This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of the Sealey RE232 Coil Spring Compressing Station. This unit is an air-actuated hydraulic tool designed for compressing coil springs with a capacity of up to 1500kg. It offers a quicker and easier alternative to traditional ratchet-driven spring compressors.
Please read this manual thoroughly before operating the equipment to ensure proper use and to prevent injury or damage.
2. Informacje dotyczące bezpieczeństwa
OSTRZEŻENIE: Nieprzestrzeganie tych instrukcji może spowodować poważne obrażenia lub śmierć.
- Zawsze należy nosić odpowiedni sprzęt ochrony osobistej (PPE), obejmujący okulary ochronne, rękawice i solidne obuwie.
- Ensure the unit is placed on a stable, level, and non-slip surface before operation.
- Nie przekraczaj maksymalnego obciążenia wynoszącego 1500 kg.
- Ensure the air supply pressure does not exceed 120psi (8.3 bar).
- Keep hands and other body parts clear of moving parts during operation.
- Inspect the unit for damage or wear before each use. Do not operate if damaged.
- Only use the unit for its intended purpose: compressing coil springs within the specified diameter range (Ø80mm to Ø175mm).
- Ensure the spring is securely seated in the plastic-coated yokes before applying pressure.
- Nie modyfikuj w żaden sposób sprzętu.
- Trzymaj dzieci i osoby nieupoważnione z dala od miejsca pracy.
3. Komponenty i części
The Sealey RE232 Coil Spring Compressing Station consists of the following main components:
- Main Vertical Column with adjustable upper yoke positions.
- Hydraulic Cylinder and Piston Assembly.
- Air Actuated Control Valve.
- Foot Pedal for alternative operation.
- Upper and Lower Plastic-Coated Yokes (suitable for springs Ø80mm to Ø175mm).
- Base Plate for stability.
- Air Hose with quick connector.


4. Konfiguracja
- Rozpakowywanie: Carefully remove all components from the packaging. Inspect for any shipping damage. Report any damage to your supplier immediately.
- Montaż: The main unit typically comes pre-assembled. Ensure all bolts and fasteners are tight before first use. Refer to the assembly diagram (if provided separately) for detailed steps if any assembly is required.
- Umieszczenie: Position the compressing station on a firm, level, and clean concrete surface capable of supporting the unit's weight and the maximum load. Ensure adequate clear space around the unit for safe operation.
- Podłączenie zasilania powietrzem: Connect a suitable air compressor to the air inlet on the unit using the provided air hose. Ensure the air supply is clean, dry, and regulated to a maximum of 120psi (8.3 bar).
- Kontrola wstępna: Before loading a spring, perform a test cycle by operating the foot pedal or air control to ensure the hydraulic ram extends and retracts smoothly.
5. Instrukcja obsługi
- Prepare the Spring: Ensure the coil spring is clean and free from debris.
- Position the Yokes: Adjust the upper yoke to an appropriate height for the spring being compressed. The unit features 7 upper yoke positions for versatility. The lower yoke has a travel of 340mm.
- Load the Spring: Carefully place the coil spring into the plastic-coated yokes. Ensure it is centered and securely seated. The yokes are designed for springs with diameters from Ø80mm to Ø175mm.
- Compress the Spring:
- Air Actuation: Use the air control valve to slowly apply pressure, causing the hydraulic ram to compress the spring.
- Działanie pedału nożnego: Alternatively, use the foot pedal to manually actuate the hydraulic unit and compress the spring.
- Secure the Spring: Once the spring is compressed to the desired level, secure it using appropriate spring clamps or retaining tools (not included with the unit).
- Ciśnienie zwolnienia: Slowly release the pressure from the hydraulic unit.
- Remove the Spring: Carefully remove the secured spring from the compressing station.
Notatka: The plastic-coated yokes are designed to reduce the risk of spring slippage or damage during the compression process.
6. Konserwacja
Regular maintenance ensures the longevity and safe operation of your Sealey RE232 Coil Spring Compressing Station.
- Codzienna kontrola: Before each use, inspect the unit for any visible damage, loose fasteners, or signs of hydraulic fluid leaks. Check the condition of the air hose and connections.
- Czyszczenie: Keep the unit clean and free from dirt, grease, and debris. Wipe down surfaces with a clean cloth. Do not use harsh solvents that could damage paint or seals.
- Poziom płynu hydraulicznego: Periodically check the hydraulic fluid level. Refer to the unit's specific instructions for accessing the reservoir and the type of hydraulic fluid recommended (typically ISO VG 32 or equivalent). Top up if necessary.
- Smarowanie: Lubricate moving parts and pivot points as recommended by the manufacturer to ensure smooth operation.
- Składowanie: When not in use, store the unit in a clean, dry, and secure location, away from extreme temperatures and corrosive environments.
- Serwis profesjonalny: Any repairs or major maintenance, especially involving the hydraulic system, should only be performed by qualified personnel.
7. Rozwiązywanie Problemów
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Unit does not compress spring or compresses slowly. | Low air pressure; Insufficient hydraulic fluid; Air in hydraulic system; Leaking seals. | Check air supply and pressure (max 120psi); Check and top up hydraulic fluid; Bleed air from system (refer to service manual); Contact qualified service personnel for seal replacement. |
| Hydraulic ram does not retract fully. | Return spring issue; Obstruction; Air in system. | Check for obstructions; Bleed air from system; Contact qualified service personnel. |
| Nietypowe dźwięki podczas pracy. | Lack of lubrication; Loose components; Internal hydraulic issue. | Lubricate moving parts; Check and tighten all fasteners; Cease operation and contact qualified service personnel. |
| Spring slips from yokes. | Improper seating of spring; Spring diameter outside specified range; Damaged yokes. | Ensure spring is correctly centered and seated; Verify spring diameter is between Ø80mm and Ø175mm; Inspect and replace damaged yokes. |
8. Specyfikacje
| Specyfikacja | Wartość |
|---|---|
| Numer modelu | RE232 |
| Maksymalna ładowność | 1500kg |
| Upper Yoke Positions | 7 |
| Lower Yoke Travel | 340mm |
| Spring Diameter Range | Ø80mm - Ø175mm |
| Aktywacja | Air or Foot Pedal |
| Maksymalne ciśnienie powietrza | 120 8.3 psi (XNUMX barów) |
| Wymiary produktu (dł. x szer. x wys.) | 33 x 123 x 7 cm (w przybliżeniu, na podstawie danych produktu) |
| Waga przedmiotu | 37 kilogramów |
| Kolor | Czerwony |
9. Gwarancja i wsparcie
For warranty information, technical support, or to purchase replacement parts, please contact Sealey customer service or visit the official Sealey webZachowaj dowód zakupu na wypadek roszczeń gwarancyjnych.
Sealey Contact Information:
- Webstrona: www.sealey.pl