1. Wprowadzenie
This instruction manual provides essential information for the safe and effective use of the Leviton 23R23-E Single Pole 30 Degree Cam-Type Taper Nose Male Panel Receptacle. Please read this manual thoroughly before installation, operation, or maintenance to ensure proper function and to prevent potential hazards.
The Leviton 23R23-E is a heavy-duty, completely insulated electrical connector designed for robust power distribution systems, commonly used in applications requiring reliable, high-current connections such as those found in Navy bases and shipyards for supplying 3-phase power.
2. Informacje dotyczące bezpieczeństwa
WARNING: Risk of Electric Shock or Fire. Improper installation or use can lead to serious injury or death.
- Always disconnect power at the circuit breaker or fuse box before installing, servicing, or removing this device.
- Instalację powinien wykonać wykwalifikowany elektryk, zgodnie ze wszystkimi krajowymi i lokalnymi przepisami elektrycznymi.
- Nie używaj tego urządzenia, jeśli wygląda na uszkodzone.
- Sprawdź, czy wszystkie połączenia są solidne i właściwie zaizolowane.
- Ten produkt może zawierać substancje chemiczne, o których stan Kalifornia wie, że powodują raka, wady wrodzone lub inne uszkodzenia układu rozrodczego (ostrzeżenie zgodnie z Propozycją 65). Umyć ręce po kontakcie z produktem.
3. Koniec produktuview
The Leviton 23R23-E is a male panel receptacle designed for high-current electrical connections. It features a 30-degree cam-type taper nose and a threaded stud for secure mounting and connection.
Główne cechy:
- Shatter and Crack Proof Neoprene Rubber construction for durability.
- Waterproof when vulcanized, ensuring reliability in demanding environments.
- Tested by ETL Laboratories to meet Naval Specifications, ensuring high performance and safety standards.
- Designed for 250-750MCM wire sizes and a maximum of 690 Amps.
- Positive latching mechanism provides vibration resistance, preventing loosening and ensuring high conductivity.
- Male contacts offer enhanced surface contact for greater conductivity and reduced burnout risk.
Obraz produktu:

Image: The Leviton 23R23-E Single Pole Cam-Type Male Panel Receptacle, showing its black neoprene rubber body and threaded stud connection point.
Dane techniczne:
| Atrybut | Szczegół |
|---|---|
| Producent | Lewiton |
| Numer części | 23R23-E |
| Numer modelu przedmiotu | 23R23-E |
| Waga przedmiotu | 3.4 funta |
| Wymiary opakowania | 10.9 x 7 x 4.6 cala |
| Kolor | Heban |
| Tworzywo | Neoprene, Rubber |
| Ilość w opakowaniu przedmiotu | 1 |
| Orzecznictwo | ETL |
| Wire Size Compatibility | 250-750MCM |
| Maksymalny Ampwymazać | 690 Amp |
4. Konfiguracja i instalacja
IMPORTANT: Installation must be performed by a qualified electrician and comply with all applicable electrical codes and safety standards.
- Odłączenie zasilania: Ensure all power to the installation area is completely disconnected at the main circuit breaker or fuse panel before beginning any work. Verify with a voltagtester.
- Montowanie: The 23R23-E is a panel receptacle with a threaded stud. Securely mount the receptacle to the designated panel or enclosure using appropriate hardware for the threaded stud. Ensure a stable and rigid mounting surface.
- Przygotowanie drutu: Prepare the conductor cable (250-750MCM) according to standard electrical practices. Strip the insulation to the length specified by the connector's internal terminal.
- Podłączenie przewodu: Connect the prepared conductor to the receptacle's terminal. Ensure a tight and secure connection to prevent arcing or overheating. Follow manufacturer's torque specifications if provided.
- Izolacja: Verify that all exposed conductors are properly insulated and that no bare wires are accessible.
- Kontrola końcowa: Before restoring power, double-check all connections for tightness and proper insulation. Ensure the receptacle is firmly mounted.
- Przywróć zasilanie: Po zakończeniu instalacji i jej sprawdzeniu należy przywrócić zasilanie obwodu.
5. Instrukcja obsługi
The Leviton 23R23-E Cam-Type Receptacle is designed for simple and secure connection with compatible cam-type plugs.
- Connecting a Plug: Align the cam-type plug with the receptacle. Insert the plug into the receptacle and rotate it clockwise until it locks into place with a positive latching action. This ensures a secure, vibration-resistant connection.
- Disconnecting a Plug: To disconnect, rotate the cam-type plug counter-clockwise to disengage the latching mechanism, then pull the plug straight out from the receptacle.
Note: Always ensure the power source is de-energized before connecting or disconnecting high-current electrical devices, unless specifically designed for hot-swapping under controlled conditions.
6. Konserwacja
Regular inspection and maintenance will help ensure the longevity and safe operation of your Leviton 23R23-E receptacle.
- Kontrola wizualna: Periodically inspect the receptacle for any signs of physical damage, such as cracks, discoloration, or wear on the neoprene rubber body. Check for loose connections or corrosion on the threaded stud.
- Czyszczenie: If necessary, clean the exterior of the receptacle with a dry, lint-free cloth. For stubborn dirt, a mild, non-abrasive cleaner can be used, ensuring the device is completely dry before re-energizing. Do not use harsh chemicals or solvents.
- Integralność połączenia: Ensure that the threaded stud connection remains tight and secure. Over time, vibrations can cause connections to loosen.
- Kontrola profesjonalna: For critical applications, consider having a qualified electrician perform periodic checks of the entire power distribution system, including these receptacles.
7. Rozwiązywanie Problemów
If you experience issues with your Leviton 23R23-E receptacle, consider the following common troubleshooting steps. For complex electrical problems, always consult a qualified electrician.
- Brak zasilania:
- Sprawdź wyłącznik obwodu lub bezpiecznik obwodu.
- Verify that the cam-type plug is fully inserted and latched into the receptacle.
- Inspect the wiring connections at the receptacle for looseness or damage (with power off).
- Przegrzanie:
- Ensure the connected load does not exceed the receptacle's 690 Amp maksymalna ocena.
- Check for loose or corroded connections, which can cause resistance and heat buildup.
- Verify that the correct wire gauge (250-750MCM) is used and properly terminated.
- Trudności z podłączaniem/odłączaniem:
- Ensure the plug and receptacle are clean and free of debris.
- Check for any physical damage or deformation to the cam-type mechanism on either the plug or receptacle.
8. Informacje o gwarancji
The Leviton 23R23-E Single Pole Cam-Type Panel Receptacle comes with a 1 rok ograniczonej gwarancji from the date of purchase. This warranty covers defects in materials and workmanship under normal use. For specific terms and conditions, or to make a warranty claim, please refer to the official Leviton warranty documentation or contact Leviton customer support.
9. Wsparcie i kontakt
For further assistance, technical support, or inquiries regarding the Leviton 23R23-E, please contact Leviton customer service or visit their official webstrona.
- Leviton Official Webstrona: www.leviton.com
- Odnieś się do webstrona z numerami kontaktowymi i zasobami pomocy technicznej właściwymi dla Twojego regionu.