Produkt ponadview
The Fluke 115 Field Service True-RMS Technicians Multimeter is a compact and versatile instrument designed for a wide variety of electrical and electronic testing applications. It provides accurate True-RMS voltage and current readings, along with capabilities for testing resistance, continuity, frequency, and capacitance. Its robust design and clear display make it suitable for field technicians and professionals requiring reliable measurements.

Rycina 1: Przód view of the Fluke 115 Digital Multimeter, showing the display, rotary dial, and input jacks.
Co jest w pudełku
- Fluke 115 Multimeter
- Kabura
- 9V Battery (installed)
- 4mm Silicone Test Lead Set
- Instrukcja obsługi

Figure 2: Contents of the Fluke 115 package, including the multimeter, test leads, and user manual.
Organizować coś
1. Montaż baterii (jeśli nie została zainstalowana fabrycznie)
The Fluke 115 typically comes with the 9V battery pre-installed. If replacement is needed, locate the battery access door on the back of the unit. Use a screwdriver to open the compartment, insert a new 9V battery, ensuring correct polarity, and secure the door.
2. Podłączanie przewodów pomiarowych
- Włóż czarny przewód pomiarowy do KOM (wspólne) gniazdo wejściowe.
- Włóż czerwony przewód pomiarowy do odpowiedniego gniazda wejściowego, zależnie od rodzaju pomiaru:
- Dla voltage (V), resistance (Ω), capacitance, and frequency (Hz) measurements, use the VΩ Hz gniazdo wejściowe.
- For current (A) measurements up to 10A, use the 10 A BEZPIECZNIK gniazdo wejściowe.

Figure 3: The Fluke 115 Multimeter being held, demonstrating its compact size and ease of handling for field use.
Instrukcja obsługi
The Fluke 115 features a large rotary dial for selecting measurement functions and buttons for additional features like HOLD, MIN/MAX, and RANGE.
Funkcje pomiarowe
- AC/DC Objętośćtage (V∼ / V—): Select the V∼ (AC) or V— (DC) position on the rotary dial. The meter measures True-RMS voltage do 600V.
- Rezystancja (Ω): Select the Ω position. The meter will display resistance in Ohms.
- Ciągłość (♫): Select the continuity position. A simple beep indicates when a wire or fuse is functioning properly.
- Pojemność (⊥): Select the capacitance position. Measures capacitance values.
- Częstotliwość (Hz): Select the Hz position. Measures the frequency of AC signals.
- AC/DC Current (A∼ / A—): Select the A∼ (AC) or A— (DC) position. Measures current up to 10A (20A momentary for 30 seconds).
- Test diody (→|—): Select the diode test position to check diode functionality.
Cechy specjalne
- Min/Max/Average: Naciśnij MINMAX button to record signal fluctuations over time. This feature captures the minimum, maximum, and average readings.
- Trzymać: Naciśnij TRZYMAĆ przycisk, aby zamrozić aktualny odczyt na wyświetlaczu.
- Zakres: The meter features auto-ranging. Press the RANGE button to manually select a measurement range if desired.
- Podświetlenie: Press the backlight button (sun icon) to illuminate the display for work in poorly lit areas.

Figure 4: The Fluke 115 Multimeter being used to take measurements on an electrical panel, highlighting its practical application.
Konserwacja
Wymiana baterii i bezpiecznika
To replace the battery or fuses, refer to the detailed instructions in the full user manual. The meter's yellow protective holster can be removed to access the battery and fuse compartment on the back. Ensure the meter is turned off and test leads are disconnected before attempting any maintenance.

Figure 5: The Fluke 115 Multimeter positioned on a workbench, ready for use or maintenance.
Rozwiązywanie problemów
Typowe problemy i rozwiązania
- No Display or Faint Display: Check battery level and replace if necessary. Ensure the battery contacts are clean. If the display remains faint, refer to the full user manual for advanced troubleshooting steps, which may involve cleaning internal display connections.
- Niedokładne odczyty: Verify that the test leads are properly connected to the correct input jacks for the selected measurement function. Ensure the rotary dial is set to the appropriate function. Check for damaged test leads or probes.
- Meter Does Not Turn On: Confirm the battery is correctly installed and has sufficient charge.
Specyfikacje
| Funkcja | Szczegół |
|---|---|
| Marka | Fuks |
| Numer modelu | 115 |
| Wymiary produktu | 10.83 x 16 x 3.94 cala; 1.32 funta |
| Waga przedmiotu | 600 gram |
| Źródło zasilania | Zasilany bateryjnie (wymagane 2 baterie AA, dołączone) |
| Styl | MULTIMETR PRAWDZIWEJ RMS |
| Kolor | Żółty |
| Ocena bezpieczeństwa | CAT III 600 V. |
| Tomtage Pomiar | AC/DC Objętośćtage do 600 V |
| Pomiar prądu | Current up to 10 A (20 A momentary for 30 seconds) |
| Inne pomiary | Resistance, Continuity, Frequency, Capacitance |
| Wyświetlacz | 6000 count resolution with large white LED backlight |
Informacje o gwarancji
Specific warranty details for the Fluke 115 Digital Multimeter are typically provided by the manufacturer, Fluke, at the time of purchase or within the official product documentation. Please refer to the warranty card included with your product or visit the official Fluke website for the most current and comprehensive warranty terms and conditions.
Note: The provided product information includes a legal disclaimer regarding returns: "Returns accepted on all unopened merchandise. 10% restocking fee applies." This pertains to return policy and not the product's operational warranty.
Wsparcie
For technical assistance, product inquiries, or service, please contact Fluke customer support directly. You can find contact information and additional resources on the official Fluke webstrona.