KORAD KA3005P-23

KORAD KA3005P-23 Programmable DC Linear Power Supply User Manual

Model: KA3005P-23

Wstęp

This manual provides detailed instructions for the safe and efficient operation of the KORAD KA3005P-23 Programmable Precision Variable Adjustable DC Linear Power Supply. The KA-Series offers a reliable and accurate power source for various applications in labs, colleges, and production environments. Please read this manual thoroughly before using the device.

Cechy jednostki

KORAD KA3005P-23 Unit Features Overview

Obraz: Ponadview of the KORAD KA3005P-23 power supply highlighting its key features such as power and protection, memory settings, bright 4-digit LED display, and switchable power input.

  • Reliable & Precise Output: Provides a linear regulated benchtop power supply with precision adjustable voltage and current output (up to 30V/5A).
  • Kompaktowa konstrukcja: Features an intelligent temperature-controlled fan for cooling and low-noise operation.
  • W pełni programowalny: Allows saving and recalling up to four settings (M1-M4). Control options include USB, RS232, RS485, and MODBUS. Coarse/fine controls enable easy adjustment of voltagi aktualne.
  • Wielorakie zabezpieczenia: Obejmuje nadmiar objętościtage protection (OVP), over-current protection (OCP), reverse polarity protection, and short circuit protection to safeguard connected devices and the power supply itself.
  • Bright 4-Digit LED Display: Offers clear and precise readout of voltage i aktualne wartości.
  • Przełączane wejście zasilania: Easily switchable from 110V to 220V via a switch on the rear panel.
  • Keyboard LOCK Function: Zapobiega przypadkowym zmianom ustawień w trakcie działania.

Panel nadview

KORAD KA3005P-23 Front Panel Controls

Obraz: Szczegółowy view of the KORAD KA3005P-23 front panel, labeling all controls, indicators, and ports.

Elementy sterujące i wskaźniki na panelu przednim:

  • Tomtage Wyświetlacz (V): Pokazuje aktualną objętość wyjściowątage.
  • Aktualny wyświetlacz (A): Shows the current output ampwymazać
  • Memory Recall/Save Buttons (M1-M4): Used to store and recall preset voltage i aktualne wartości.
  • Przycisk ZABLOKOWANIA/ODBLOKOWANIA: Engages or disengages the front panel lock function.
  • Przycisk BEEP: Toggles the keypad beep sound.
  • Przycisk OVP: Przełącza nadmierną głośnośćtage Ochrona.
  • Przycisk OCP: Toggles Over-Current Protection.
  • Przycisk WYŁ./WŁ.: Steruje mocą wyjściową.
  • Pokrętło REGULACJI: Enkoder obrotowy do regulacji głośnościtage i aktualne wartości.
  • Digit Selector Buttons (< / >): Selects the digit to adjust with the ADJUST knob.
  • TOMTAGE/CURRENT Button: Przełącza między głośnościątagi aktualne tryby regulacji.
  • Output Terminals (+, -, GND): Podłącz tutaj obciążenie.
  • Indicators (OVP, OCP, M1-M4, C.C, C.V, OUT, LOCK): Display various operational statuses and active protections.

Organizować coś

Rozpakowanie i kontrola:

Upon receiving your KORAD KA3005P-23, carefully inspect the packaging for any signs of damage. Open the box and verify that all components are present:

  • KORAD KA3005P-23 Power Supply Unit
  • Instrukcja obsługi (ten dokument)
  • Kabel zasilający
  • Płyta CD z oprogramowaniem (jeśli dotyczy)
  • Kabel USB

Jeśli brakuje jakichkolwiek elementów lub są one uszkodzone, należy natychmiast skontaktować się z dostawcą.

Umieszczenie:

Place the power supply on a stable, level surface with adequate ventilation. Ensure that the fan vents on the rear and sides are not obstructed to allow for proper cooling.

Podłączenie zasilania:

  1. Ensure the power switch on the rear panel is set to the correct local voltage (110 V lub 220 V).
  2. Connect the provided power cable to the AC inlet on the rear of the unit.
  3. Plug the other end of the power cable into a grounded AC outlet.

Instrukcja obsługi

Podstawowa obsługa:

  1. Włączanie: Press the main power switch on the front panel. The LED display will illuminate.
  2. Ustaw objętośćtage:
    • Naciśnij TOMTAGE/BIEŻĄCY button until the voltage display is active (usually indicated by a flashing digit or cursor).
    • Użyj < I > digit selector buttons to choose the digit you wish to adjust.
    • Obróć REGULOWAĆ knob to set the desired voltage.
  3. Set Current Limit:
    • Naciśnij TOMTAGE/BIEŻĄCY button until the current display is active.
    • Użyj < I > digit selector buttons to choose the digit.
    • Obróć REGULOWAĆ knob to set the desired current limit.
  4. Podłącz obciążenie: Ensure the output is OFF (OUT indicator is off). Connect your device to the output terminals (+, -, GND).
  5. Włącz wyjście: Naciśnij WYŁ./WŁ. button to enable the output. The OUT indicator will illuminate, and power will be supplied to your load.

Funkcje pamięci (M1-M4):

The unit allows you to store and recall up to four sets of voltage i bieżące ustawienia.

