Leviton 24W49

Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug

Model 24W49 Instruction Manual

1. Koniec produktuview

The Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug (Model 24W49) is a robust wiring device designed for demanding industrial environments. This plug features a polarized, grounding, L6-15P configuration with 3 wires, rated for 250V AC and 15 Amps. It is constructed from EPTR rubber material in a yellow color, ensuring water-tight performance and resistance to various harsh conditions. The Wetguard line meets IP67 and NEMA ratings for water ingress protection, offering superior durability and reliability.

Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug, Model 24W49

Figure 1: Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug (Model 24W49)

2. Główne cechy

  • Industrial Grade Construction: Zaprojektowane tak, aby wytrzymać trudne warunki przemysłowe.
  • Watertight and Dust-tight: Meets IP67 and NEMA ratings for protection against water and dust ingress.
  • Trwały materiał: Made from EPTR rubber, resistant to water, acids, alkalis, lubricants, cleaners, and solvents.
  • Odporność na korozję: Blades, contacts, terminal screws, and wiring clamps are electroless nickel-coated brass.
  • Łatwe okablowanie: Deep wire wells in the wiring module facilitate easier wiring.
  • Kontrola wizualna: Clear housing aids in inspecting for proper wire insertion and connection.
  • Bezpieczne połączenie: Patented compression nut and strain relief system ensure integrity of both the watertight seal and electrical connection.
  • Konfiguracja: L6-15P, 2-pole, 3-wire grounding.
  • Certyfikaty: UL 498, CSA C22.2, NOM 057 approved.

3. Specyfikacje

SpecyfikacjaWartość
Numer modelu24W49
Ampwymazać15 Amps
Tomtage250 wolty
Format wtyczkiType A (L6-15P)
Liczba przewodów3
Liczba słupów2
GruntTak
TworzywoEPTR Rubber
KolorŻółty
Cord Size Compatibility0.234 do 0.687 cala
Wymiary produktu1.44 x 1.3 x 3.54 cala
Waga przedmiotu3.2 uncji
CertyfikatyUL 498, CSA C22.2, NOM 057

4. Informacje dotyczące bezpieczeństwa

Always follow local electrical codes and regulations when installing or servicing electrical devices. Improper installation or use can result in serious injury or death. Disconnect power at the circuit breaker or fuse box before working on any electrical wiring.

  • Ensure the power supply is OFF before installation or maintenance.
  • Stosuj odpowiedni sprzęt ochrony osobistej (PPE), taki jak okulary ochronne i rękawice termoizolacyjne.
  • Verify correct wiring polarity and grounding connections.
  • Nie przekraczaj określonej objętościtagi i ampoceny bezpieczeństwa urządzenia.
  • Keep the device clean and free from debris to maintain its watertight integrity.
  • If the device shows signs of damage, discontinue use and replace it immediately.

5. Instalacja

This section outlines the general steps for wiring the Leviton Wetguard Locking Plug. For detailed wiring diagrams and specific instructions, refer to the packaging or consult a qualified electrician.

  1. Przygotuj kabel: Strip the outer jacket of the cable to the appropriate length, exposing the insulated conductors. Strip the insulation from each conductor.
  2. Zdemontuj wtyczkę: Unscrew the compression nut and separate the plug housing components.
  3. Włóż kabel: Feed the prepared cable through the compression nut and into the plug housing.
  4. Połączenia przewodowe: Connect the conductors to the appropriate terminal screws. The clear housing allows for visual verification of proper wire insertion. Ensure all connections are tight and secure.
  5. Assemble the Plug: Reassemble the plug housing, ensuring the internal components are correctly aligned. Tighten the compression nut to create a watertight seal and engage the strain relief system.
  6. Zweryfikować: Double-check all connections and ensure the plug is securely assembled before restoring power.

6. Działanie

The Leviton Wetguard Locking Plug is designed for secure and reliable electrical connections in wet or dusty environments. To operate:

  1. Łączyć: Align the blades of the locking plug with the corresponding slots on a compatible locking receptacle.
  2. Przekręć, aby zablokować: Insert the plug fully and twist it clockwise until it locks into place. This action creates a secure mechanical and electrical connection, preventing accidental disconnection.
  3. Odłączyć: To disconnect, twist the plug counter-clockwise to unlock, then pull it straight out from the receptacle.

The watertight design ensures safe operation even when exposed to moisture, provided the connection is properly mated and sealed.

7. Konserwacja

Regular maintenance helps ensure the longevity and safe operation of your Leviton Wetguard Locking Plug.

