DX-SMART LR02

DX-Smart LR02 LoRa Module User Manual

Model: LR02

Manufacturer: DX-SMART

1. Wprowadzenie

The DX-Smart LR02 is a low-power LoRa module designed for wireless data transmission. It integrates an ASR6601 RF chip and supports UART serial communication, enabling transparent data transfer between devices. This module operates within the 433~475MHz frequency range and is suitable for various Internet of Things (IoT) applications requiring long-range and low-power connectivity.

Główne cechy obejmują:

  • ASR6601 SOC Chip with 32-bit ARM STAR Core.
  • Maximum Frequency: 48MHz.
  • UART Serial Communication with configurable baud rates (1200 to 128000).
  • Extensive AT command set for module configuration.
  • Support for 410~493MHz frequency range, ensuring global compatibility.
  • High power PA with +22dBm output.
  • Maximum Receiver Sensitivity: -138dBm.
  • Supports sleep mode and wake-on-air mode.
  • Line-of-sight distance up to 5km in open areas.
  • Objętość operacyjnatage: 3.3V-5.5V (typical: 5V).
  • Module Size: 36(L)x16.5(W)x4(H)mm.
  • Certyfikaty CE, FCC, RoHS.

2. Konfiguracja i podłączenie sprzętu

This section details the physical connection of the LR02 module, including pinout and wiring diagrams. Ensure correct polarity when connecting the module to an adapter board or development environment.

2.1 Module Pinout

The LR02 module features a standard pinout for easy integration. Refer to the diagram below for pin identification and function.

LR02 Module Pinout and Wiring Diagram

Rysunek 2.1: LR02 Module Pinout and Example Wiring Diagram. The diagram illustrates the pin assignments for the LR02 module and a typical connection to an adapter plate, showing connections for M0, M1, PXD, TXD, RXD, AUX, VCC, and GND.

  • M0, M1: Reserved, customizable IO ports.
  • PXD: Not explicitly defined in the diagram, but typically related to data transmission.
  • TXD: UART Transmit Data.
  • RXD: UART Receive Data.
  • AUX: Auxiliary pin (refer to detailed documentation for specific functions).
  • VCC: Power Supply (3.3V-5.5V).
  • masa: Grunt.

2.2 Stan wskaźnika

The module includes an indicator light to show its operational status:

  • Status pracy: Red light blinking.
  • Hibernation mode: Light off when hibernating, red light flashing when waking up.

3. Operating Modes and AT Commands

The LR02 module supports various working modes and is configured using a comprehensive set of AT commands via its UART serial interface. This allows for flexible integration into different applications without requiring custom LoRa programming.

3.1 Obsługiwane tryby pracy

The module can operate in three primary data transmission modes:

LR02 Module Working Modes and AT Command Set

Rysunek 3.1: Illustration of LR02 Module Working Modes (Transparent, Fixed-Point, Broadcast) and a partial AT Command Set. The diagram visually explains how data is transmitted in each mode and lists common AT commands for configuration.

  1. Module and Module Transparent Transmission: Requires the same channel for both sender and receiver to transmit data.
  2. Module and Module Fixed-Point Transmission: Communicates with modules using specified addresses and channels. Data format is hexadecimal: receiving address + receiving channel + data.
  3. Modules and Module Broadcast Transmission: Communicates with designated channel modules. Data format is hexadecimal: receiver channel + data.

3.2 AT Command Set

AT commands are used to configure and query the module's parameters. A serial port testing software can be used for this purpose.

Serial Port Testing Software and AT Command Examples

Rysunek 3.2: Screenshot of a UART Assistant Tools software demonstrating serial port testing and a table of common AT commands. This image shows how to interact with the module using AT commands and a software interface.

Do popularnych poleceń AT należą:

  • W: Test command (responds with OK).
  • +++: Enter/exit AT command mode.
  • AT+BAUD: Set/query baud rate.
  • AT+MODE: Set/query operating mode.
  • AT+SLEEP: Set/query power consumption mode.
  • AT+CHANNEL: Set/query working channels.
  • AT+MAC: Set/query device address.
  • AT+POWE: Set/query transmit power.
  • AT+IQ: Setting the IQ signal flip-flop.

For a complete list and detailed usage of AT commands, please consult the product information packages and technical documentation provided by DX-SMART.

4. Konserwacja

The DX-Smart LR02 module is designed for robust operation. To ensure its longevity and reliable performance, consider the following general maintenance guidelines:

  • Warunki środowiskowe: Używaj modułu w określonym zakresie temperatur i wilgotności. Unikaj narażania na działanie ekstremalnych temperatur, wilgoci i środowiska korozyjnego.
  • Obsługa fizyczna: Handle the module with care to prevent physical damage to components or solder joints. Avoid excessive force when connecting or disconnecting antennas and cables.
  • Zasilanie: Ensure a stable and clean power supply within the specified voltage range (3.3V-5.5V). Unstable power can affect performance and module lifespan.
  • Czyszczenie: W razie potrzeby delikatnie wyczyść moduł miękką, suchą ściereczką. Unikaj stosowania płynów i silnych środków chemicznych.
  • Aktualizacje oprogramowania układowego: Okresowo sprawdzaj producenta webOdwiedź naszą stronę, aby sprawdzić dostępne aktualizacje oprogramowania sprzętowego, które mogą poprawić wydajność lub dodać nowe funkcje. Postępuj zgodnie z instrukcjami dotyczącymi procedur aktualizacji.

