1. Wprowadzenie
The DeepVNA 101 HW V3.2 is a handheld vector network analyzer designed for HF/VHF/UHF antenna analysis. It is an upgraded version of the DEEPELEC NanoVNA-F HW3.1, featuring several enhancements for improved user experience and performance.
Key Features and Upgrades:
- Enkoder obrotowy: User buttons have been replaced with a rotary encoder for more convenient and smoother control.
- Zegar czasu rzeczywistego (RTC): New RTC circuit with real-time clock and perpetual calendar functions.
- Zoptymalizowana wydajność S21: Improved S21 insertion loss/filter measurement performance with a larger dynamic range.
- Firmware Version 1.0.4: Includes RTC, measurement data file naming (YYMMDD_HHMMSS), flexible frequency setting (start/end or center span mode), and boot sound control.
- Możliwości pomiarowe: Measures S-parameters, transmission test, reflection test, insertion loss, return loss, fault location (TDR function), antenna standing wave, impedance, and filter response.
2. Zawartość opakowania
The DeepVNA 101 package includes the following items:


Lista wysyłkowa:
- DeepVNA 101 4.3-inch screen unit x1 (includes free screen protector)
- Kabel USB-A do USB typu C x1
- 20CM kabel RF SMA męski do męskiego RG316 x2
- Element kalibracyjny męski SMA - OTWARTY x1
- Element kalibracyjny męski SMA - KRÓTKI x1
- Element kalibracyjny męski SMA - OBCIĄŻENIE x1 (w paśmie 4 GHz, SWR < 1.025)
- Złącze męskie-męskie SMA-JJ x1
- Złącze żeńskie-żeńskie SMA-KK x1
- Złącze męskie SMA-JKW męskie na żeńskie pod kątem prostym x1
- Składany stojak na maszynę x1
- Rezystancyjny rysik dotykowy x1
- Przewodnik szybkiego startu x1
- Darmowa torba ochronna EVA x1
3. Koniec produktuview
The DeepVNA 101 is available in two main casing options: an aluminum metal shell (aluminum alloy black oxide shell) and an ABS plastic shell. Both versions share identical internal parameters, performance, and accessories.



The device features a 4.3-inch IPS LCD screen. On the left side, you will find PORT 1 and PORT 2 connectors, labeled S11 and S21 respectively, for connecting to the device under test. The right side includes a rotary encoder for navigation and input, a 5V Out USB port, an ON/OFF switch, and a Type-C charging port.



4. Specyfikacje
| Sprzęt komputerowy | Przedmiot | 10 tys. ~ 300 MHz | 300 ~ 900MHz | 900M ~ 1.5 GHz |
|---|---|---|---|---|
| DeepVNA 101 V3.2 2022 new version Added rotary encoder and RTC functions. | S11 Zakres pomiarowy | > 70 dB | > 60 dB | > 50 dB |
| S21 Zakres pomiarowy | > 70 dB | > 60 dB | > 50 dB | |
| Wyjście PORT1 | Up to 0 dBm (3rd harmonic) | |||
| Wejście PORT2 | Measuring input < 0 dBm, tolerance power: +20 dBm | |||
Dane ogólne:
- Częstotliwość nominalna: 10 kHz - 1.5 GHz
- Punkty skanowania: Do 301 punktów
- Pojemność baterii: 5000 mAh / 3.7 V.
- Pojemność pamięci: 16MB (stores up to approximately 1000 sets of .snp file dane)
- Ekran: Tak
- Zasilanie: Akumulator do ładowania
- Styl: Przenośny
- Typ: AM / FM, FM, MW, SW, LW

5. Konfiguracja i pierwsze użycie
5.1 Włączanie/wyłączanie
To power on the DeepVNA 101, locate the ON/OFF switch on the right side of the device and slide it to the 'ON' position. The device will boot up and display the DEEPELEC logo and firmware information.

