction ensures durability and a long service life. This outlet features a 20 Amp, 125 Volt rating, is tamper-resistant, straight blade, residential grade, and self-grounding.

Główne cechy:

  • TampOdporny na er: Provides protection from electrical shocks by preventing insertion of foreign objects.
  • Trwała konstrukcja: Made from impact-resistant thermoplastic nylon for extended service life.
  • Łatwa instalacja: Designed with side wiring for straightforward setup.
  • Zgodność z NEC: Features a TR symbol on the strap, confirming compliance with the latest National Electrical Code requirements.
Przód i tył view of the Leviton T5820-W 20 Amp Tamper-Resistant Duplex Outlet, showing the white face and the wiring terminals.

Rysunek 1: Przód i tył view of the Leviton T5820-W Duplex Outlet, highlighting its design and wiring terminals.

2. Informacje dotyczące bezpieczeństwa

OSTRZEŻENIE: To avoid fire, shock, or death, always turn OFF power at the circuit breaker or fuse box before wiring. Installation should be performed by a qualified electrician if you are unsure about the process. Use this device with copper wire only.

Ostrzeżenie dotyczące propozycji 65: Ten produkt może narazić Cię na działanie substancji chemicznych, w tym ołowiu, który jest znany w stanie Kalifornia jako czynnik powodujący raka i wady wrodzone lub inne szkody reprodukcyjne. Aby uzyskać więcej informacji, przejdź do www.P65Warnings.ca.gov.

3. Co znajduje się w pudełku

  • Leviton T5820-W 20 Amp Tamper-Resistant Duplex Outlet (White)

4. Instalacja

Czynności poprzedzające instalację:

  1. Wyłącz zasilanie na wyłączniku automatycznym lub skrzynce bezpieczników.
  2. Usuń istniejącą płytę ścienną i gniazdko.
  3. Carefully disconnect the wires from the old outlet, noting their connections (hot, neutral, ground).

Metody okablowania:

The Leviton T5820-W outlet supports Quickwire terminations and traditional side wiring. Always ensure connections are secure.

Quickwire Termination:

For Quickwire terminations, only 14-gauge solid copper wire is permitted by UL standards. Insert the stripped end of the 14-gauge solid copper wire into the Quickwire hole until it is firmly seated.

Side Wiring:

For larger than 14-gauge wire or stranded wire, use the side wiring method. Wrap the stripped end of the wire clockwise around the appropriate terminal screw (brass for hot, silver for neutral, green for ground) and tighten the screw securely.

Okablowanie tylne:

If available on your specific model, back wiring involves inserting the stripped wire into a hole next to the screw and tightening the screw to clamp the wire. This method is also suitable for larger gauge or stranded wires.

Video 1: Leviton Answer Series - Quickwire Terminations. This video provides a visual guide on how to properly use Quickwire terminations, emphasizing the requirement for 14-gauge solid copper wire and demonstrating alternative wiring methods like side wiring for other wire types.

Czynności po instalacji:

  1. Once wired, carefully push the outlet back into the wall box.
  2. Secure the outlet to the wall box with the mounting screws.
  3. Zainstaluj płytę ścienną.
  4. Przywróć zasilanie na wyłączniku lub skrzynce bezpieczników.
  5. Test the outlet to ensure proper function.
Leviton T5820-W 20 Amp Tamper-Resistant Duplex Outlet installed with a white wall plate.

Figure 2: The Leviton T5820-W Duplex Outlet shown installed with a standard white wall plate.

5. Działanie

The Leviton T5820-W Tamper-Resistant Duplex Outlet functions as a standard electrical receptacle. To use, simply insert a compatible electrical plug into either of the two outlets. The tamper-resistant shutters will open only when a two-pronged or three-pronged plug is inserted simultaneously, providing an added layer of safety.

