Technoline WS 6810 amber

Instrukcja obsługi stacji pogodowej Technoline WS 6810

Model: WS 6810 amber

1. Koniec produktuview

The Technoline WS 6810 amber Weather Station is a sophisticated device designed to provide accurate indoor and outdoor temperature readings, precise timekeeping via DCF-77 radio control, and convenient alarm functions. Its modern design with a warm amber LED display and black high-gloss finish integrates seamlessly into any contemporary home environment. This manual provides detailed instructions for setting up, operating, and maintaining your weather station.

Technoline WS 6810 Weather Station front view with amber LED display showing time and temperatures

Rycina 1.1: Przód view of the Technoline WS 6810 Weather Station, displaying indoor and outdoor temperatures, current time, and alarm indicators.

2. Zawartość opakowania

Please check the package contents carefully. If any items are missing or damaged, contact your retailer immediately.

Notatka: 3 x AAA Micro LR03 batteries for main unit backup and 2 x AAA Micro LR03 batteries for the outdoor sensor are nie wliczone i należy go zakupić osobno.

Technoline WS 6810 Weather Station main unit and TX96 outdoor sensor

Figure 2.1: The Technoline WS 6810 main unit alongside its TX96 outdoor sensor.

3. Główne cechy

4. Przewodnik konfiguracji

4.1. Włączanie jednostki głównej

  1. Connect the provided power supply unit to the DC IN port on the back of the WS 6810 main unit.
  2. Plug the power adapter into a standard 220V electrical outlet. The display will illuminate.
  3. Do zasilania awaryjnego podczastages, insert 3 x AAA Micro LR03 batteries (not included) into the battery compartment on the back of the main unit, observing polarity (+/-).

4.2. Installing Batteries in the Outdoor Sensor (TX96)

  1. Open the battery compartment on the back of the TX96 outdoor sensor.
  2. Insert 2 x AAA Micro LR03 batteries (not included), ensuring correct polarity.
  3. Dokładnie zamknij komorę baterii.

4.3. Initial Synchronization and Sensor Placement

  1. Place the outdoor sensor within effective transmission range (typically up to 30 meters in open air) of the main unit. Avoid placing it near large metal objects, electrical appliances, or direct sunlight.
  2. The main unit will automatically attempt to receive the DCF-77 radio signal for time synchronization and connect with the outdoor sensor. This process may take several minutes. A signal icon will appear on the display once synchronization is successful.
  3. If the outdoor temperature does not appear after a few minutes, press the "SENSOR" button on the main unit to manually initiate a search for the outdoor sensor.

4.4. Time Zone Setting (if required)

If you are in a region where the DCF-77 signal's standard time differs from your local time (e.g., outside Central European Time), you may need to adjust the time zone.

  1. In normal time display mode, press and hold the "SET" button until the time zone offset flashes.
  2. Use the "+" or "-" buttons to adjust the time zone offset in ±1 hour increments.
  3. Press "SET" again to confirm and exit.
Strona view of Technoline WS 6810 Weather Station showing control buttons on top

Rysunek 4.1: Góra view of the WS 6810, highlighting the control buttons for setup and operation.

5. Instrukcja obsługi

5.1. Wyświetlanie informacji

The large LED display shows the following information:

5.2. Ustawianie alarmów

The WS 6810 features two independent alarms (ALM1 and ALM2).

  1. Press the "ALARM" button repeatedly to cycle through ALM1, ALM2, and normal time display.
  2. When ALM1 or ALM2 is displayed, press and hold the "ALARM" button until the alarm time flashes.
  3. Use the "+" or "-" buttons to adjust the hour, then press "ALARM" to confirm and move to minutes.
  4. Use the "+" or "-" buttons to adjust the minutes, then press "ALARM" to confirm.
  5. To activate/deactivate an alarm, select ALM1 or ALM2 display, then press the "+" button. An alarm icon will appear/disappear.

5.3. Funkcja drzemki

When an alarm sounds, press the "SNOOZE/LIGHT" button to activate the snooze function. The alarm will temporarily stop and sound again after approximately 5 minutes.

5.4. Regulacja jasności wyświetlacza

Press the "SNOOZE/LIGHT" button (when no alarm is sounding) to toggle between the two available brightness levels for the LED display.

5.5. Viewing Min/Max Temperatures

Press the "MIN/MAX" button to cycle through the current, maximum, and minimum recorded indoor and outdoor temperatures. To reset the min/max records, press and hold the "MIN/MAX" button while the min/max values are displayed.