  • Przeglądy okresowe: Visually inspect the plug and cable for any signs of wear, cuts, cracks, or discoloration. Check for loose connections or corrosion on the blades.
  • Czyszczenie: Clean the exterior of the plug with a damp cloth. Avoid using harsh chemicals or abrasive cleaners that could damage the rubber material. Ensure the plug is dry before use.
  • Składowanie: When not in use, store the plug in a clean, dry environment to prevent damage and prolong its lifespan.
  • Integralność uszczelnienia: Periodically check the integrity of the compression nut and strain relief system to ensure the watertight seal is maintained.

8. Rozwiązywanie Problemów

If you encounter issues with your Leviton Wetguard Locking Plug, consider the following common troubleshooting steps:

  • Brak zasilania:
    • Check the power source (circuit breaker, fuse).
    • Ensure the plug is fully inserted and locked into the receptacle.
    • Sprawdź kabel pod kątem uszkodzeń.
  • Luźne połączenie:
    • Ensure the plug is twisted and locked securely.
    • If the internal wiring feels loose, disconnect power and re-check the terminal screw connections as per installation instructions.
  • Wnikanie wody:
    • Verify that the compression nut is tightly secured.
    • Inspect the rubber housing for any cracks or damage that could compromise the seal.

If the problem persists after attempting these steps, contact Leviton customer support or a qualified electrician.

9. Related Product Information (Video)

Poniższy film przedstawia więcejview of the Leviton Wetguard line of watertight wiring devices, showcasing their features and applications in various industrial environments. While the video may feature different models within the Wetguard series, the core principles of durability, watertight sealing, and robust construction apply to the 24W49 locking plug.

Wideo: Ponadview of Leviton Wetguard Watertight Wiring Devices

10. Gwarancja i wsparcie

The Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug (Model 24W49) is backed by a manufacturer's warranty. For specific warranty details, terms, and conditions, please refer to the product packaging or visit the official Leviton webstrona.

For technical assistance, product inquiries, or support, please contact Leviton Customer Service:

  • Webstrona: www.leviton.com
  • Obsługa klienta: Odnieś się do webstrona zawierająca regionalne informacje kontaktowe.

Powiązane dokumenty - 24W49

Przedview Przewodnik po wyborze przełączników klasy komercyjnej i przemysłowej Leviton
Kompleksowy przewodnik firmy Leviton, w którym szczegółowo opisano przełączniki klasy komercyjnej i przemysłowej, w tym przełączniki dźwigniowe, Decora Plus, Lev-lok, antybakteryjne i specjalistyczne, wraz ze szczegółami zastosowań i schematami okablowania.
Przedview Instrukcja instalacji i testowania gniazdka Leviton GFCI
Kompleksowy przewodnik na temat instalacji i testowania gniazdka GFCI Leviton SmartLock Pro, obejmujący instrukcje dotyczące okablowania, środki ostrożności i wskazówki dotyczące rozwiązywania problemów.
Przedview Leviton EV40P Seria EV 40 AMP Instrukcja instalacji ładowarki wtykowej
Instrukcja instalacji Leviton EV40P EV Series 40 AMP Ładowarka sieciowa do pojazdów elektrycznych. Zawiera ostrzeżenia dotyczące bezpieczeństwa, specyfikacje, kroki instalacji, procedury obsługi, informacje o użyciu karty RFID, komunikaty o błędach, konserwację i gwarancję.
Przedview Instrukcja instalacji i obsługi gniazda Leviton GFCI z portami USB
Kompleksowy przewodnik dotyczący instalacji i obsługi gniazdek Leviton GFCI z portami USB, obejmujący instrukcje dotyczące okablowania, ostrzeżenia dotyczące bezpieczeństwa, procedury testowe i informacje gwarancyjne.
Przedview Instalacja i testowanie inteligentnego gniazdka GFCI Leviton: kompleksowy przewodnik
Instrukcja krok po kroku dotycząca instalacji i testowania gniazd Leviton Smart GFCI (modele D2GF1, D2GF2). Dowiedz się więcej o działaniu GFCI, okablowaniu, rozwiązywaniu problemów i środkach ostrożności.
Przedview Instrukcja montażu obudowy centrum załadunku Leviton
Szczegółowa instrukcja montażu obudów rozdzielnic Leviton Load Center, modele LP2xx, LP3xx, LP4xx i LP6xx. Obejmuje ona kwestie bezpieczeństwa, wyłamywanie wyłamywanych otworów, montaż, okablowanie, instalację wyłącznika obwodu odgałęzionego oraz montaż pokrywy.