Wstęp
Thank you for choosing the Aideepen USB-C Power Meter and Protocol Tester. This device is designed for precise measurement and monitoring of USB-C power delivery, supporting various fast charging protocols. Its robust construction and intuitive display make it an essential tool for tech enthusiasts and professionals.
This manual provides detailed instructions on how to set up, operate, and maintain your device, ensuring optimal performance and longevity.
Produkt ponadview
The Aideepen USB-C Power Meter features a 1.14-inch HD IPS display housed in a durable CNC metal case, offering dustproof and drop-resistant properties. It provides real-time data for voltage, current, power, and supports various fast charging protocols.

Image: The USB-C Power Meter's display showing real-time voltage, current, and power readings, along with protocol information.
Główne cechy:
- High-Definition IPS Display: 1.14-inch screen for clear, real-time data visualization.
- Trwała konstrukcja: CNC metal casing provides dustproof and drop-resistant protection.
- One-Touch Page Switching: Easily navigate between three multi-functional display pages.
- Professional Measurement: Includes curve measurement, ripple measurement, and comprehensive protocol testing.
- Obsługa szerokiego protokołu: Compatible with PD2.0/3.0, PPS, QC2.0/3.0, FCP, SCP, AFC, PE, DASH, VOOC, SuperVooc.
- Stable & Safe: Utilizes reliable Type-C voltage and current detection technology for secure monitoring.
- Automatyczne obracanie ekranu: Built-in gravity sensor for convenient vieworientacja.
Układ urządzenia:

Image: Diagram illustrating the device's buttons and ports. The device features a USB-C input and output, along with control buttons on the side.
- Przycisk powrotu: Returns to the previous menu or main page.
- Przycisk OK: Potwierdza wybór lub przechodzi do podmenu.
- Przyciski w lewo/w prawo: Navigates between display pages or selects options within menus.
- Przełącznik WYŁ./WŁ.: Wyłącznik zasilania urządzenia.
Organizować coś
The Aideepen USB-C Power Meter is designed for plug-and-play operation. No complex setup is required.
- Włączanie: Ensure the OFF/ON switch on the side of the device is in the 'ON' position.
- Podłącz do źródła zasilania: Plug the USB-C input of the tester into your power adapter or power bank.
- Podłącz urządzenie: Plug your USB-C device (e.g., smartphone, tablet, laptop) into the USB-C output of the tester.
- Rozpocznij monitorowanie: The device will automatically power on and begin displaying real-time voltage, current, and power data.
Instrukcja obsługi
The tester offers multiple display modes and functions accessible via its side buttons.
Switching Display Pages:
The device has three main display pages. Use the Left/Right buttons aby je przejrzeć:
- Page 1: Real-time Data Display
Shows current direction, voltage, current, power, charging protocol, handshake position, and data line voltage (D+, D-, CC1, CC2). - Page 2: Capacity Statistics & Max Values
Wyświetla objętośćtage, current, power, charging protocol, capacity statistics (automatically saved when powered off), maximum voltage, current, power, and MCU chip real-time temperature. - Page 3: Curve Display
Presents voltage and current as curves on a unit grid, sampling time, current direction, real-time curve plotting, voltage, prąd i moc.

Image: The three main display pages of the USB-C Power Meter, showing real-time data, accumulated statistics, and a voltage/current curve graph.
Przełączanie języka:
To switch the display language (Chinese/English):

Image: Visual guide for navigating the menu to change the display language from Chinese to English.
- From the main display, press the Przycisk powrotu to enter the 'Menu' screen.
- Użyj Left/Right buttons to select '3 Setting' and press the Przycisk OK aby wejść do interfejsu ustawień.
- Select 'Language' using the Left/Right buttons i naciśnij OK. Użyj Left/Right buttons to switch between languages. After successful switching, press OK jeszcze raz, aby potwierdzić.
- Po zakończeniu ustawień naciśnij przycisk Przycisk powrotu to exit the settings interface and return to normal operation.
Protocol Testing:
The device supports various protocol tests, including Auto-Test and PD Single Cheat. Navigate to the 'Protocol' menu option to access these features.

Image: The protocol test menu, showing options like 'Auto-Test' and 'PD Single Cheat' for advanced power delivery analysis.
For detailed protocol testing, refer to the on-screen prompts and use the OK I Left/Right buttons to navigate and select options. The device will display supported protocols (green) and unsupported protocols (red).
Bidirectional Current Detection:
The tester supports bidirectional current detection, allowing you to monitor power flow regardless of the connection orientation.

Image: The device demonstrating its ability to detect current flow in both directions, useful for various charging setups.
Konserwacja
- Czyszczenie: Do czyszczenia urządzenia należy używać miękkiej, suchej ściereczki. Unikaj stosowania środków czyszczących o właściwościach ściernych i rozpuszczalników.
- Składowanie: Przechowywać urządzenie w chłodnym i suchym miejscu, z dala od bezpośredniego światła słonecznego i ekstremalnych temperatur.
- Obsługiwanie: While the device is drop-resistant, avoid unnecessary impacts to prevent damage to internal components or the display.
- Aktualizacje oprogramowania układowego: Check the official Aideepen webodwiedź tę witrynę, aby uzyskać dostęp do aktualizacji oprogramowania sprzętowego i zapewnić optymalną wydajność i kompatybilność.
Rozwiązywanie problemów
- Brak wyświetlacza/zasilania:
Ensure the OFF/ON switch is in the 'ON' position. Verify that the power source is active and providing power to the tester. Try a different USB-C cable or power source. - Nieprawidłowe odczyty:
Ensure all connections are secure. Some cables or devices may not fully support certain fast charging protocols, leading to lower than expected readings. Test with known good cables and devices. - Display Frozen/Unresponsive:
Try turning the device off and then on again using the OFF/ON switch. If the issue persists, disconnect all power, wait a few seconds, and reconnect. - Language Issue:
Follow the 'Language Switching' instructions in the Operating section to set your preferred language.
Specyfikacje
| Funkcja | Specyfikacja |
|---|---|
| Marka | Aideepen |
| Numer modelu | KBAI0058-AAB |
| Wejście/Wyjście Objętośćtage Zakres | DC 4-30V |
| Zakres prądu | 0-12A |
| Zakres mocy | 0-360W |
| Wyświetlacz | 1.14-inch HD IPS Color Screen |
| Obsługiwane protokoły | PD2.0/3.0, PPS, QC2.0/3.0, FCP, SCP, AFC, PE, DASH, VOOC, SuperVooc |
| Wymiary (w przybliżeniu) | 54.96 mm x 24.45 mm x 11.15 mm (2.16 cala x 0.96 cala x 0.44 cala) |
| Kolor | Czarny |
| Pochodzenie | Chiny |

Image: Detailed dimensions of the Aideepen USB-C Power Meter.
Gwarancja i wsparcie
This Aideepen product comes with a 180-dniowa gwarancja Gwarancja obowiązuje od daty zakupu i obejmuje wady produkcyjne. Prosimy zachować dowód zakupu na wypadek roszczeń gwarancyjnych.
For technical support, troubleshooting assistance, or warranty inquiries, please contact Aideepen customer service through the retailer's platform or visit the official Aideepen webwitryna do informacji kontaktowych.
Naszym celem jest dostarczanie naszym klientom produktów i wsparcia najwyższej jakości.