This manual provides essential instructions for the safe and efficient use of your Jauarta 5V 1A UPS Uninterruptible Power Supply Module. This module is designed to provide a stable 5V 1A output, powered by either an external 5V input or a connected lithium battery, ensuring continuous operation for your devices.
Główne cechy obejmują:
- Moc wyjściowa: Provides a maximum output of 5V 1A.
- Przepełnienietage Ochrona: Automatically cuts off input when it exceeds 6V, switching to battery power.
- Ochrona przed odwrotną polaryzacją: Includes protection against reverse connection for both input and output.
- Zabezpieczenie przed zwarciem: Built-in protection against output short circuits.
- Jednoczesne ładowanie i rozładowywanie: Supports charging the battery while simultaneously supplying power to the load.
Ważne informacje dotyczące bezpieczeństwa
- Polaryzacja baterii: The positive and negative electrodes of the battery must not be reversed. Reversing polarity will damage the module.
- Wejście Voltage: Upewnij się, że głośność wejściowatage does not exceed 20V. Exceeding 20V can cause damage to the unit.
- Okablowanie: Due to potentially large currents, it is recommended to use thicker wires. The wire cross-section should be greater than 1.5mm².
- Prąd wyjściowy: The maximum output current is 1A, but continuous 1A output may not be sustained under all conditions.
- Środowisko operacyjne: Operate within the specified temperature range of -40°C to 85°C and humidity range of 0-95%RH.
Specyfikacje
| Parametr | Wartość |
|---|---|
| Typ przedmiotu | Moduł zasilacza |
| Tworzywo | Płytka drukowana |
| Wejście Voltage | 5V 1A |
| Objętość wyjściatage | 5 V 1 A (maksymalnie) |
| Moc wyjściowa | 5W |
| Zasilanie bateryjne | Polymer Lithium Battery, Lithium Battery (Recommended Capacity Below 10000mA) |
| Zabezpieczenie przed odwrotnym podłączeniem wejścia | Tak |
| Wejście Overvoltage Ochrona | Tak |
| Output Reverse Connection Protection | Tak |
| Zabezpieczenie przed zwarciem na wyjściu | Tak |
| Zakres temperatur pracy | -40°C do 85°C |
| Zakres wilgotności roboczej | 0-95% wilgotności względnej |
| Wymiary opakowania | 3.15 x 1.97 x 0.39 cala |
| Waga przedmiotu | 0.071 uncji |
| Numer modelu | Jauartau2ps7qya5o |
Zawartość opakowania
Pakiet zawiera:
- 1 x Jauarta 5V 1A UPS Uninterruptible Power Supply Module
Konfiguracja i połączenie
Follow these steps to set up your UPS module:
- Podłącz zasilanie wejściowe: Connect the correct 5V input voltage to the designated input terminals (N+ and N-). Ensure polarity is correct.
- Podłącz akumulator: Connect your polymer lithium battery or lithium battery to the B+ and B- terminals. Observe correct polarity to prevent module damage. The recommended battery capacity is below 10000mA.
- Sprawdź dane wyjściowe: Before connecting your load, you may check the output voltage with a voltmeter and current with an ammeter at the OUT+ and OUT- terminals.
- Podłącz obciążenie: Connect your 5V device to the OUT+ and OUT- terminals.

Obraz: widok z góry view of the Jauarta UPS module, highlighting the input (N+, N-), battery (B+, B-), and output (OUT+, OUT-) connection points.

Obraz: kątowy view of the Jauarta UPS module, providing a general perspective of its components and layout.
Instrukcja obsługi
The Jauarta UPS module operates automatically once connected. It will draw power from the 5V input when available and simultaneously charge the connected lithium battery. If the 5V input power is interrupted or falls below 6V, the module will seamlessly switch to drawing power from the connected battery to maintain a continuous 5V output to your device.
- Charging Indicator (Optional): Users can install a common anode red-green LED as a charging indicator. The red light indicates if the output terminal is loaded. The green light flashes to show battery capacity. If there is no load or battery, the green light will turn off.
- Power Continuity: The module ensures uninterrupted power supply during transitions between external power and battery power.
Konserwacja
The Jauarta UPS module is designed for low maintenance. To ensure optimal performance and longevity:
- Utrzymuj moduł w czystości, bez kurzu i zanieczyszczeń.
- Aby zapobiec przegrzaniu, należy zapewnić odpowiednią wentylację wokół modułu, zwłaszcza podczas pracy.
- Regularly inspect wiring for any signs of wear or damage.
- Store in a dry environment within the specified operating temperature and humidity ranges when not in use.
Rozwiązywanie problemów
If you encounter issues with your UPS module, consider the following:
- Brak mocy wyjściowej:
- Check if the input power is correctly connected and within the 5V range.
- Verify that the battery is connected with correct polarity and is charged.
- Ensure there is no short circuit at the output terminals.
- Uszkodzenie modułu:
- If the module is not functioning after initial connection, check if the battery or input power was connected with reversed polarity.
- Potwierdź, że wejściowa objtage did not exceed 20V at any point.
- Zasilanie przerywane:
- Ensure all wire connections are secure and that the wire thickness is adequate for the current draw (greater than 1.5mm² recommended).
- Check the battery health and capacity.
Jeśli problemy będą się powtarzać, skontaktuj się z obsługą klienta w celu uzyskania dalszej pomocy.
Gwarancja i wsparcie
This Jauarta product comes with a standard manufacturer's warranty. For specific warranty details, please refer to the product packaging or contact Jauarta customer support. For technical assistance or troubleshooting not covered in this manual, please reach out to our support team through the official Jauarta webna stronie internetowej lub u sprzedawcy.