Wstęp
Welcome to the Aiphone LEF-5 Open Voice Selective Call Master Intercom user manual. This document provides detailed instructions for the proper installation, operation, and maintenance of your intercom system. Please read this manual thoroughly before using the product to ensure optimal performance and safety.
Co jest w pudełku?
- Aiphone LEF-5 Master Intercom Unit
- Sprzęt montażowy
- Instrukcja obsługi (ten dokument)
Produkt ponadview
The Aiphone LEF-5 is a master intercom unit designed for selective calling and communication within a building, capable of connecting with up to five other intercoms (door, sub-master, or master units). It features a door-release button for remote access control.

Obraz 1: Przód view of the Aiphone LEF-5 Master Intercom. The unit features a large speaker grille at the top. Below the speaker, there are five numbered call buttons (L1, L2, 3, 4, 5) with an 'OFF' indicator. A volume slider labeled 'VOL' is located on the left side of the control panel. An 'OCCUPIED' indicator is centrally located. On the right, there are three push buttons: 'LOCK' for door release, 'PRIV' for privacy, and 'TALK' for communication, with a 'CALL' indicator above the 'PRIV' button.
Organizować coś
Montowanie
The LEF-5 master intercom can be mounted on a desktop or wall. Use the provided mounting hardware to secure the unit in your desired location. Ensure the mounting surface is stable and allows for proper cable routing.
Połączenia okablowania
The LEF-5 requires hardwired connections to other intercom units and a power supply. Each intercom in the system must be connected to an Aiphone RY-PA relay (sold separately) to enable door access control (e.g., electric strike) and integration with other devices like CCTV cameras or lights.
- Połączenia interkomowe: Connect the LEF-5 to Aiphone LAF and LEF Series master intercoms or LA, LE, and LS Series door and sub-master intercoms. Refer to the wiring diagrams provided with your specific system components for correct connections.
- Door Strike Connection: An Aiphone RY-PA relay (sold separately) is required to connect an electric strike (sold separately) for remote door access control.
Zasilacz
The system is powered by a 12V power supply. An Aiphone PS-1225UL 12V power supply (sold separately) is recommended. Ensure the power supply is correctly connected according to the wiring instructions before operation.
Instrukcja obsługi
Wykonywanie połączenia
- Identify the desired intercom unit (door, sub-master, or master) you wish to call.
- Press the corresponding numbered button (L1, L2, 3, 4, or 5) on the LEF-5 unit. An LED indicator above the button will illuminate.
- Naciśnij i przytrzymaj ROZMAWIAĆ button to speak. Release the ROZMAWIAĆ przycisk, aby wysłuchać odpowiedzi.
Odbieranie połączenia
When a call is received from a sub-master intercom, a momentary chime will sound, and the corresponding LED indicator above the selectable call button will illuminate for approximately 20 seconds.
- To respond, press and hold the ROZMAWIAĆ przycisk.
- Uwolnij ROZMAWIAĆ button to listen to the other party.
Komunikacja dwukierunkowa
The LEF-5 operates on a push-to-talk, release-to-listen principle. Depressing the ROZMAWIAĆ button allows you to transmit audio, and releasing it allows you to receive audio from the connected intercom.
Door Release Function
To remotely unlock a door connected to the system (requires Aiphone RY-PA relay and electric strike), press the ZAMEK button during a conversation with the door intercom.
Funkcja prywatności
Naciśnij PRYWATNY (Privacy) button to prevent other intercom users within the system from overhearing your conversation with another intercom unit.
Listening Function
At any time, you can listen to audio transmissions from a specified door or sub-master intercom. Select the desired intercom using its numbered button, then activate the listening feature (specific activation method may vary, refer to system wiring for details).
Regulacja głośności
Adjust the audio volume using the TOM slider control located on the front panel.
Wyłączenie dzwonka
To silence the master intercom's chime alerts for incoming calls, slide the 'OFF' switch to the 'OFF' position.
Konserwacja
To ensure the longevity and proper functioning of your Aiphone LEF-5 intercom, follow these simple maintenance guidelines:
- Czyszczenie: Use a soft, dry cloth to clean the exterior of the unit. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish.
- Środowisko: Keep the unit in a dry environment, away from direct sunlight, extreme temperatures, and excessive dust.
- Inspekcje: Okresowo sprawdzaj wszystkie połączenia przewodów, aby mieć pewność, że są solidne i nieuszkodzone.
Rozwiązywanie problemów
If you encounter issues with your Aiphone LEF-5 intercom, refer to the following common problems and solutions:
- Brak zasilania:
Objaw: The unit does not power on, and no indicators light up.
Rozwiązanie: Verify that the 12V power supply is correctly connected and functioning. Check all power wiring for secure connections. - Brak dźwięku / słaba jakość dźwięku:
Objaw: Cannot hear or be heard, or audio is distorted.
Rozwiązanie: Sprawdź TOM slider to ensure it is not set to minimum. Inspect all communication wiring for proper connection and integrity. Ensure the correct intercom unit is selected. - Otwieranie drzwi nie działa:
Objaw: Naciśnięcie ZAMEK button does not unlock the door.
Rozwiązanie: Confirm that an Aiphone RY-PA relay and an electric strike are correctly installed and wired to the system. Check the wiring between the LEF-5, the RY-PA relay, and the electric strike. - Komunikacja przerywana:
Objaw: Communication cuts in and out.
Rozwiązanie: Inspect all wiring connections for looseness or damage. Ensure proper wire gauge is used for the distance (e.g., 22 AWG for up to 650 ft, 18 AWG for up to 1,600 ft). - Call LED Not Illuminating:
Objaw: No LED indication when a call is received or initiated.
Rozwiązanie: Check the connection to the calling intercom unit. Ensure the 'OFF' switch is not engaged if expecting a chime.
If these troubleshooting steps do not resolve the issue, please contact Aiphone customer support or a qualified technician.
Specyfikacje
| Numer modelu | LEF-5 |
| Wymiary całkowite (wys. x szer. x gł.) | 8-1/8 x 7-1/2 x 2-3/16 cala |
| Communication Output (Reception) | 800 mW przy 20 omach |
| Communication Output (Transmission) | 500 mW przy 20 omach |
| Maximum Distance (Door/Sub to Master) | 650 ft (using 22 AWG wire) 1,600 ft (using 18 AWG wire) |
| Door Strike Connection | Requires Aiphone RY-PA relay (sold separately) |
| Wymagania dotyczące zasilania | Aiphone PS-1225UL 12V power supply (sold separately) |
Gwarancja i wsparcie
For information regarding warranty coverage, technical support, or service, please refer to the official Aiphone website or contact Aiphone customer service directly. Keep your purchase receipt as proof of purchase for any warranty claims.
Aiphone North American Headquarters: Bellevue, WA