5. Rozwiązywanie Problemów

If you encounter issues with your DX-Smart LR02 module, consider the following troubleshooting steps:

  • No Power/Indicator Off:
    • Sprawdź wolumen zasilaniatage mieści się w zakresie 3.3V–5.5V.
    • Sprawdź wszystkie połączenia zasilania pod kątem prawidłowego styku i polaryzacji.
    • Ensure the module is not in hibernation mode (indicator light off).
  • Communication Failure (UART):
    • Confirm TXD and RXD lines are correctly connected (TX of one device to RX of the other).
    • Verify that the baud rate settings on both the module (via AT commands) and the host device match.
    • Sprawdź, czy połączenia nie są luźne lub czy przewody nie są uszkodzone.
    • Ensure the module is not in sleep mode, which would prevent communication.
  • Poor Wireless Range/Connectivity:
    • Ensure the antenna is securely connected and appropriate for the operating frequency.
    • Check for obstructions between modules (e.g., thick walls, metal objects).
    • Verify that both modules are configured to the same frequency and channel.
    • Confirm transmit power settings using AT commands.
  • Moduł nie odpowiada na polecenia AT:
    • Ensure you are sending the correct AT command prefix (e.g., '+++' to enter command mode).
    • Check serial port settings (baud rate, data bits, parity, stop bits).
    • Confirm the module is powered on and not in a deep sleep state.

If problems persist after following these steps, please refer to the technical support section for further assistance.

6. Specyfikacje

Detailed technical specifications for the DX-Smart LR02 LoRa Module:

LR02 Module Key Features and Dimensions

Rysunek 6.1: Visual representation of the LR02 module highlighting key features and physical dimensions (35.6mm length, 18mm width, 2.54mm pin pitch).

ParametrSzczegół
Model układu scalonegoASR6601
Interfejs komunikacyjnyPort szeregowy UART
Typ bezprzewodowyRadio Frequency (LoRa)
Pasmo częstotliwości433~475MHz (Supports 410~493MHz)
Moc transmisji+22dBm
Czułość odbiornika-138dBm
Odległość komunikacyjnaUp to 5km (line-of-sight in open areas)
Obsługa szybkości transmisji1200, 2400, 9600, 19200, 38400, 57600, 115200, 128000
Objętość operacyjnatage3.3V-5.5V (Typical: 5V)
Temperatura pracy-40°C do +85°C
Wymiary modułu (dł. x szer. x wys.)36mm x 16.5mm x 4mm
CertyfikatyCE, FCC, RoHS
Drone Measured Communication Distance of LR02 Module

Rysunek 6.2: Image illustrating a drone-measured communication distance test, showing the LR02 module achieving a visible range of up to 5km in an open environment. Note: Actual performance may vary based on environmental factors.

7. Informacje o gwarancji

Specific warranty terms for the DX-Smart LR02 LoRa Module are typically provided at the point of purchase or within the product packaging. For detailed warranty information, including coverage period and conditions, please refer to the documentation supplied by your seller or contact DX-SMART directly.

8. Wsparcie techniczne i zasoby

DX-SMART provides comprehensive technical support and resources to assist with the integration and operation of the LR02 module. These resources include:

  • Dokumentacja techniczna: Detailed datasheets, user guides, and application notes.
  • AT Command Sets: Full documentation of all available AT commands for advanced configuration.
  • Module Footprints and Reference Design Schematics: For hardware integration.
  • Development/Test Tools: Software and hardware tools to aid in development and testing.

For further assistance or to access these resources, please contact DX-SMART customer service. You can typically find contact information through the 'User Guide', 'Product Information', or 'Service Support' sections on the manufacturer's official weblub za pośrednictwem dostawcy produktu.

© 2024 DX-SMART. All rights reserved.

Niniejsza instrukcja może ulec zmianie bez powiadomienia.

Powiązane dokumenty - LR02

Przedview DX-Smart LR02 Lora Module Product Information and Tutorial
Find comprehensive product information and tutorial videos for the DX-Smart LR02 Lora Module, featuring ASR6601 RF chip, low power, and long-range capabilities.
Przedview DX-LR02-433T22D 串口应用指导
本指南详细介绍了深圳大夏龙雀科技有限公司(DX-SMART)推出的 DX-LR02-433T22D 低功耗 LoRa 模组的串口应用、配置方法及 AT 命令详解。该模组基于 ASR6601 芯片,适用于智能表计、智能物流、智慧城市等多种物联网应用场景。
Przedview DX-LR02 5KM Long Range LoRa Module User Guide
User guide for the DX-LR02, a 5KM long-range LoRa module with 22dbm transmission power, operating at 868/915MHz, featuring the ASR6601 chip and UART serial port with AT command support. This document provides essential information for using the module.
Przedview DX-LR02-900T22D Serial Port Application Guide - DX-SMART LoRa Module
Comprehensive guide to the DX-LR02-900T22D LoRa module from DX-SMART, covering serial port configuration, AT commands, transmission modes, and application examples for IoT development.
Przedview DX-LR02-900T22D LoRa Module Technical Manual
Technical manual for the DX-LR02-900T22D low-power LoRa module by Shenzhen DX-SMART Technology Co., Ltd., detailing its features, specifications, application interfaces, electrical characteristics, mechanical dimensions, and usage guidelines.
Przedview Moduł LoRa DX-LR01: Przewodnik po aplikacjach szeregowych i poleceniach AT
Kompleksowy przewodnik po module LoRa DX-LR01 o niskim poborze mocy firmy Shenzhen Daxia Longque Technology Co., Ltd., szczegółowo opisujący wykorzystanie portu szeregowego, polecenia AT, parametry RF i przykładowe zastosowania.ampścieżki do inteligentnej bezprzewodowej transmisji danych.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.