  1. Zapisywanie ustawień:
    • Ustaw żądaną głośnośćtagi aktualne.
    • Naciśnij i przytrzymaj jeden z M1-M4 buttons for approximately 3 seconds until a beep sounds, indicating the settings are saved.
  2. Przywoływanie ustawień:
    • Naciśnij krótko żądany przycisk M1-M4 button. The stored voltage and current values will be loaded.

Funkcje ochronne:

  • Over-voltage Ochrona (OVP): Naciśnij OVP button to enable/disable. When enabled, if the output voltage exceeds a preset limit, the output will shut down to protect the load.
  • Zabezpieczenie nadprądowe (OCP): Naciśnij OCP button to enable/disable. When enabled, if the output current exceeds a preset limit, the output will shut down.
  • Blokada klawiatury: Naciśnij ZABLOKUJ ODBLOKUJ button to prevent accidental changes to settings. The LOCK indicator will light up when active.

Programowalna kontrola

KORAD KA3005P-23 connected to a laptop via USB

Image: The KORAD KA3005P-23 power supply connected to a laptop, demonstrating its programmable control capabilities via USB or RS232 interface.

The KORAD KA3005P-23 can be controlled remotely via a computer using its USB or RS232 interfaces located on the rear panel. This allows for automated testing and precise control of output parameters.

  • Instalacja oprogramowania: Install the provided control software (usually on a CD or available for download from the manufacturer's web(strona) na Twoim komputerze.
  • Połączenie: Connect the power supply to your computer using either a USB cable or an RS232 serial cable.
  • Konfiguracja: Refer to the software's user manual for detailed instructions on configuring the communication port and controlling the power supply. The unit supports MODBUS protocol for advanced integration.

Specyfikacje

KORAD KA3005P-23 Unit Specifications Table

Image: A table detailing the technical specifications of the KORAD KA3005P-23 power supply, including voltage range, current range, load regulation, and ripple.

ParametrWartość
Tomtage Zakres0-30 V
Zakres prądu0-5A
Regulacja obciążenia (tomtage)≤0.01% + 2 mV
Regulacja obciążenia (prąd)≤0.1% + 10mA
Regulacja linii (tomtage)≤0.01% + 3 mV
Regulacja liniowa (aktualna)≤0.1% + 3mA
Rozdzielczość konfiguracji (tomtage)10mV
Rozdzielczość konfiguracji (bieżąca)1mA
Dokładność ustawienia (25°C ± 5°C) (obj.tage)≤0.5% + 20 mV
Dokładność konfiguracji (25°C ± 5°C) (aktualna)≤0.5% + 10mA
Ripple (20-20M) (tomtage)≤2mVrms
Tętnienie (20-20M) (prąd)≤2mVrms
Współczynnik temperaturowy (ttage)≤150 ppm
Współczynnik temperaturowy (prąd)≤150 ppm
Przeczytaj ponownie rezolucję (tomtage)10mV
Rozdzielczość odczytu (bieżąca)1mA
Czas reakcji (objętośćtag(e Rise)≤100mS
Czas reakcji (objętośćtage Upuść)≤100mS
InterfejsProgrammable Interface (USB, RS232)
Waga9.52 funta / 4.32 kg
Wymiary (dł. x szer. x wys.)10.5 x 4.4 x 6.5 cala (260 x 100 x 156 mm)
Moc wyjściowatage150 watów
Metoda chłodzeniaAir (Intelligent temperature-controlled fan)
Minimalna objętość wejściowatage110 V (AC)
KORAD KA3005P-23 Unit Dimensions

Image: Visual representation of the KORAD KA3005P-23 power supply with its dimensions and weight clearly indicated.

Konserwacja

  • Czyszczenie: Przed czyszczeniem odłącz zasilanie od gniazdka sieciowego. Do czyszczenia zewnętrznej części urządzenia użyj miękkiej, suchej ściereczki. Nie używaj środków czyszczących o właściwościach ściernych ani rozpuszczalników.
  • Wentylacja: Ensure the ventilation openings are kept clear of dust and debris to maintain proper cooling.
  • Składowanie: Jeśli urządzenie nie będzie używane przez dłuższy czas, należy je przechowywać w suchym i wolnym od kurzu miejscu.

Rozwiązywanie problemów

ProblemMożliwa przyczynaRozwiązanie
Brak zasilania po włączeniuPower cable not connected; AC outlet fault; Rear panel voltage switch incorrect; Internal fuse blown.Check power cable connection; Test AC outlet; Verify rear panel voltage switch setting; Contact service for fuse replacement.
Objętość wyjściowatage/current cannot be adjustedKeyboard LOCK function active; Incorrect adjustment mode selected.Press LOCK/UNLOCK button; Press VOLTAGE/CURRENT button to select desired adjustment mode.
Output shuts down unexpectedlyOVP or OCP triggered; Short circuit in load.Check OVP/OCP settings and disable if not needed; Inspect load for short circuits; Reduce output settings.
Fan is noisy or runs constantlyUnit is operating under heavy load; Ventilation obstructed.This is normal under heavy load; Ensure clear airflow around the unit.

Gwarancja i wsparcie

KORAD products are designed for reliability and precision. For warranty information, please refer to the warranty card included with your product or visit the official KORAD website. For technical support, troubleshooting assistance, or service inquiries, please contact your local distributor or KORAD customer service.

Please have your model number (KA3005P-23) and purchase date ready when contacting support.

© 2023 KORAD Technology. Wszelkie prawa zastrzeżone.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.