6. Konserwacja

This outlet requires minimal maintenance. To clean, ensure power is off at the circuit breaker. Wipe the surface with a soft, damp ściereczką. Nie używaj środków czyszczących o właściwościach ściernych ani rozpuszczalników, ponieważ mogą one uszkodzić wykończenie lub elementy wewnętrzne.

7. Rozwiązywanie Problemów

Gniazdo nie zapewnia zasilania:

  • Sprawdź wyłącznik automatyczny: Ensure the circuit breaker supplying power to the outlet is in the "ON" position. If it has tripped, reset it.
  • Sprawdź okablowanie: If the issue persists, turn off power at the breaker and re-check all wire connections to ensure they are secure and correctly installed.
  • Skonsultuj się z elektrykiem: If you are unable to resolve the issue, contact a qualified electrician for assistance.

Difficulty Inserting Plug:

  • This is a feature of the tamper-resistant design. Ensure you are inserting the plug straight and applying even pressure to both prongs simultaneously.

8. Specyfikacje

FunkcjaSzczegół
Numer modeluT5820-W
MarkaLewiton
Tomtage125 wolty
Ampwymazać20 Amp
KolorBiały
TworzywoThermoplastic Nylon
Wymiary produktu4 x 2 x 2 cala
Waga przedmiotu1.76 uncji
Kompatybilne urządzeniaWszystko
Data pierwszej dostępności1 kwietnia 2010 r.

9. Gwarancja i wsparcie

Specific warranty information for the Leviton T5820-W outlet was not provided in the source data. For detailed warranty terms, technical support, or further assistance, please visit the official Leviton webstronie lub skontaktuj się z działem obsługi klienta.

Powiązane dokumenty - T5820-W

Przedview Instalacja i testowanie inteligentnego gniazdka GFCI Leviton: kompleksowy przewodnik
Instrukcja krok po kroku dotycząca instalacji i testowania gniazd Leviton Smart GFCI (modele D2GF1, D2GF2). Dowiedz się więcej o działaniu GFCI, okablowaniu, rozwiązywaniu problemów i środkach ostrożności.
Przedview Instrukcja obsługi gniazdka Leviton Decora Smart Z-Wave (ZW15R)
Kompleksowy przewodnik po instalacji, konfiguracji i dostosowywaniu urządzenia Leviton Decora Smart Z-Wave TampGniazdo odporne na zakłócenia (ZW15R). Dowiedz się więcej o funkcjach Z-Wave, integracji z siecią i bezpieczeństwie.
Przedview Instrukcja instalacji i obsługi gniazda Leviton GFCI z portami USB
Kompleksowy przewodnik dotyczący instalacji i obsługi gniazdek Leviton GFCI z portami USB, obejmujący instrukcje dotyczące okablowania, ostrzeżenia dotyczące bezpieczeństwa, procedury testowe i informacje gwarancyjne.
Przedview Instrukcja instalacji i testowania gniazda GFCI Leviton SmartlockPro
Kompleksowy przewodnik po instalacji i testowaniu gniazd Leviton SmartlockPro z wyłącznikiem różnicowoprądowym (GFCI). Obejmuje środki ostrożności, okablowanie, rozwiązywanie problemów i funkcje produktu.
Przedview Instrukcja instalacji i testowania gniazdka Leviton GFCI
Kompleksowy przewodnik na temat instalacji i testowania gniazdka GFCI Leviton SmartLock Pro, obejmujący instrukcje dotyczące okablowania, środki ostrożności i wskazówki dotyczące rozwiązywania problemów.
Przedview Przewodnik po wyborze przełączników klasy komercyjnej i przemysłowej Leviton
Kompleksowy przewodnik firmy Leviton, w którym szczegółowo opisano przełączniki klasy komercyjnej i przemysłowej, w tym przełączniki dźwigniowe, Decora Plus, Lev-lok, antybakteryjne i specjalistyczne, wraz ze szczegółami zastosowań i schematami okablowania.