ACE ICX7550-24P-E2-R3

Instrukcja obsługi przełącznika ACE Ruckus ICX7550-24P-E2-R3 24-portowego Gigabit PoE+

Model: ICX7550-24P-E2-R3

1. Wprowadzenie i koniecview

This manual provides essential information for the installation, operation, and maintenance of the ACE Ruckus ICX7550-24P-E2-R3 24-Port Gigabit PoE+ Switch. This high-performance 1U rack-mount managed switch offers 24 ports of 10/100/1000 Mbps PoE+ with a 1.2 kW power budget and two 40 Gigabit QSFP+ uplinks, along with a USB Type-C console. It is designed for enterprise campus, data center, and edge deployments, supporting IP phones, wireless access points, cameras, and IoT devices.

The ICX7550-24P-E2-R3 is built for high availability and scalability, featuring dual hot-swappable power supplies, redundant fans, and the ability to stack up to 12 switches. Its advanced Layer 2 and Layer 3 capabilities ensure secure, low-latency traffic for critical applications.

Przód view of multiple ACE Ruckus ICX7550-24P-E2-R3 switches stacked

Rycina 1: Przód view of ACE Ruckus ICX7550-24P-E2-R3 switches, showcasing 24 Gigabit PoE+ ports and 40G QSFP+ uplinks.

2. Główne cechy

  • 24 portów Gigabit PoE+: Provides 10/100/1000 Mbps connectivity with Power over Ethernet Plus, supporting a 1.2 kW power budget for connected devices.
  • 40G QSFP+ Uplinks: Two integrated 40 Gigabit QSFP+ ports for high-speed backbone connections and flexible network architecture.
  • USB Type-C Console: Modern console interface for local management and configuration.
  • Advanced Layer 2/3 Switching: Supports static routing, Multi-Chassis Link Aggregation Group (MLAG), Quality of Service (QoS), Access Control Lists (ACLs), IGMP snooping, and multicast for robust network control.
  • Możliwość układania w stosy: Allows stacking of up to 12 Ruckus switches for unified management, hitless upgrades, and scalable network expansion.
  • Wysoka dostępność: Equipped with dual hot-swappable power supplies and redundant fans to ensure continuous operation and minimize downtime.
  • Pamięć: Features 4 GB RAM and 4 GB flash memory for efficient operation and storage of configurations.
  • TAA Compliance: Meets Trade Agreements Act requirements, suitable for government deployments.

3. Zawartość opakowania

Verify that all items are present and undamaged upon unpacking. If any items are missing or damaged, contact your reseller immediately.

  • ACE Ruckus ICX7550-24P-E2-R3 Switch Unit
  • Power Cords (quantity may vary based on region)
  • Rack Mount Kit (brackets, screws)
  • Kabel konsolowy USB typu C
  • Documentation (e.g., Quick Start Guide, Safety Information)

4. Konfiguracja i instalacja

4.1 Fizyczna instalacja

  1. Montaż w szafie: Securely attach the provided rack mount brackets to the switch using the included screws. Install the switch into a standard 19-inch equipment rack, ensuring adequate ventilation space around the unit.
  2. Zagadnienia dotyczące ochrony środowiska: Ensure the installation environment meets the operating temperature and humidity requirements specified in the technical specifications. Avoid placing the switch near heat sources or in areas with excessive dust.

4.2 Połączenie zasilania

  1. Connect the power cords to the dual hot-swappable power supply units at the rear of the switch.
  2. Plug the other end of the power cords into grounded AC power outlets. The switch will power on automatically.

4.3 Połączenia sieciowe

  1. Urządzenia Ethernet: Connect your network devices (IP phones, wireless access points, cameras, computers) to the 24 Gigabit PoE+ ports using standard Ethernet cables.
  2. Połączenia wysyłające: Use appropriate QSFP+ transceivers and fiber optic cables to connect the two 40G QSFP+ uplink ports to your core network or other switches.

4.4 Połączenie z konsolą

  1. Connect the USB Type-C console cable from your management workstation to the USB-C console port on the switch for initial configuration and command-line interface (CLI) access.
Tył view of multiple ACE Ruckus ICX7550-24P-E2-R3 switches stacked, showing power supplies and fan modules

Rysunek 2: Tył view of ACE Ruckus ICX7550-24P-E2-R3 switches, highlighting the dual hot-swappable power supplies and fan modules.

5. Obsługa przełącznika

5.1 Pierwsze włączenie zasilania

Once connected to power, the switch will initiate its boot sequence. Observe the system status LEDs on the front panel to confirm successful startup.

5.2 Dostęp do interfejsu zarządzania

  • Command-Line Interface (CLI): Access via the USB Type-C console port or remotely via SSH after initial network configuration.
  • Web-Zarządzanie oparte na: Access the graphical user interface (GUI) by entering the switch's IP address into a web browser. The default IP address and login credentials can be found in the Quick Start Guide or product documentation.

5.3 Podstawowa konfiguracja

After accessing the management interface, perform essential configurations such as:

  • Setting the management IP address and subnet mask.
  • Configuring VLANs for network segmentation.
  • Enabling and configuring PoE settings for connected devices.
  • Setting up user accounts and access privileges.
  • Configuring time and date settings (NTP).

6. Konserwacja

6.1 aktualizacji oprogramowania sprzętowego

Regularly check the ACE or Ruckus Networks support website for the latest firmware versions. Updating the firmware ensures optimal performance, security, and access to new features. Follow the provided instructions carefully during the update process.

