RAB Lighting B17

Instrukcja obsługi słupka oświetleniowego LED B17 firmy RAB Lighting

Model: B17

1. Wprowadzenie

This manual provides detailed instructions for the installation, operation, and maintenance of the RAB Lighting B17 LED Bollard Light. This outdoor luminaire features field-adjustable wattage and selectable color temperature (CCT), designed for various outdoor applications.

Główne cechy obejmują:

  • Energy-efficient LED with a 50,000-hour lifespan.
  • Regulowana wodatage: 24W, 19W, or 14W.
  • Selectable CCT: 3000K (Warm White), 4000K (Neutral White), or 5000K (Cool White).
  • 0-10V dimming capability.
  • Dopuszczenie UL dla miejsc mokrych.
  • Durable metal construction with a glass shade.
RAB Lighting B17 LED Bollard Light

Figure 1: RAB Lighting B17 LED Bollard Light (Model B17D shown).

2. Informacje dotyczące bezpieczeństwa

OSTRZEŻENIE: Risk of electric shock. Disconnect power before installation or servicing. Installation should be performed by a qualified electrician in accordance with all applicable national and local electrical codes.

  • Zapewnij objętość podażytage is correct for the fixture.
  • Do not handle live components.
  • Stosuj odpowiedni sprzęt ochrony osobistej (PPE).
  • This fixture is suitable for wet locations. Ensure all connections are properly sealed to prevent water ingress.
  • Nie modyfikuj urządzenia. Wszelkie modyfikacje mogą unieważnić gwarancję i stwarzać zagrożenie dla bezpieczeństwa.

3. Zawartość opakowania

Przed rozpoczęciem instalacji sprawdź, czy wszystkie komponenty są obecne:

  • B17 LED Bollard Light Fixture
  • On-Off Switch (Included Components)
  • Installation Hardware (e.g., mounting bolts, gaskets) - (Assumed, not explicitly listed but typical for such products)
  • Instrukcja obsługi (ten dokument)

4. Konfiguracja i instalacja

Follow these steps for proper installation of the B17 LED Bollard Light:

  1. Przygotuj miejsce instalacji: Ensure the mounting surface is stable and level. Run electrical conduit and wiring to the desired location according to local codes.
  2. Odłącz zasilanie: Przed rozpoczęciem jakichkolwiek prac elektrycznych należy wyłączyć zasilanie za pomocą wyłącznika automatycznego.
  3. Mount the Bollard: Secure the bollard base to the mounting surface using appropriate hardware. Ensure a watertight seal if required by local codes.
  4. Wykonaj połączenia elektryczne: Connect the fixture's wires to the supply wires. Follow standard wiring practices:
    • Black to Line (L)
    • Biały do ​​neutralnego (N)
    • Green/Ground to Ground (G)
    • Purple to Dimming (+) (for 0-10V dimming)
    • Gray to Dimming (-) (for 0-10V dimming)
    Upewnij się, że wszystkie połączenia są bezpieczne i izolowane.
  5. Wybierz Wattage i CCT: Before closing the fixture, adjust the wattage and CCT switches located inside the fixture head. Refer to Section 5 for details.
  6. Secure the Fixture Head: Attach the fixture head to the bollard body, ensuring all seals are properly seated to maintain the wet location rating.
  7. Przywróć zasilanie: Turn on power at the circuit breaker and test the light.
UL Listed and Wet Location Rated symbols

Figure 2: The B17 Bollard Light is UL Listed and rated for wet locations, ensuring durability in outdoor environments.

5. Instrukcja obsługi

5.1. Field-Adjustable Wattage

The B17 bollard light allows you to select the desired wattage output to optimize brightness and energy consumption. A switch located inside the fixture head enables selection between 24W, 19W, and 14W.

  • 24W: Maksymalna jasność.
  • 19W: Medium brightness, reduced energy use.
  • 14W: Lower brightness, maximum energy savings.

Aby dostosować: Disconnect power. Open the fixture head. Locate the wattage selection switch and move it to the desired setting. Close the fixture head and restore power.

