1. Wprowadzenie
The DIGITEN THT1032 is a versatile temperature and humidity controller designed for precise environmental management. It features three independent outlets for controlling heating/cooling, humidification/dehumidification, and timed operations. Equipped with dual high-precision probes, this device is suitable for various applications including reptile enclosures, mushroom cultivation, plant seeding, and home brewing.
2. Główne cechy
- Działanie typu „podłącz i używaj”: Simple setup with intuitive buttons for quick configuration.
- Dual High-Precision Probes: Separate probes for temperature (accuracy: ±0.4°C/±0.7°F) and humidity (accuracy: ±3%).
- Triple-Zone Precision Control: Three independent outlets for temperature, humidity, and timed devices.
- Duży wyświetlacz LCD: Clear, real-time monitoring with switchable Fahrenheit/Celsius units.
- Climate Customization: Combine heating/cooling with humidification/dehumidification, and program the third outlet for timers.
3. Zawartość opakowania
- DIGITEN THT1032 Controller Unit
- Sonda temperatury
- Sonda wilgotności
- Instrukcja obsługi
4. Koniec produktuview
The DIGITEN THT1032 controller features a main unit with a large LCD display, control buttons, three power outlets, and two external probes for temperature and humidity sensing.

Obraz 1: Przód view of the DIGITEN THT1032 controller, showing the display, buttons, and three power outlets.
4.1. Panel sterowania i wyświetlacz
The front panel includes an LCD screen and four control buttons: SET, MODE, Up (▲), and Down (▼).

Rysunek 2: Szczegółowy view of the controller's outlets and control buttons. OUT1 is for temperature, OUT2 for humidity, and OUT3 for timer functions.
- Przycisk SET: Used to select an outlet for configuration or confirm settings.
- Przycisk TRYB: Used to change the operating mode (e.g., heating/cooling, humidification/dehumidification, timer program).
- Przycisk w górę (▲): Zwiększa wartości lub umożliwia nawigację po opcjach menu.
- Przycisk w dół (▼): Zmniejsza wartości lub umożliwia nawigację po opcjach menu.
- WYJŚCIE1: Temperature controlled outlet.
- WYJŚCIE2: Humidity controlled outlet.
- WYJŚCIE3: Timer controlled outlet.
4.2. Sondy
The controller comes with two separate probes: one for temperature and one for humidity. These probes are essential for accurate environmental monitoring.