6.2 Czyszczenie i dbanie o środowisko

  • Keep the switch and its surroundings clean and free of dust. Dust accumulation can impede airflow and lead to overheating.
  • Do czyszczenia powierzchni zewnętrznej należy używać miękkiej, suchej ściereczki. Nie należy używać środków czyszczących w płynie ani w aerozolu.
  • Ensure proper airflow by keeping ventilation openings clear.

6.3 Monitorowanie stanu systemu

Regularly monitor the switch's health and performance through the management interface. Pay attention to system logs, port status, CPU utilization, and temperature readings to identify potential issues early.

7. Rozwiązywanie Problemów

This section provides basic troubleshooting steps for common issues. For more complex problems, refer to the comprehensive product documentation or contact technical support.

7.1 Problemy z zasilaniem

  • Brak zasilania: Verify that power cords are securely connected to both the switch and the power outlets. Check power outlet functionality.
  • Awaria zasilania: If one power supply fails, the other should maintain operation. Check the status LEDs for the power supplies. Replace faulty units if necessary.

7.2 Problemy z łącznością sieciową

  • Port Link nieczynny: Check the Ethernet cable connection to the device and the switch port. Verify the device is powered on and functioning.
  • Brak dostępu do sieci: Confirm IP address configuration, VLAN assignments, and routing settings. Check for IP address conflicts.

7.3 PoE Functionality Issues

  • Urządzenie nie otrzymuje zasilania: Ensure the connected device is PoE-compatible. Check PoE settings on the switch port. Verify the total PoE power budget is not exceeded.

7.4 Console Access Issues

  • Cannot Connect via USB-C: Ensure the correct USB driver is installed on your management workstation. Verify terminal emulator settings (e.g., baud rate, data bits, parity, stop bits).

8. Specyfikacje techniczne

FunkcjaSpecyfikacja
Numer modeluICX7550-24P-E2-R3
Porty24 x 10/100/1000 Mb/s PoE+
Porty uplinkowe2 x 40G QSFP+
Budżet mocy PoE1.2 kW (1123.7 W max draw)
Port konsoliUSB typu C
BARAN4 GB
Pamięć Flash4 GB
Współczynnik kształtuUchwyt do szafy 1U
ZasilaczeDual Hot-Swappable
Kompatybilne urządzeniaWi-Fi & Ethernet Devices
ProducentRUCKUS & ACE
UPC199240108239
Data pierwszej dostępności14 sierpnia 2025 r.

9. Gwarancja i wsparcie

For technical support, warranty information, or service requests, please refer to the official ACE or Ruckus Networks website or contact your authorized reseller. Keep your purchase receipt and product serial number readily available when seeking support.

© 2025 ACE. All rights reserved. Ruckus is a trademark of CommScope, Inc.

Powiązane dokumenty - ICX7550-24P-E2-R3

Przedview Instrukcja obsługi i specyfikacja techniczna przełącznika PoE Yuanley
W niniejszej instrukcji obsługi i specyfikacji technicznej znajdują się szczegółowe informacje na temat przełączników PoE Yuanley, w tym scenariusze zastosowań, objaśnienia dotyczące panelu przedniego i kompleksowe parametry techniczne różnych modeli.
Przedview INTELBRAS WC 7060 Series Access Controllers: Hardware Information and Specifications
Detailed hardware information, technical specifications, ports, and LED descriptions for the INTELBRAS WC 7060 Series Access Controllers. Includes removable components, power supplies, fan trays, and expansion modules.
Przedview AirLive POE-GSH420-60 – instrukcja szybkiej konfiguracji: 6-portowy przełącznik gigabitowy PoE+
Ten skrócony przewodnik konfiguracji zawiera instrukcje instalacji oraz szczegółowe informacje na temat kontrolek i przełączników funkcyjnych 6-portowego przełącznika gigabitowego AirLive POE-GSH420-60. Wspomniano w nim również o powiązanym modelu POE-GSH802M.
Przedview Instrukcja instalacji inteligentnego przełącznika NETGEAR 24-port Gigabit Ethernet PoE+ (GS724TPv3, GS724TPPv3)
Niniejszy podręcznik instalacji zawiera instrukcje dotyczące konfiguracji i zarządzania inteligentnymi przełącznikami NETGEAR 24-port Gigabit Ethernet PoE+, modelami GS724TPv3 i GS724TPPv3. Obejmuje on zawartość opakowania, kroki podłączania, sprawdzanie stanu PoE, metody wykrywania i zarządzania przełącznikami (NETGEAR Discovery Tool, interfejs użytkownika urządzenia, NETGEAR Insight), zagadnienia związane z PoE oraz rozwiązywanie problemów.
Przedview Instrukcja obsługi przełącznika PoE NICGIGA w wersji 4.0 — dane techniczne i funkcje
Instrukcja obsługi przełączników PoE NICGIGA (wersja 4.0) zawierająca szczegółowe scenariusze zastosowań, objaśnienia dotyczące panelu przedniego i kompleksowe specyfikacje techniczne modeli GS0410P, FS0820GP, GS0800P, AI-FS1621GP, GS1620P, FS2420GP, NIC-S25-0402P i NIC-S25-0801P.
Przedview Przewodnik po modułach transceiverów sieciowych FS: transceivery, przetworniki DAC i AOC dla kart sieciowych Intel
Kompleksowy przewodnik szczegółowo opisujący zgodność transceiverów FS, przetworników DAC i kart AOC z kartami sieciowymi opartymi na procesorach Intel. Zawiera listy obsługiwanych modułów i kabli dla różnych modeli kart sieciowych.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.