6. Konserwacja

7. Rozwiązywanie Problemów

ProblemMożliwa przyczynaRozwiązanie
Brak obrazu na jednostce głównej.Power adapter not connected or faulty; batteries (backup) are dead or incorrectly inserted.Ensure power adapter is securely plugged in. Check and replace backup batteries, ensuring correct polarity.
Outdoor temperature not displayed or inaccurate.Baterie czujnika zewnętrznego są rozładowane; czujnik jest poza zasięgiem; występują zakłócenia; czujnik nie jest sparowany.Replace outdoor sensor batteries. Move sensor closer to the main unit. Avoid placing near electronics. Press "SENSOR" button on main unit to re-establish connection.
Czas jest nieprawidłowy lub nie jest zsynchronizowany.Weak DCF-77 signal; interference; incorrect time zone setting.Relocate the main unit to an area with better signal reception (e.g., near a window, away from electronics). Check time zone setting. Manual time setting is available if radio control fails.
Alarm nie działa.Alarm is not activated; alarm volume too low (not applicable for this model, but common issue).Ensure the alarm icon (ALM1 or ALM2) is displayed, indicating activation. Re-set the alarm time.

8. Specyfikacje techniczne

ModelWS 6810 amber
Wymiary jednostki głównej (dł. x szer. x wys.)28.5 x 7 x 5.5 cm (ok. 11.2 x 2.8 x 2.2 cala)
Waga jednostki głównej500 g (ok. 1.1 funta)
Outdoor Sensor (TX96) Dimensions (L x W x H)50 x 22 x 104 mm (około 2.0 x 0.9 x 4.1 cala)
Zasilacz (jednostka główna)220V AC Power Adapter (included)
Backup Power (Main Unit)3 x AAA Micro LR03 batteries (not included)
Zasilacz (czujnik zewnętrzny)2 x AAA Micro LR03 batteries (not included)
Typ wyświetlaczaDioda LED (bursztynowa)
Synchronizacja czasuDCF-77 Radio Controlled
Zakres temperatur (wewnątrz)(Information not provided, typical range is 0°C to 50°C)
Zakres temperatur (na zewnątrz)(Information not provided, typical range is -20°C to 60°C)

9. Gwarancja i wsparcie

Technoline products are manufactured to high quality standards. For warranty information, technical support, or service inquiries, please contact your retailer or visit the official Technoline webstrona.

Oficjalna strona produktu: http://www.technoline.eu/products/en/4029665068107

Proszę zachować dowód zakupu na potrzeby roszczeń gwarancyjnych.

Powiązane dokumenty - WS 6810 amber

Przedview Instrukcja obsługi zegara i stacji pogodowej sterowanej radiowo WS8014
Instrukcja obsługi radiowo sterowanego zegara i stacji pogodowej WS8014, obejmująca informacje na temat funkcji, konfiguracji, obsługi, specyfikacji i bezpieczeństwa.
Przedview Instrukcja obsługi bezprzewodowej stacji pogodowej 868 MHz
Comprehensive instruction manual for the Wireless 868 MHz Weather Station, covering features, setup, operation, weather forecasting, and specifications. Includes details on indoor and outdoor temperature monitoring, DCF-77 radio-controlled time, and alarm functions.
Przedview Weather Forecast Memo Alarm Clock Instructions Manual - TechnoLine
Comprehensive instruction manual for the TechnoLine Weather Forecast Memo Alarm Clock, detailing setup, features, radio-controlled time, weather forecasting, alarm functions, and specifications.
Przedview Memo Alarm Clock Operating Manual: Radio Controlled Time and Features
Comprehensive operating manual for the Memo Alarm Clock, detailing features, setup, radio-controlled time reception, manual time setting, alarm functions, maintenance, and specifications.
Przedview Funkwecker mit Projektion WT519 User Manual
User manual for the Technoline WT519 projection alarm clock, covering setup, function keys, display modes, time and alarm settings, and important usage notes.
Przedview Stacja pogodowa TechnoLine WS6620: Instrukcja obsługi i przewodnik konfiguracji
Detailed instruction manual for the TechnoLine WS6620 Desktop Weather Station. Learn how to set up, operate, and interpret weather forecasts, temperature, humidity, and barometric pressure readings. Includes guidance on remote sensor installation, RCC time synchronization, and alarm settings.