Banner Engineering M18TUP14

Instrukcja obsługi czujnika temperatury przemysłowej M18TUP14

Model: M18TUP14 | Brand: Banner Engineering

1. Wprowadzenie i koniecview

The Banner Engineering M18TUP14 is an industrial temperature sensor designed for precise temperature measurement in various industrial applications. This sensor features a 1 Germanium Lens, providing accurate readings within a temperature range of -20°C to +300°C. It offers an analog 0-10V output for continuous temperature monitoring and a PNP alarm output for threshold detection. The robust design, including an IP67 rating, ensures reliable performance in demanding environments. This manual provides essential information for the safe and effective installation, operation, and maintenance of your M18TUP14 sensor.

2. Informacje dotyczące bezpieczeństwa

Read all instructions carefully before installing or operating the M18TUP14 sensor. Failure to follow these instructions may result in product damage, property damage, or serious injury.

3. Zawartość opakowania

Sprawdź, czy po rozpakowaniu wszystkie elementy są obecne i nieuszkodzone:

If any components are missing or damaged, contact your supplier immediately.

4. Specyfikacje

ModelM18TUP14
ProducentInżynieria banerów
Zakres temperatur-20°C do +300°C (-4°F do +572°F)
Objętość zasilania operacyjnegotage12V do 30V prądu stałego
Typ wyjściaAnalog 0-10V, PNP Alarm
Typ soczewki1 Germanium Lens
Długość kabla2 metrów (6.5 stóp)
Stopień ochrony IPIP67
Waga przedmiotu6.99 funta (ok. 3.17 kg)

5. Konfiguracja i instalacja

Proper installation is crucial for the accurate and reliable operation of the M18TUP14 sensor.

5.1 Montaż

The M18TUP14 sensor features an M18 threaded barrel for easy mounting. Use appropriate mounting hardware (not included) to secure the sensor in the desired location. Ensure the sensor's lens is unobstructed and has a clear line of sight to the target area for temperature measurement. The IP67 rating ensures protection against dust and temporary immersion in water, making it suitable for harsh industrial environments.

M18TUP14 Industrial Temperature Sensor showing its threaded body, power and output indicators, and TEACH button.

Figure 1: M18TUP14 Industrial Temperature Sensor. The image displays the cylindrical, threaded body of the sensor, with a black end housing the power (PWR) and output (OUT) indicator LEDs, and a 'TEACH' button. The sensor terminates in a threaded connector for wiring.

5.2 Okablowanie

Connect the sensor to your control system according to the following general guidelines. Refer to the specific wiring diagram provided with your sensor for detailed connections. Ensure power is OFF before wiring.

6. Działanie

Once installed and wired, the M18TUP14 sensor is ready for operation.

6.1 Power-Up and Indicators

Upon applying power, the PWR (Power) indicator LED on the sensor will illuminate, typically green, indicating that the sensor is receiving power. The NA ZEWNĄTRZ (Output) indicator LED will illuminate when the PNP alarm output is active (i.e., when the measured temperature exceeds the set alarm threshold).

6.2 Analog Output Reading

The 0-10V analog output provides a continuous representation of the measured temperature. You will need to scale this voltage reading in your control system (PLC, HMI, etc.) to convert it into a temperature value (e.g., degrees Celsius or Fahrenheit) based on the sensor's specified temperature range (-20°C to +300°C).

Na przykładample, 0V might correspond to -20°C and 10V to +300°C. Consult the sensor's data sheet for the exact scaling factor if not provided here.

6.3 Setting Alarm Threshold (TEACH Function)

The 'TEACH' button on the sensor is used to set the PNP alarm threshold. The exact procedure may vary slightly, but typically involves:

  1. Place the sensor in the environment or at the temperature you wish to set as the alarm threshold.
  2. Press and hold the 'TEACH' button for a specified duration (e.g., 2-5 seconds) until the OUT indicator flashes, indicating it has learned the new threshold.
  3. Release the button. The sensor is now configured, and the PNP alarm will activate when the temperature exceeds this newly taught value.

Refer to the detailed programming instructions in the full Banner Engineering product manual for advanced teaching modes or specific timing requirements.

