1. Koniec produktuview
The KING LPWV2715-CT24 is a robust, vandal-resistant electric heater designed for high-traffic and public areas such as detention facilities, public restrooms, and rest areas. Its heavy-duty construction, including a 3/16-inch solid steel frame and grill, provides exceptional durability against impact and abuse. Tamper-resistant screws secure the grill, and controls are recessed to prevent unauthorized access. This unit offers moderate wattage and high airflow to effectively heat entryways and hallways, preventing drafts from affecting the building's core temperature.

Obraz 1: Przód view of the KING LPWV2715-CT24 Vandal Resistant Heater, showcasing its robust metal casing and grill.
Główne cechy:
- Impact/Vandal Resistant: Constructed with a heavy grill and 3/16-inch solid steel frame.
- Pic-A-Watt Elements: Allows for multiple wattagOpcje dostosowane do konkretnych wymagań grzewczych.
- Tamper Resistant 3 Position Switch: Offers Fan, Heat, and Off settings, designed to prevent unauthorized adjustments.
- Zabezpieczenie przed przegrzaniem: Integrated safety feature to prevent overheating.
2. Informacje dotyczące bezpieczeństwa
Read all instructions carefully before installing or using this heater. Failure to follow these instructions may result in electric shock, fire, property damage, or personal injury.
- Instalacja elektryczna: This heater operates on 277 Volts and requires hardwiring. Installation must be performed by a qualified electrician in accordance with all national and local electrical codes.
- Grunt: This heater must be properly grounded to reduce the risk of electric shock.
- Lokalizacja: Do not install the heater in areas where gasoline, paint, or other flammable liquids are stored or used. Maintain proper clearances from combustible materials as specified in the installation section.
- Zabezpieczenie przed przegrzaniem: The heater is equipped with a thermal cut-out to prevent overheating. If the heater shuts off due to overheating, allow it to cool down before attempting to restart. Investigate and correct the cause of overheating.
- Nie zakrywaj: Never cover the heater or block its air inlets/outlets. This can cause overheating and fire.
- Konserwacja: Przed przystąpieniem do czynności konserwacyjnych lub czyszczenia należy odłączyć zasilanie.
3. Zawartość opakowania
Przed otwarciem opakowania należy sprawdzić, czy wszystkie elementy są obecne i nieuszkodzone:
- KING LPWV2715-CT24 Vandal Resistant Heater Unit
- Mounting Hardware (typically included)
- Instrukcja obsługi (ten dokument)
Jeśli brakuje jakichkolwiek elementów lub są one uszkodzone, należy natychmiast skontaktować się z dostawcą.
4. Instalacja
OSTRZEŻENIE: Installation must be performed by a qualified electrician. Disconnect all power to the circuit at the main service panel before attempting any wiring.
4.1 Miejsce montażu
- This heater is designed for indoor, wall-mount installation.
- Choose a location that allows for proper air circulation and maintains required clearances from walls, ceilings, and floors. Refer to local codes for specific clearance requirements.
- Ensure the mounting surface is structurally sound to support the heater's weight (approximately 36 pounds).
4.2 Podłączenie elektryczne
- The LPWV2715-CT24 heater requires a dedicated 277 Volt, 60 Hz, single-phase circuit.
- Grzejnik pobiera 5.4 Amps at 277V, providing 1500 Watts of heat. Ensure the circuit breaker and wiring are appropriately sized for this load.
- Connect the heater directly to the electrical supply using appropriate hardwiring methods and connectors, following the wiring diagram provided inside the heater's access panel.
- Sprawdź, czy wszystkie połączenia są dobrze dokręcone i bezpieczne.
5. Działanie
Once properly installed and powered, the heater can be operated using its tamper-resistant 3-position switch.
5.1 ustawienia przełącznika zasilania
- OFF: The heater is completely off, and no heat or fan operation will occur.
- WENTYLATOR: The fan operates continuously without engaging the heating elements. This can be used for air circulation.
- CIEPŁO: The heating elements and fan operate to provide warmth. The heater will cycle on and off to maintain the desired temperature if connected to an external thermostat (not included).
5.2 WtagWybór e (Pic-A-Watt)
The LPWV series heaters feature Pic-A-Watt elements, allowing for field-adjustable wattage settings. Refer to the wiring diagram inside the heater for instructions on how to adjust the wattage to suit specific room requirements. This adjustment should only be performed by a qualified technician with power disconnected.
6. Konserwacja
Regularna konserwacja zapewnia optymalną wydajność i długowieczność ogrzewacza. Przed przystąpieniem do jakichkolwiek prac konserwacyjnych należy zawsze odłączyć zasilanie od wyłącznika automatycznego.
- Czyszczenie: Okresowo czyść zewnętrzną część grzejnika miękką,amp ściereczka. Nie należy używać środków czyszczących o właściwościach ściernych ani rozpuszczalników.
- Wloty/wyloty powietrza: Ensure that the air inlets and outlets are free from dust, lint, and other obstructions. Use a vacuum cleaner with a brush attachment to gently clean the grill and internal components if accessible.
- Kontrola: Annually inspect the heater for any signs of damage, loose wiring, or unusual wear. If any issues are found, contact a qualified electrician for repair.
7. Rozwiązywanie Problemów
Przed skontaktowaniem się z obsługą klienta,view następujące typowe problemy i rozwiązania:
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Grzejnik nie włącza się. | No power supply; Circuit breaker tripped; Loose wiring. | Check circuit breaker; Ensure power switch is in 'HEAT' or 'FAN' position; Consult a qualified electrician to check wiring. |
| Heater produces no heat, but fan runs. | Switch in 'FAN' position; Heating elements failed; Overheat protection activated. | Set switch to 'HEAT'; Allow heater to cool if overheat protection tripped; Contact a qualified electrician for element inspection. |
| Ogrzewanie włącza się i wyłącza często. | Improper thermostat setting (if applicable); Restricted airflow; Overheat protection cycling. | Adjust thermostat setting; Clear any obstructions from air inlets/outlets; Ensure proper clearances. |
| Nietypowe dźwięki lub zapachy. | Loose components; Dust accumulation on elements; Motor issue. | Disconnect power immediately; Inspect for loose parts; Clean heater; Contact a qualified electrician for inspection. |
Jeśli po wypróbowaniu tych rozwiązań problem nadal występuje, skontaktuj się z działem obsługi klienta lub wykwalifikowanym elektrykiem.
8. Specyfikacje
| Specyfikacja | Szczegół |
|---|---|
| Marka | KRÓL |
| Numer modelu | LPWV2715-CT24 |
| Tomtage | 277 wolty |
| Ampwymazać | 5.4 Amps |
| Cotage | 1500 watów |
| Wymiary produktu (Gł. x Szer. x Wys.) | 4" gł. x 13.75" szer. x 22.75" wys. |
| Waga przedmiotu | 36 funta |
| Typ montażu | Montaż ścienny |
| Typ paliwa | Elektryczny |
| Zastosowanie wewnątrz/na zewnątrz | Wnętrz |
| Funkcja specjalna | Zabezpieczenie przed przegrzaniem |
| UPC | 093319183731 |
| ASIN | B0G3SWW2XK |
9. Gwarancja i wsparcie
For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or visit the official KING webZachowaj paragon jako dowód zakupu na wypadek reklamacji.
Producent: KING Electrical Manufacturing
Webstrona: www.king-electric.com (Byłyamplink, proszę sprawdzić oficjalny webteren)