Aby wyłączyć urządzenie, przesuń przełącznik ON/OFF do pozycji „OFF”.
5.2 Ładowanie
Connect the provided USB Type-C cable to the 'Type-C Charging' port on the device and a suitable USB power source (e.g., computer USB port, USB wall adapter). The device uses a 5000mAh/3.7V rechargeable battery pack.
5.3 Connecting Antennas/Devices
Use the provided SMA cables and connectors to attach your antenna or device under test to PORT 1 (S11) or PORT 2 (S21) as required for your measurement. For SWR measurements, typically PORT 1 is used.

6. Działanie
6.1 Nawigacja i wprowadzanie danych
The DeepVNA 101 features a resistive touch screen and a rotary encoder for navigation. The rotary encoder provides convenient and smooth control for menu selection and value adjustment. The touch screen allows direct interaction with on-screen elements.
Specjalne przypomnienie: The resistive touch screen operates based on pressure sensing. Installing a screen protector may affect touch screen operation. It is recommended not to install one unless necessary.
6.2 Pomiary podstawowe
The device can perform various measurements, including S11 (reflection) and S21 (transmission).


6.3 Ustawianie częstotliwości
The frequency setting can be configured using either the start and end frequency mode or the center span mode. Use the touch screen or rotary encoder to input desired frequency values.
6.4 Regulacja jasności
The screen brightness can be adjusted via the menu. Navigate to the brightness setting and use the rotary encoder or touch input to change the level.

6.5 Saving Measurement Data
Measurement data can be saved to the internal 16MB memory. Files are automatically named in YYMMDD_HHMMSS format, thanks to the new RTC function.

6.6 Setting Date and Time (RTC)
The device includes a Real-Time Clock (RTC) for accurate timestamping of saved data. You can set the date and time through the device's menu.

6.7 Dynamic Range Display
The device provides a clear dynamic range display for accurate signal analysis.

7. Konserwacja
- Czyszczenie: Do czyszczenia urządzenia używaj miękkiej, suchej ściereczki. Unikaj stosowania silnych środków chemicznych i materiałów ściernych.
- Składowanie: Store the DeepVNA 101 in its protective case when not in use to prevent damage. Keep it in a cool, dry place away from direct sunlight and extreme temperatures.
- Pielęgnacja baterii: Aby zapewnić optymalną żywotność baterii, unikaj częstego całkowitego rozładowywania. Regularnie ładuj urządzenie, nawet jeśli nie jest aktywnie używane, aby utrzymać baterię w dobrym stanie.
8. Rozwiązywanie Problemów
- Urządzenie się nie włącza: Upewnij się, że bateria jest naładowana. Podłącz urządzenie do źródła zasilania za pomocą kabla typu C i spróbuj ponownie.
- Ekran dotykowy nie reaguje: If a screen protector is installed, try removing it as it may interfere with the resistive touch functionality. Ensure the screen is clean and dry.
- Niedokładne pomiary: Perform a calibration using the provided calibration pieces (OPEN, SHORT, LOAD) before critical measurements. Ensure all connections are secure.
- Problemy z oprogramowaniem sprzętowym: Check the official support webwitryna zawierająca najnowsze aktualizacje oprogramowania sprzętowego i instrukcje instalacji.
9. Wskazówki użytkownika
- Kalibracja jest kluczowa: Always perform a proper calibration with the provided OPEN, SHORT, and LOAD standards before taking measurements, especially when changing frequency ranges or cables, to ensure accuracy.
- Etui ochronne: Utilize the included EVA protective bag to safeguard your device during transport and storage.
- Rotary Encoder vs. Touch: Experiment with both the rotary encoder and touch screen for navigation to find your preferred method for different tasks. The rotary encoder can offer more precise control for fine adjustments.
10. Gwarancja i wsparcie
For detailed instructions, PC software, and further support, please visit the official DEEPELEC webstrona:
- Urzędnik Webstrona: https://deepelec.com/
- Strona wsparcia: https://deepelec.com/support/
You can also connect with the community and find additional resources through:
- Groups.io: groups.io/g/nanovna-f
- Facebook: NanoVNA-F