7. Konserwacja

The M18TUP14 sensor is designed for minimal maintenance. However, periodic checks can ensure optimal performance and longevity.

8. Rozwiązywanie Problemów

If you encounter issues with your M18TUP14 sensor, consider the following common troubleshooting steps:

ProblemMożliwa przyczynaRozwiązanie
Brak zasilania (dioda LED zasilania wyłączona)Brak zasilania; Nieprawidłowe okablowanie; Wadliwe zasilanie.Sprawdź połączenia zasilania i głośnośćtage (12-30V DC). Verify wiring polarity. Test power supply.
Incorrect Analog Output ReadingSensor lens obstructed/dirty; Incorrect scaling in controller; Sensor outside temperature range.Clean sensor lens. Verify scaling parameters in your control system. Ensure target temperature is within -20°C to +300°C.
PNP Alarm Not TriggeringIncorrect alarm threshold set; Wiring issue; Temperature not reaching threshold.Re-teach the alarm threshold using the 'TEACH' button. Check PNP output wiring. Verify actual temperature.
Odczyty przerywaneLoose wiring connections; Electrical interference; Unstable power supply.Secure all wiring connections. Ensure proper grounding. Use shielded cables if interference is suspected.

If the problem persists after attempting these steps, contact Banner Engineering technical support or your authorized distributor for further assistance.

9. Gwarancja i wsparcie

For information regarding the warranty of your M18TUP14 Industrial Temperature Sensor, please refer to the warranty statement provided by Banner Engineering or contact your point of purchase (e.g., Neutron USA). Technical support and additional resources can typically be found on the official Banner Engineering webna stronie internetowej lub kontaktując się z działem obsługi klienta.

Producent: Inżynieria banerów

ASIN: B0F4JSFBPY

Powiązane dokumenty - M18TUP14

Przedview Czujnik temperatury T-GAGE na podczerwień serii Banner M18T z wyjściem analogowym
Szczegółowe informacje na temat czujnika temperatury na podczerwień T-GAGE serii Banner M18T, w tym funkcje, modele, specyfikacje, okablowanie, konfiguracja i konserwacja.
Przedview Banner T-GAGE M18T Series Infrared Temperature Sensors: Features, Specifications, and Applications
Comprehensive guide to Banner Engineering's T-GAGE M18T Series Infrared Temperature Sensors, detailing features, model specifications, sensing capabilities, programming methods, dimensions, and accessories for industrial temperature measurement.
Przedview Czujnik temperatury T-GAGE® serii Banner M18T z wyjściami dyskretnymi | Dane techniczne
Szczegółowe specyfikacje techniczne, funkcje, zastosowania i przewodnik konfiguracji czujnika temperatury T-GAGE® z serii Banner M18T z wyjściami dyskretnymi. Zawiera schematy okablowania, konfigurację czujnika i informacje dotyczące pomocy technicznej.
Przedview Taśma świetlna LED WLS70 Industrial (AC) – instrukcja obsługi i specyfikacja produktu
Kompleksowa instrukcja obsługi i specyfikacja przemysłowej taśmy LED Banner WLS70 (AC), szczegółowo opisująca funkcje, instalację, dane techniczne, akcesoria i gwarancję. Niniejszy przewodnik zawiera niezbędne informacje dotyczące zastosowań przemysłowych i w trudnych warunkach środowiskowych.
Przedview Instrukcja obsługi czujnika radarowego Q90R R-GAGE® | Banner Engineering
Kompleksowa instrukcja obsługi czujnika radarowego Banner Q90R R-GAGE®, obejmująca opis produktu, instalację, konfigurację, specyfikacje i wsparcie techniczne. Dowiedz się, jak skonfigurować i używać tego przemysłowego czujnika radarowego.
Przedview Konwerter wyjścia analogowego Banner R45C na urządzenie IO-Link: Szybki przewodnik
Skrócona instrukcja obsługi konwertera wyjścia analogowego na urządzenie IO-Link Banner R45C. Dowiedz się więcej o konfiguracji, instalacji, specyfikacji i rozwiązywaniu problemów tego wytrzymałego, przemysłowego konwertera czujników o stopniu ochrony IP.