TOMZN TOMPD-63SW

Tomzn WiFi Smart Energy Meter and Leakage Current Protection Relay

Model: TOMPD-63SW

1. Koniec produktuview

The Tomzn TOMPD-63SW is a WiFi-enabled smart energy meter and leakage current protection relay designed to provide reliable protection and monitoring for your electrical installation. This 63A capacity device offers remote monitoring and control capabilities via a smartphone application. Its integrated LCD screen displays instantaneous voltage, current, and power consumption values. Featuring DIN rail mounting, it ensures easy installation within electrical panels. The device automatically disconnects the circuit in cases of over-voltage, pod objętościątage, or leakage current, safeguarding connected appliances. Through the mobile application, users can track energy consumption data and review historical records. It is an ideal solution for ensuring the safety of electrical devices in both residential and commercial environments, offering a compact design and user-friendly interface.

Tomzn WiFi Smart Energy Meter and Leakage Current Protection Relay, Model TOMPD-63SW

Zdjęcie przedstawiające przód view of the Tomzn WiFi Smart Energy Meter, highlighting its LCD display and compact design for DIN rail mounting.

2. Informacje dotyczące bezpieczeństwa

  • Zalecana profesjonalna instalacja: Aby zapewnić bezpieczeństwo i zgodność z lokalnymi przepisami elektrycznymi, instalację powinien wykonać wykwalifikowany elektryk.
  • Odłącz zasilanie: Always ensure the main power supply is disconnected before installing, maintaining, or servicing the device.
  • Tomtage i aktualne oceny: Nie przekraczaj określonej objętościtage and current ratings (63A) of the device.
  • Prawidłowe okablowanie: Ensure all wiring connections are secure and correctly terminated according to the wiring diagram. Loose connections can cause overheating or malfunction.
  • Warunki środowiskowe: Nie wystawiaj urządzenia na działanie wilgoci, ekstremalnych temperatur ani środowiska powodującego korozję.

3. Zawartość opakowania

Proszę sprawdzić, czy w paczce znajdują się następujące elementy:

  • Tomzn WiFi Smart Energy Meter and Leakage Current Protection Relay (Model TOMPD-63SW)
  • Instrukcja obsługi

4. Funkcje produktu

  • Inteligentne monitorowanie: Wi-Fi connectivity for remote tracking of energy consumption and voltage values via a mobile application.
  • Dane techniczne: 63A capacity, suitable for single-phase electrical systems, DIN rail mountable.
  • Funkcje ochronne: Automatic protection against over-voltage, pod objętościątage i prąd upływu.
  • Wyświetlacz LCD: Digital screen showing instantaneous voltage, current, and energy consumption values.
  • Instalacja: Easy and secure mounting onto electrical panels.

5. Specyfikacje

SpecyfikacjaWartość
ProducentTomzn
Numer referencyjny producentaTMZN01
Wymiary produktuWymiary 4.5 x 4.5 x 8.5 cm
Waga150 gramów
Typ złączaOtwór przelotowy
Obecna ocena63 Ampjesteś
Typ montażuSzyna DIN
MarkaTOMZN
Tryb pracyAutomatyczny

6. Instalacja (konfiguracja)

Ostrzeżenie: Instalację musi wykonać wykwalifikowany elektryk. Przed przystąpieniem do dalszych czynności upewnij się, że zasilanie jest odłączone.

  1. Odłączenie zasilania: Turn off the main power supply at the circuit breaker before starting any installation work. Verify that no voltage is present using a suitable testing device.
  2. Montowanie: Mount the TOMPD-63SW device onto a standard 35mm DIN rail within your electrical panel. Ensure it is securely fastened.
  3. Połączenia elektryczne:
    • Connect the incoming live (phase) wire to the L-IN terminal.
    • Connect the incoming neutral wire to the N-IN terminal.
    • Connect the outgoing live (phase) wire to the PROSTAK terminal, leading to your load.
    • Connect the outgoing neutral wire to the N-OUT terminal, leading to your load.
    • Ensure all connections are tight and correct according to the wiring diagram provided with the product.
  4. Przywrócenie zasilania: Once all connections are verified, restore the main power supply. The device's LCD screen should illuminate.
  5. Konfiguracja aplikacji: Download the designated mobile application (e.g., Tuya Smart or Smart Life, as commonly used for such devices) from your smartphone's app store. Follow the in-app instructions to add and configure the TOMPD-63SW device to your Wi-Fi network. This typically involves putting the device into pairing mode (refer to the device's specific button sequence for pairing).

