Wstęp
This manual provides detailed instructions for the proper assembly, operation, maintenance, and troubleshooting of your HUTACT NHKJ-3J5-893 Compound Biology Microscope. Please read this manual thoroughly before using the microscope to ensure optimal performance and longevity of the instrument.

Rysunek 1: The HUTACT NHKJ-3J5-893 Compound Biology Microscope, shown with its various components and included accessories such as eyepieces, objective lenses, prepared slides, and a storage bag.
Zawartość opakowania
Sprawdź, czy w przesyłce znajdują się wszystkie wymienione poniżej elementy:
- HUTACT Compound Biology Microscope
- Eyepieces: H10X, H25X
- Objective Lenses: 4X, 10X, 40X
- 2X Magnification Lens (Barlow lens)
- Set of 5 Prepared Microscope Slides
- Torba do przechowywania
- Ściereczka do czyszczenia
- Instrukcja obsługi (ten dokument)

Rysunek 2: A visual representation of the items included in the microscope package, such as the microscope body, lens group, microscope slide set, instructions, cleaning cloth, storage bag, and packaging box.
Instrukcje konfiguracji
- Rozpakowywanie: Ostrożnie wyjmij wszystkie elementy z opakowania. Zachowaj opakowanie do późniejszego przechowywania lub transportu.
- Umieszczenie: Place the microscope on a stable, flat surface in a well-lit area.
- Montaż okularu: Insert the desired eyepiece (H10X or H25X) into the top of the monocular tube.
- Objective Lens Selection: Rotate the revolving nosepiece to select the 4X objective lens. This is the lowest magnification and is recommended for initial observation.
- Powering the Illumination: The microscope uses LED illumination. Ensure that the necessary AAA batteries (not included) are installed in the battery compartment located at the base of the microscope.
- Regulacja oświetlenia: Turn on the LED light source using the switch, and adjust its intensity if available.
Obsługa mikroskopu
1. Preparing a Specimen Slide
Use one of the included prepared slides or prepare your own specimen on a clean glass slide. Place the slide onto the stage, zabezpieczając go za pomocą stagklipy elektroniczne.

Rysunek 3: A set of prepared microscope slides, demonstrating the variety of specimens that can be observed, along with examples powiększonych views.
2. Skupienie
- Initial Focus (Low Power): With the 4X objective lens in place, look through the eyepiece. Use the coarse focus knob (larger knob) to bring the specimen into approximate focus.
- Fine Focus (High Power): Once the specimen is roughly in focus with the 4X objective, rotate the revolving nosepiece to a higher magnification objective (10X or 40X). Use the fine focus knob (smaller knob) for precise focusing.
- Regulacja oświetlenia: Adjust the LED light source and diaphragm to achieve optimal brightness and contrast for your specimen.

Rysunek 4: Examples of magnified images at 40X, 200X, and 2000X, illustrating the microscope's capability to reveal intricate details of biological specimens.
3. Zmiana powiększenia
To change magnification, simply rotate the revolving nosepiece to the desired objective lens. The microscope is parfocal, meaning that once focused at one magnification, the specimen should remain largely in focus when switching to another objective, requiring only minor adjustments with the fine focus knob.
For maximum magnification up to 2000X, you can insert the 2X magnification lens (Barlow lens) between the eyepiece and the monocular tube, in conjunction with the H25X eyepiece and 40X objective lens.
Konserwacja i pielęgnacja
- Czyszczenie soczewek: Use the provided cleaning cloth or a specialized lens cleaning paper to gently wipe objective lenses and eyepieces. Avoid touching optical surfaces with bare hands.
- Czyszczenie ciała: Przetrzyj korpus mikroskopu miękką,amp płótno. Nie używaj ostrych środków chemicznych ani ściernych środków czyszczących.
- Składowanie: When not in use, cover the microscope with a dust cover or store it in the provided storage bag to protect it from dust and moisture.
- Wymiana baterii: Replace AAA batteries when the LED illumination becomes dim.
- Obsługiwanie: Always carry the microscope by its arm and base to ensure stability.
Rozwiązywanie problemów
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Brak oświetlenia | Baterie są rozładowane lub nieprawidłowo zainstalowane. | Check battery orientation and replace with fresh AAA batteries. |
| Obraz jest rozmazany lub nieostry | Incorrect focus adjustment; objective lens not properly engaged. | Adjust coarse and fine focus knobs. Ensure objective lens clicks into place. |
| Dark spots or dust in view | Dust on eyepiece, objective lens, or specimen slide. | Clean eyepiece, objective lens, and slide using a cleaning cloth. |
| Difficulty seeing specimen at high magnification | Insufficient illumination; specimen too thick; incorrect focus. | Increase LED brightness. Ensure specimen is thin enough for light to pass through. Refocus carefully. |
Specyfikacje
- Całkowite powiększenie: 40X-2000X
- Okulary: H10X, H25X
- Soczewki obiektywowe: 4X, 10X, 40X (Achromatic)
- Magnification Multiplier: 2X (Barlow Lens)
- Observation Head: Monocular Vertical Tube
- Nosek: Potrójny obrotowy nosek
- System ustawiania ostrości: Coarse adjustment range of 16 mm
- Stage: 90 x 90 mm with Slide Clips
- Źródło światła: Oświetlenie LED
- Microscope Dimensions: Wymiary 11 x 16.1 x 27 cm
- Masa netto: 0.76 kilogramów
- Materiał korpusu: Stop aluminium
- Numer modelu: NHKJ-3J5-893
Gwarancja i wsparcie
For warranty information or technical support, please refer to the contact details provided with your purchase documentation or visit the official HUTACT webZachowaj paragon jako dowód zakupu na wypadek reklamacji.
This product is designed for educational and exploratory purposes. For any issues not covered in this manual, please contact customer support.