AGS BL520

Instrukcja obsługi przewodów hamulcowych AGS BL520

Model: BL520

Wstęp

This manual provides essential information for the proper installation, operation, and maintenance of your AGS BL520 Brake Line. The AGS BL520 is a high-quality steel brake line designed for automotive braking systems. Please read this manual thoroughly before installation to ensure safety and optimal performance.

Produkt ponadview

The AGS BL520 is a durable steel brake line, measuring 20 inches in length, designed to withstand the pressures and conditions of an automotive braking system. It features standard fittings for secure connections.

AGS BL520 Brake Line with fittings

Obraz: Zbliżenie view of the AGS BL520 steel brake line, showing the main steel tubing and the two threaded brass-colored fittings at each end. The line appears straight and rigid.

Główne cechy:

Specyfikacje

AtrybutSzczegół
MarkaAGS
Numer modeluBL520
TworzywoStal stopowa
KolorStal
Wymiary produktu (dł. x szer.)20" dł. x 0.5" szer. (50.8 cm x 1.27 cm)
Nominalna grubość ścianki1.3 mm
Waga przedmiotu2.4 uncji (0.068 kg)
UPC077146359163

Wytyczne dotyczące instalacji

Installation of brake lines should only be performed by qualified personnel with appropriate tools and safety equipment. Improper installation can lead to brake system failure and serious injury.

Wymagane narzędzia i materiały:

Kroki instalacji:

  1. Bezpieczeństwo przede wszystkim: Ensure the vehicle is securely lifted and supported on jack stands. Disconnect the negative terminal of the battery.
  2. Spuść płyn hamulcowy: Place a drain pan under the master cylinder or the lowest point of the brake system. Open the bleeder valves to drain the old brake fluid.
  3. Usuń starą linię: Carefully loosen and remove the fittings connecting the old brake line. Be prepared for residual brake fluid to leak.
  4. Sprawdź połączenia: Before installing the new line, inspect the mating surfaces for corrosion or damage. Clean as necessary.
  5. Install New Line: Route the new AGS BL520 brake line exactly as the original. Ensure there are no kinks or sharp bends. Hand-tighten the fittings first to avoid cross-threading.
  6. Dokręcić złączki: Using a flare nut wrench, tighten the fittings to the manufacturer's specified torque. Nie dokręcaj zbyt mocno.
  7. Refill and Bleed: Refill the master cylinder with new, clean brake fluid. Bleed the entire brake system according to your vehicle's service manual to remove all air.
  8. Sprawdź, czy nie ma wycieków: After bleeding, apply firm pressure to the brake pedal and check all new connections for leaks. Repeat this process several times.
  9. Jazda próbna: Perform a low-speed test drive in a safe area to confirm proper brake function before normal operation.

Działanie

The AGS BL520 Brake Line is a passive component within your vehicle's hydraulic braking system. Its primary function is to safely transfer hydraulic pressure from the master cylinder to the brake calipers or wheel cylinders, enabling the vehicle to slow down or stop. Once properly installed and the brake system is bled, the brake line operates continuously as part of the braking circuit.

Proper operation relies on a sealed system free from leaks and air. Any compromise to the integrity of the brake line or its connections will directly impact braking performance.

Konserwacja

Regular inspection and maintenance are crucial for the longevity and safety of your brake system, including the AGS BL520 Brake Line.

Rozwiązywanie problemów

If you experience issues with your braking system after installing or while using the AGS BL520 Brake Line, consider the following common problems and solutions:

Notatka: For any persistent or severe braking issues, consult a certified automotive technician immediately. Do not attempt to drive a vehicle with compromised brakes.

Informacje o gwarancji

For specific warranty terms and conditions regarding the AGS BL520 Brake Line, please refer to the official AGS manufacturer's warranty documentation provided with your purchase or visit the AGS official website. Warranty coverage typically addresses manufacturing defects and material flaws under normal use conditions.

Obsługa klienta

If you require further assistance, have questions about the AGS BL520 Brake Line, or need technical support, please contact AGS customer service through their official channels. You can typically find contact information on the manufacturer's webmiejscu lub na opakowaniu produktu.

For general inquiries or to find more products from AGS, you may visit the AGS Store on Amazon.

Powiązane dokumenty - BL520

Przedview Karta specyfikacji cyfrowego czujnika CO2, temperatury i wilgotności do montażu kanałowego AGS TP-DS-CO2RHT-BMS
Niniejszy dokument zawiera szczegółowe specyfikacje czujnika AGS TP-DS-CO2RHT-BMS, cyfrowego czujnika do montażu kanałowego do pomiaru CO2, temperatury i wilgotności. Czujnik ten charakteryzuje się technologią NDIR, jest kompatybilny z BACnet MS/TP i Modbus RTU oraz posiada automatyczną kalibrację do zastosowań HVAC.
Przedview Ogólna konfiguracja telefonu komórkowego Bluetooth dla sieci VRS z TSC2
Kompleksowy przewodnik szczegółowo opisujący kroki konfiguracji telefonów komórkowych z włączoną technologią Bluetooth do współpracy z sieciami VRS za pomocą urządzenia TSC2. Obejmuje wstępną konfigurację telefonu, parowanie Bluetooth, nawiązywanie połączenia sieciowego i testowanie połączenia internetowego.
Przedview Instrukcja montażu i obsługi czujnika czynnika chłodniczego VRF serii Merlin RG
Kompleksowa instrukcja instalacji i obsługi czujnika czynnika chłodniczego AGS Merlin serii RG VRF. Zawiera ważne informacje dotyczące bezpieczeństwa, procedury instalacji, okablowania, konfiguracji, obsługi, kalibracji i specyfikacji technicznych.
Przedview Detektor gazu Merlin iS: Instrukcja instalacji, obsługi i konserwacji opracowana przez American Gas Safety
W niniejszej instrukcji znajdują się szczegółowe instrukcje dotyczące detektora gazu American Gas Safety Merlin iS, obejmujące instalację, obsługę, konserwację, rozwiązywanie problemów oraz specyfikacje dotyczące wykrywania gazu chłodniczego.
Przedview AGS Mini Merlin CH4CO-35 Dual Gas Controller Installation and Operation Manual
Comprehensive installation, operation, and maintenance guide for the AGS Mini Merlin CH4CO-35 Dual Gas Controller, detailing safety, setup, wiring, operation, and maintenance procedures for detecting Methane (CH4) and Carbon Monoxide (CO).
Przedview Instrukcja montażu i obsługi czujnika czynnika chłodniczego VRF serii Merlin RG
Kompleksowy podręcznik instalacji i obsługi czujnika czynnika chłodniczego VRF serii AGS Merlin RG, obejmujący informacje na temat bezpieczeństwa, instalacji, obsługi, kalibracji i specyfikacji technicznych.