7. Działanie

The TOMPD-63SW offers both local display and remote control/monitoring capabilities.

7.1. Wyświetlacz LCD

The integrated LCD screen provides real-time information:

  • Tomtage (v): Displays the instantaneous line voltage.
  • Prąd (A): Shows the instantaneous current flowing through the circuit.
  • Power (W/kW): Indicates the instantaneous active power consumption.
  • Energia (kWh): Accumulates total energy consumption.
  • Wskaźniki stanu: May show indicators for Wi-Fi connectivity, protection status (e.g., over-voltage, pod objętościątage, leakage current trip).

7.2. Kontrola aplikacji mobilnych

After successful app setup, you can:

  • Zdalne monitorowanie: View w czasie rzeczywistym, objtage, current, power, and energy consumption from anywhere.
  • Zdalne sterowanie: Turn the connected circuit ON or OFF remotely (if this feature is enabled for the specific model).
  • Ustawienia ochrony: Adjust parameters for over-voltage, pod objętościątage, and leakage current protection thresholds.
  • Dane historyczne: Access and analyze historical energy consumption data and event logs (e.g., protection trips).
  • Harmonogram: Set schedules or timers for the device to turn ON/OFF automatically.

8. Konserwacja

The Tomzn TOMPD-63SW is designed for minimal maintenance. However, regular checks can ensure optimal performance and safety:

  • Czyszczenie: Periodically clean the device's exterior with a dry, soft cloth. Do not use abrasive cleaners or solvents.
  • Kontrola połączenia: Annually, or as needed, verify that all wiring connections are secure and free from corrosion. Ensure power is disconnected before performing this check.
  • Aktualizacje oprogramowania układowego: Check the mobile application periodically for any available firmware updates for the device. Updates can improve performance and add new features.

9. Rozwiązywanie Problemów

If you encounter issues with your TOMPD-63SW, refer to the following common problems and solutions:

  • Urządzenie nie włącza się:
    • Sprawdź główne źródło zasilania i wyłącznik obwodu.
    • Verify all wiring connections (L-IN, N-IN) are correct and secure.
  • Brak połączenia Wi-Fi:
    • Ensure your Wi-Fi network is 2.4GHz (5GHz networks are typically not supported by these devices).
    • Check the Wi-Fi signal strength at the device's location.
    • Uruchom ponownie router Wi-Fi.
    • Attempt to re-pair the device with the mobile application (refer to app instructions for pairing mode).
  • Częste wyłączanie się urządzenia:
    • Check the load connected to the device; it might be drawing excessive current or experiencing a fault.
    • Review nadmierna objętośćtage, pod objętościątage, and leakage current protection settings in the mobile application. They might be set too sensitively.
    • Inspect the electrical system for actual faults (e.g., ground fault, short circuit).
  • Niedokładne odczyty:
    • Ensure wiring connections are correct and tight.
    • Compare readings with a calibrated multimeter if possible.

If the problem persists, contact customer support or a qualified electrician.

10. Gwarancja i wsparcie

Gwarancja: Please refer to your purchase documentation, retailer, or the manufacturer's official website for detailed warranty information regarding the Tomzn TOMPD-63SW device.

Wsparcie techniczne: For technical assistance, troubleshooting beyond this manual, or inquiries about your device, please contact your point of purchase or the official Tomzn customer support channels. Ensure you have your product model number (TOMPD-63SW) and purchase details ready when contacting support.

© 2023 TOMZN. All rights reserved.