VEVOR YS-059A

VEVOR 7.5L Manual Transmission Fluid Pump

Model: YS-059A

1. Informacje dotyczące bezpieczeństwa

Read and understand all safety warnings and instructions before operating this fluid pump. Failure to follow these instructions may result in property damage or personal injury.

  • Always wear appropriate personal protective equipment, including safety glasses and gloves, when handling automotive fluids.
  • Ensure the work area is well-ventilated to avoid inhaling hazardous fumes.
  • Do not use this pump with corrosive or highly flammable liquids. Refer to the fluid manufacturer's safety data sheet (SDS) for proper handling.
  • Trzymaj dzieci i osoby nieupoważnione z dala od obszaru pracy.
  • Zużyte płyny i materiały czyszczące należy utylizować zgodnie z lokalnymi przepisami ochrony środowiska.
  • Check all connections for leaks before and during operation.

2. Koniec produktuview

The VEVOR 7.5L Manual Transmission Fluid Pump is designed for efficient and clean transfer of various automotive fluids, including transmission fluid, engine oil, brake fluid, gear lubricants, coolant, and power steering fluid. Its manual piston design ensures precise control and leak-secure operation.

2.1 Zawartość pudełka

  • 1 x Transmission Fluid Pump (7.5L Tank)
  • 1 x Outlet Hose with Shut-off Valve (120 cm / 47 in)
  • 1 x Rocker (Pump Handle)
  • 8 x ATF Adapters
  • Śrubokręt 1 x Phillips
  • 1 x klucz płaski
  • 2 x Cross Bolts with Lock Nuts (M6x20)
  • 1 x Instrukcja obsługi

2.2 Główne cechy

  • 7.5 L Capacity Tank: Large, clear HDPE reservoir allows for monitoring fluid levels and supports multiple applications without frequent refilling.
  • Leak-Secure Operation: Features a brass flow valve and multi-seal internals for a tight internal oil path and steady pressure, minimizing spills.
  • Fast Pumping Power: Long-lever, piston design enhances stroke volume with less effort for quicker fluid transfer.
  • Precise Fit Adapters: Includes 8 metal ATF fill adapters compatible with various vehicle brands like Ford, BMW, VW/Audi, Honda, and Nissan.
  • Trwała konstrukcja: HDPE reservoir resists oil and chemicals, while reinforced metal adapters ensure longevity.
VEVOR 7.5L Manual Transmission Fluid Pump with hose and adapters

Image: The VEVOR 7.5L Manual Transmission Fluid Pump, showing the main tank, pump handle, and included accessories.

3. Instrukcje konfiguracji

Follow these steps to assemble and prepare your fluid pump for use.

  1. Zainstaluj uchwyt: Attach the rocker (pump handle) to the top of the pump unit using the provided cross bolts and lock nuts. Ensure it is securely fastened.
  2. Open and Fill: Unscrew the top cap of the 7.5L tank. Carefully pour the desired fluid into the tank. Do not overfill; leave some space for air. Securely close the cap.
  3. Connect Hose and Adapter: Connect the outlet hose to the pump's output port. Select the appropriate ATF adapter for your vehicle's transmission fill port. Connect the adapter to the end of the outlet hose. Ensure all connections are tight to prevent leaks.
  4. Position for Transfer: Place the pump on a stable, level surface. Insert the adapter into the vehicle's transmission fill port.
  5. Prepare for Pumping: Ensure the shut-off valve on the outlet hose is in the closed position before starting to pump.
Five steps for setting up and using the VEVOR fluid pump: install handle, fill tank, connect hose and adapter, open valve, and pump.

Image: Visual guide illustrating the five key steps for setting up and preparing the fluid pump for operation.

4. Instrukcja obsługi

This section details the process for transferring fluids using the VEVOR pump.

  1. Sprawdź połączenia: Double-check that all hose and adapter connections are secure and leak-free.
  2. Open Shut-off Valve: Once the adapter is securely in the vehicle's fill port, open the shut-off valve on the outlet hose to allow fluid flow.
  3. Rozpocznij pompowanie: Operate the pump handle (rocker) with steady, consistent strokes. The piston design will draw fluid from the tank and push it through the hose into the vehicle's system.
  4. Monitoruj poziom płynu: Observe the fluid level in the transparent tank and the vehicle's fill indicator (if applicable) to prevent overfilling. The clear tank allows for easy monitoring.
  5. Stop Transfer: Once the desired fluid level is reached, close the shut-off valve on the outlet hose.
  6. Usuń adapter: Carefully remove the adapter from the vehicle's fill port. Be prepared for any residual drips.
Mechanic using the VEVOR fluid pump to refill transmission fluid under a car

Image: The VEVOR fluid pump in operation, demonstrating fluid refilling under a vehicle with the long leverage handle and piston pump.

4.1 Adapter Selection

The kit includes 8 different ATF adapters to ensure compatibility with a wide range of vehicle makes and models. Refer to your vehicle's service manual to identify the correct adapter for your specific application.

