1. Wprowadzenie
Thank you for choosing the Protmex PTH-24E 4-in-1 Carbon Monoxide and Gas Detector. This device is designed to provide real-time monitoring of carbon monoxide (CO) and combustible gas levels, along with temperature and humidity, to enhance safety in your home or while traveling. Please read this manual carefully before use to ensure proper operation and safety.
2. Informacje dotyczące bezpieczeństwa
Carbon monoxide (CO) is a colorless, odorless, and tasteless gas that can be fatal. Combustible gases can also pose serious risks. This detector is an important safety device, but it is not a substitute for proper maintenance of fuel-burning appliances or ventilation systems. Always follow local regulations and safety guidelines.
- Nie należy blokować otworów wentylacyjnych urządzenia.
- Nie maluj urządzenia.
- Test the device regularly as per operating instructions.
- In case of an alarm, immediately ventilate the area and evacuate. Contact emergency services if necessary.
- Urządzenie jest przeznaczone wyłącznie do użytku wewnątrz pomieszczeń.
3. Koniec produktuview
The Protmex PTH-24E integrates multiple detection capabilities into a compact, plug-in design.
Główne cechy:
- Real-time monitoring of Carbon Monoxide (CO) and combustible gas.
- Integrated temperature and humidity monitoring.
- Large 2.0" P5 LCD display for clear readings.
- Dual semiconductor and electrochemical sensors for accuracy.
- Loud audible alarm (≥85dB) and visual flashing alarms.
- Plug-in design (110V-220V) with replaceable plug for versatility.
- Flame-retardant ABS plastic housing.

Figure 1: Protmex PTH-24E 4-in-1 CO and Combustible Gas Detector. This image highlights the device's capabilities including CO and gas detection, temperature and humidity monitoring, and its plug-in design.
4. Konfiguracja
The Protmex PTH-24E is designed for easy, plug-and-play installation.
- Rozpakować: Ostrożnie wyjmij detektor z opakowania.
- Wybierz lokacje: Select a suitable location for the detector. For CO detection, place it near sleeping areas and on every level of your home. For gas detection, place it near gas-burning appliances (e.g., kitchen, fireplace). Ensure it is not obstructed by furniture or curtains.
- Włączać do kontaktu: Insert the detector directly into any standard 110V-220V electrical outlet. The device will power on automatically.
- Kalibracja początkowa: The device will perform an initial self-test and calibration upon first power-up. Allow a few minutes for the readings to stabilize.
Replaceable Plug:
The device features a replaceable plug, allowing it to be used with different outlet types. To change the plug, press the quick-release button, rotate the current plug to unlock, and replace it with the desired plug type. Ensure it locks securely into place.

Figure 2: Interchangeable Plug. The quick-release button allows for easy replacement of the plug, making the device compatible with various international outlets.
5. Instrukcja obsługi
The PTH-24E features three intuitive buttons for various functions:

Figure 3: Easy-to-Use Controls. This diagram illustrates the functions of the three buttons on the device for self-testing, unit toggling, alarm control, screen orientation, brightness, and gas sensitivity.
- "U" Button (Top):
- Short Press: Initiates a self-test of the device.
- Long Press: Toggles between Fahrenheit (°F) and Celsius (°C) for temperature display.
- Przycisk brzęczyka (prawy):
- Short Press: Turns the alarm sound on or off.
- Long Press: Flips the screen display 180 degrees, useful if the outlet orientation is inverted.
- Przycisk jasności ekranu (lewy):
- Short Press: Adjusts the screen brightness.
- Long Press: Switches between Gas Sensitivity 1 (S1) and Gas Sensitivity 2 (S2).
Verifying CO Detector Functionality:
To verify the CO detector is working properly, you can perform a simple test:
- Place a lit cigarette (or a source of CO, such as a small amount of smoke from a match) over the detector's back vent.
- Within 1-2 minutes, you should observe the CO value increase on the display.
- When the carbon monoxide concentration exceeds 50 PPM, the CO detector will sound an alarm. The CO value can display up to 999 PPM. This confirms the detector is working correctly.
Video 1: Protmex 4-in-1 CO Detector Plug-in Demonstration. This video shows the device being plugged into an outlet, demonstrating its compact size and the functionality of its display and buttons, including the screen flip feature and the display of temperature and humidity.
6. Wyświetlanie informacji
The large LCD screen provides clear, real-time data:
- CO PPM: Wyświetla stężenie tlenku węgla w cząsteczkach na milion.
- GAZ: Indicates the level of combustible gas detected. This is often represented by a colored bar or numerical value.
- Temperatura: Shows the ambient temperature in either Celsius or Fahrenheit.
- Wilgotność: Wyświetla wilgotność względną w procentachtage.
- Ikony alertów: Visual indicators for alarms (e.g., bell icon) and status (e.g., green for safe, yellow/orange for caution, red for danger).

Figure 4: Clear LCD Display. The image shows the detector's screen with readings for CO concentration, gas levels, temperature, and humidity, designed for ultimate clarity.
7. Konserwacja
To ensure optimal performance and longevity of your detector:
- Regularne czyszczenie: Delikatnie przetrzyj zewnętrzną część detektora miękką szmatką.amp płótno. Nie używaj ostrych środków chemicznych ani ściernych środków czyszczących.
- Utrzymuj otwory wentylacyjne w czystości: Ensure that the ventilation openings on the device are free from dust, debris, or obstructions.
- Unikaj ekstremalnych warunków: Do not expose the detector to direct sunlight, high humidity, or extreme temperatures outside its operating range (14°F to 122°F / -10°C to 50°C).
- Testuj regularnie: Perform the self-test function weekly or monthly to confirm proper operation.
8. Rozwiązywanie Problemów
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Alarm sounds frequently without apparent cause. | High CO/Gas levels, sensor malfunction, or false alarm. | Immediately ventilate the area and evacuate. If safe, check for gas leaks. If alarms persist without a clear cause, contact emergency services or a qualified technician. |
| Wyświetlacz jest pusty lub nie odpowiada. | Brak zasilania, awaria urządzenia. | Ensure the device is securely plugged into a working outlet. Try a different outlet. If the issue persists, contact customer support. |
| Niedokładne odczyty temperatury/wilgotności. | Device placed near heat/cold source, blocked sensors. | Relocate the device away from direct heat sources, vents, or windows. Ensure sensors are not obstructed. |
9. Specyfikacje
- Model produktu: PTH-24E
- Wejście Voltage: 100-220 V
- Źródło zasilania: Elektryczny przewodowy
- Temperatura pracy: od -14°C do 122°C (od 10°F do 50°F)
- Głośność alarmu: ≥85dB
- Zakres detekcji CO: 0-999 str./min
- Wykrywanie gazu: 5% DGW (dolna granica wybuchowości)
- Wymiary produktu: 1.18" gł. x 2.99" szer. x 2.76" wys. (30 mm gł. x 76 mm szer. x 70 mm wys.)
- Waga przedmiotu: 0.22 funta (ok. 100 g)
- Tworzywo: Flame-retardant ABS Plastic
- Certyfikaty: CE, FC, UL, RoHS

Figure 5: Detector in Use. The image shows the compact design of the detector plugged into a standard wall outlet, providing continuous monitoring.
10. Gwarancja i wsparcie
The Protmex PTH-24E Carbon Monoxide and Gas Detector comes with a 48-miesięczna gwarancja producenta. For any product inquiries, technical support, or warranty claims, please contact Protmex customer service through the details provided on the product packaging or the official Protmex webstrona.
Producent: Protmex International Group Co., Ltd.