Image 3: The temperature probe (left) and humidity probe (right) connected to the controller, illustrating their distinct functions.
5. Konfiguracja początkowa
- Podłącz sondy: Plug the temperature probe and humidity probe into their respective ports on the controller. Ensure they are securely connected.
- Umieszczenie: Position the probes in the environment you wish to monitor and control. Ensure they are not directly exposed to heat sources, moisture, or airflow that could skew readings.
- Włączanie: Plug the controller into a standard 120V AC power outlet. The display will illuminate, showing current temperature, humidity, and time.
- Podłącz urządzenia: Plug your heating/cooling device into OUT1, your humidification/dehumidification device into OUT2, and any timed appliance (e.g., lights, misters) into OUT3.
6. Instrukcja obsługi
6.1. Setting Temperature Control (OUT1)
- Naciśnij USTAWIĆ button repeatedly until OUT1 is selected (indicated by a flashing OUT1 icon or similar).
- Użyj W górę (▲) or W dół (▼) przyciski umożliwiające ustawienie pożądanej temperatury docelowej.
- Naciskać TRYB to cycle through heating (HEAT) or cooling (COOL) modes. Select the appropriate mode for your connected device.
- Naciskać USTAWIĆ to confirm the temperature and mode.
- To set the temperature differential (hysteresis), press and hold USTAWIĆ for a few seconds when OUT1 is selected. Use W górę/w dół to adjust the difference between the set point and when the device turns on/off. Press USTAWIĆ aby potwierdzić.
6.2. Setting Humidity Control (OUT2)
- Naciśnij USTAWIĆ button repeatedly until OUT2 is selected.
- Użyj W górę (▲) or W dół (▼) buttons to adjust the desired target humidity percentage.
- Naciskać TRYB to cycle through humidification (HUMIDIFICATION) or dehumidification (DEHUMIDIFICATION) modes. Select the appropriate mode.
- Naciskać USTAWIĆ to confirm the humidity and mode.
- To set the humidity differential, press and hold USTAWIĆ for a few seconds when OUT2 is selected. Use W górę/w dół Aby dostosować. Naciśnij USTAWIĆ aby potwierdzić.
6.3. Setting Timer Control (OUT3)
- Naciśnij USTAWIĆ button repeatedly until OUT3 is selected.
- Naciskać TRYB to enter the timer programming interface.
- Używać W górę (▲) or W dół (▼) to set the ON time (hour and minute). Press USTAWIĆ aby przejść do następnego ustawienia.
- Ustaw czas WYŁĄCZENIA (godzinę i minutę) za pomocą W górę/w dół I USTAWIĆ.
- The controller supports multiple ON/OFF programs for OUT3. Refer to the on-screen prompts for additional program slots.
- Naciskać USTAWIĆ aby zapisać i wyjść z ustawień timera.
6.4. Przełączanie jednostek temperatury (°C/°F)
To switch between Celsius and Fahrenheit, press and hold the W górę (▲) button for approximately 3 seconds. The display will change accordingly.
7. Konserwacja
- Czyszczenie: Przetrzyj jednostkę sterującą miękką, suchą ściereczką. Nie używaj środków czyszczących o właściwościach ściernych ani nie zanurzaj jednostki w wodzie.
- Pielęgnacja sondy: Keep the probes clean and free from debris. Avoid bending or damaging the probe cables. If probes become dirty, gently clean them with a damp cloth and allow them to dry completely before re-use.
- Składowanie: Gdy kontroler nie jest używany, należy przechowywać go w chłodnym, suchym miejscu, z dala od bezpośredniego światła słonecznego i ekstremalnych temperatur.
8. Rozwiązywanie Problemów
| Wydanie | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Wyświetlacz jest pusty lub nie włącza się. | Brak zasilania; luźne połączenie. | Ensure the controller is securely plugged into a live power outlet. Check the power source. |
| OUT1/OUT2/OUT3 not activating connected device. | Incorrect settings; device malfunction; power issue. | Verify temperature/humidity/timer settings. Check if the connected device is working independently. Ensure the controller's set point is met for activation. |
| Humidity probe shows "ERR" reading. | Probe malfunction; damaged cable; sensor error. | Check the humidity probe connection. Inspect the probe cable for damage. If the error persists, the probe may need replacement. |
| Niedokładne odczyty temperatury/wilgotności. | Probe placement; dirty probe; probe malfunction. | Relocate probes away from direct heat/moisture/airflow. Clean probes gently. If issues persist, consider probe replacement. |
9. Specyfikacje techniczne
| Specyfikacja | Wartość |
|---|---|
| Numer modelu | THT1032 |
| Wymagania dotyczące zasilania | 100-240 V AC |
| Nośność | 10A per outlet (1100W@110V, 2200W@220V) |
| Zakres regulacji temperatury | -10°C do 120°C / 14°F do 248°F |
| Dokładność temperatury | ± 0.4 ° C / ± 0.7 ° F |
| Dokładność wilgotności | ±3% |
| Typ czujnika sondy | Digital Signal Output, I2C Interface |
| Temperatura otoczenia roboczego | 0-50°C / 32-122°F |
| Wilgotność względna środowiska pracy | <85% |
| Typ wyświetlacza | LCD |
| Tworzywo | Plastikowy |
| Kolor | Szary |
| Waga przedmiotu | 1.04 funta |
| Wymiary opakowania | 6.85 x 6.34 x 1.93 cala |
10. Gwarancja i obsługa klienta
DIGITEN provides a one-year warranty for any quality-related issues with this product. For technical assistance, troubleshooting, or warranty claims, please contact DIGITEN customer support through the retailer where the product was purchased or visit the official DIGITEN webwitryna do informacji kontaktowych.
Zachowaj dowód zakupu, aby skorzystać z serwisu gwarancyjnego.