  • ATF101: Bród
  • ATF102: Universal Interface (BMW, Nissan, Honda, etc.)
  • ATF103: Proprietary Interface (Audi, VW, Skoda)
  • ATF104: Proprietary Interface (Porsche, VW, Audi)
  • ATF105: M10x1 (VW, Mini Cooper, Audi)
  • ATF106: M24x1.5 (VW DSG, Audi)
  • ATF107: M22x1.5 (VW CVT, Audi)
  • ATF109: M12x1.5 (ALTIS 2010, BENZ 722.9)
Close-up of the 8 included ATF adapters with their corresponding vehicle compatibility

Image: A display of the eight different ATF adapters included with the pump, showing their unique designs and compatible vehicle brands.

5. Konserwacja

Proper maintenance ensures the longevity and reliable performance of your fluid pump.

5.1 Czyszczenie

  • After each use, especially when changing fluid types, clean the tank, hose, and adapters thoroughly.
  • Flush the pump and hose with a suitable cleaning agent or a small amount of the new fluid to remove residues.
  • Wipe down the exterior of the pump and tank with a clean cloth.
  • Ensure all components are dry before storage to prevent corrosion or contamination.
Close-up of the pump's tight-fit connectors, sealed PU hose, and leak-proof brass control valve

Image: Details of the pump's sealed components, including tight-fit connectors, a sealed and durable PU hose, and a leak-proof brass control valve, which contribute to a clean workspace.

5.2 Przechowywanie

  • Przechowuj pompę w czystym i suchym miejscu, z dala od bezpośredniego światła słonecznego i ekstremalnych temperatur.
  • Keep the adapters organized in their case to prevent loss or damage.
  • Ensure the tank is empty and clean before long-term storage.
Images showing the rugged HDPE tank, kink-resistant PU hose, and reinforced metal fittings of the VEVOR fluid pump

Image: Components highlighting the pump's durability, including the rugged HDPE tank, kink-resistant PU hose, and reinforced metal fittings, designed for demanding shop environments.

6. Rozwiązywanie Problemów

W tej sekcji omówiono typowe problemy, które mogą wystąpić w trakcie użytkowania urządzenia.

ProblemMożliwa przyczynaRozwiązanie
Fluid not pumping or low pressure
  • Zawór odcinający zamknięty
  • Luźne połączenia
  • Wyciek powietrza w układzie
  • Zbiornik pusty
  • Pump mechanism issue
  • Otwórz zawór odcinający.
  • Tighten all hose and adapter connections.
  • Check for cracks in the hose or tank.
  • Refill the tank with fluid.
  • Inspect the piston and seals for damage.
Wycieki płynu z połączeń
  • Luźne połączenia
  • Uszkodzone pierścienie uszczelniające lub uszczelki
  • Zastosowano nieprawidłowy adapter
  • Mocno dokręć wszystkie połączenia.
  • Sprawdź i wymień wszelkie uszkodzone pierścienie uszczelniające lub uszczelki.
  • Ensure the correct adapter is used and properly seated.
Trudności z przymocowaniem adaptera
  • Incorrect adapter selected
  • Debris in port or adapter
  • Verify the correct adapter for your vehicle.
  • Clean the vehicle's fill port and the adapter.

7. Specyfikacje

FunkcjaSzczegół
Numer modelu przedmiotuYS-059A
Pojemność7.5 l (1.98 galona amerykańskiego)
Metoda rozładowaniaManual Piston Press with Flow Control Valve
Materiał głównyHDPE (polietylen o wysokiej gęstości)
Waga produktu3.1 kg (6.61 funta)
Wymiary produktu (dł. x szer. x wys.)290 × 520 × 495 mm (11.42 × 20.47 × 19.49 cala)
Długość węża wylotowego120 cm (47 cala)
Dołączone adaptery8 ATF Adapters (1/8"-27, M10x1.0, M24x1.5, M22x1.5, M12x1.5, etc.)
VEVOR fluid pump with a list of its technical specifications

Image: The VEVOR fluid pump displayed alongside its detailed technical specifications, including model number, capacity, and dimensions.

8. Informacje o gwarancji

Aby uzyskać szczegółowe informacje dotyczące gwarancji, zapoznaj się z kartą gwarancyjną dołączoną do produktu lub odwiedź oficjalną stronę internetową VEVOR webZachowaj paragon jako dowód zakupu na wypadek ewentualnych roszczeń gwarancyjnych.

9. Wsparcie

If you have any questions, require technical assistance, or need to report an issue with your VEVOR Transmission Fluid Pump, please contact VEVOR customer support. Contact information can typically be found on the VEVOR official webmiejscu lub w opakowaniu produktu.

Aby uzyskać dodatkowe zasoby i informacje o produkcie, odwiedź stronę Sklep VEVOR na Amazon.

Ask a question about this manual