5.2. Selectable Color Temperature (CCT)

The fixture offers three color temperature options to suit different aesthetic preferences and applications. A separate switch inside the fixture head allows selection between 3000K, 4000K, and 5000K.

  • 3000K: Warm White, ideal for creating a cozy and inviting atmosphere.
  • 4000K: Neutral White, suitable for general illumination and task lighting.
  • 5000K: Cool White, provides bright, crisp light, often used for security or modern aesthetics.

Aby dostosować: Disconnect power. Open the fixture head. Locate the CCT selection switch and move it to the desired setting. Close the fixture head and restore power.

Image showing 14W, 19W, 24W wattage options and 3000K, 4000K, 5000K CCT options for the bollard light

Figure 3: Visual representation of adjustable wattage and selectable CCT settings.

5.3. 0-10V Dimming

The B17 bollard light is compatible with 0-10V dimming systems. Connect the purple and gray dimming wires to a compatible 0-10V dimmer control. This allows for smooth adjustment of light output from 100% down to 10% (or lower, depending on dimmer specifications).

Ensure the dimmer is rated for LED loads and is compatible with 0-10V dimming protocols.

6. Konserwacja

The B17 LED Bollard Light is designed for minimal maintenance due to its long LED lifespan of 50,000 hours.

  • Czyszczenie: Okresowo czyść zewnętrzną część urządzenia miękką,amp cloth to remove dirt and debris. Do not use abrasive cleaners or solvents. Ensure power is off before cleaning.
  • Kontrola: Annually inspect the fixture for any signs of damage, loose connections, or wear. Ensure all seals remain intact to maintain weather resistance.
  • Wymiana diody LED: LEDs are integrated and not user-replaceable. The long lifespan minimizes the need for replacement.
Image indicating a 50,000-hour lifespan for the LED bollard light

Figure 4: The B17 LED Bollard Light offers a long 50,000-hour operational lifespan.

7. Rozwiązywanie Problemów

ProblemMożliwa przyczynaRozwiązanie
Światło się nie włącza.Brak zasilania.
Luźne połączenie okablowania.
Niepoprawne wattage/CCT setting.
Check circuit breaker. Ensure power is on.
Sprawdź, czy wszystkie połączenia przewodów są stabilne (najpierw wyłącz zasilanie).
Potwierdź cotage/CCT switches are set correctly.
Światło niespodziewanie migocze lub przygasa.Niekompatybilny ściemniacz.
Loose dimming wire connection.
Tomtage wahania.
Ensure 0-10V dimmer is compatible with LED loads.
Check purple and gray dimming wire connections.
Skonsultuj się z elektrykiem, aby sprawdzić stabilność zasilania.
Zbyt niski/wysoki poziom światła.Niepoprawne wattagustawienie.Dostosuj wattage selection switch inside the fixture head (power off first).
Light color is not desired.Nieprawidłowe ustawienie CCT.Adjust the CCT selection switch inside the fixture head (power off first).

8. Specyfikacje

FunkcjaSzczegół
Nazwa modeluB17
MarkaOświetlenie RAB
CotageField-Adjustable: 24W / 19W / 14W
Temperatura barwowa (CCT)Selectable: 3000K / 4000K / 5000K
ŚciemnianieMożliwość przyciemniania 0-10 V
Długość życia50,000 godziny
TworzywoMetal body, Glass shade
Ocena środowiskowaUL Listed for Wet Locations
Zawarte komponentyPrzełącznik włącz / wyłącz
UPC192552028424
ASINB0DY2FPPNS

9. Gwarancja i wsparcie

For warranty information and technical support, please contact RAB Lighting directly. Refer to the official RAB Lighting webSzczegółowe warunki gwarancji i dane kontaktowe znajdziesz na stronie internetowej lub w dokumentacji zakupu.

RAB Lighting Contact: www.ralighting.com

© 2025 RAB Lighting. Wszelkie prawa zastrzeżone.