1. Wprowadzenie
The S+S Regeltechnik RCO2-AS NT is a maintenance-free CO2 meter designed to monitor ambient air quality. It features a traffic light LED indicator and an acoustic signal to provide clear and immediate feedback on CO2 levels. This device is suitable for use in classrooms, offices, meeting rooms, hotels, apartments, and retail spaces, enabling energy-efficient and demand-oriented ventilation. This manual provides essential information for the safe and effective operation of your CO2 meter.
2. Koniec produktuview
The RCO2-AS NT measures CO2 concentration in the range of 0 to 3000 ppm using a high-precision NDIR (Non-Dispersive Infrared) optical sensor. The device features an auto-calibration function, ensuring reliable measurements. Visual indication is provided by five colored LEDs, and an acoustic alarm can be activated or deactivated via a DIP switch.
- LED Traffic Light System: Green (good air quality), Yellow (ventilation recommended), Red (intensive ventilation required).
- Sygnał akustyczny: Sounds when warning levels are reached, can be disabled.
- Bezobsługowy: Designed for long-term, reliable operation without regular maintenance.
- Automatyczna kalibracja: Ensures accurate CO2 measurements over time.

3. Instrukcje bezpieczeństwa
- Read this manual completely before operating the device.
- Nie wystawiaj urządzenia na działanie ekstremalnych temperatur, wilgoci ani bezpośredniego światła słonecznego.
- Use only the provided power adapter or a compatible power source as specified.
- Nie próbuj samodzielnie otwierać ani naprawiać urządzenia. Wszelkie prace serwisowe zleć wykwalifikowanemu personelowi.
- Trzymaj urządzenie z dala od wody i innych płynów.
4. Konfiguracja
4.1 Umieszczenie
For optimal performance, place the RCO2-AS NT in a central location within the area to be monitored. Avoid placing it near windows, doors, or ventilation outlets where air currents might distort readings. A general recommendation is to use one sensor per 30 m² of floor area.
4.2 Połączenie zasilania
- Connect the plug-in power supply to the device's power input port.
- Podłącz zasilacz do standardowego gniazdka elektrycznego.
- Upon power-up, the device will initiate a self-test and warm-up phase, which may take a few minutes. During this time, the LEDs may cycle or remain off.
4.3 Wstępna kalibracja
The RCO2-AS NT features automatic calibration. For accurate initial readings, it is recommended to operate the device in a well-ventilated area with fresh air for at least 24 hours after the first power-up. This allows the auto-calibration function to establish a baseline for CO2 levels.
5. Instrukcja obsługi
5.1 Reading the LED Indicator
The device uses a traffic light system to indicate CO2 levels:
- Zielona dioda LED: Air quality is good. No ventilation is currently needed.
- Żółta dioda LED: Ventilation is recommended. Open windows or activate ventilation systems.
- Czerwona dioda LED: Intensive ventilation is necessary. High CO2 levels detected, requiring immediate air exchange.
5.2 Sygnał akustyczny
The RCO2-AS NT can emit an acoustic signal when CO2 levels reach the warning (Yellow) or critical (Red) thresholds. This signal serves as an additional alert for users.
5.3 Disabling the Acoustic Signal
The acoustic signal can be deactivated using an internal DIP switch. To access the DIP switch:
- Ostrożnie otwórz urządzenie casinG. (Note: This should only be done by qualified personnel or with extreme care to avoid damaging internal components.)
- Locate the DIP switch labeled 'ON' or '1' on the circuit board.
- Toggle the switch to the 'OFF' position to disable the acoustic signal.
- Zamknij urządzenie casing bezpiecznie.

6. Konserwacja
The RCO2-AS NT is designed to be maintenance-free. However, to ensure continued accuracy and longevity:
- Czyszczenie: Delikatnie przetrzyj zewnętrzną część urządzenia miękką, suchą ściereczką. Nie używaj środków czyszczących o właściwościach ściernych ani rozpuszczalników.
- Przepływ powietrza: Ensure that the ventilation openings on the device are not obstructed.
- Automatyczna kalibracja: For the auto-calibration feature to function optimally, ensure the device is exposed to fresh air periodically (e.g., during regular room ventilation).
7. Rozwiązywanie Problemów
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Żadna dioda LED się nie świeci | Brak zasilania lub wadliwe połączenie. | Check power adapter and wall outlet. Ensure the power cable is securely connected. |
| Odczyty wydają się niedokładne | Device not properly calibrated or placed in an area with poor airflow. | Ensure the device has been exposed to fresh air for auto-calibration. Relocate the device to a more central position away from direct drafts or stagnatańskie powietrze. |
| Acoustic alarm does not sound | Acoustic signal is deactivated via DIP switch. | Refer to Section 5.3 to check and activate the acoustic signal if desired. |
| Acoustic alarm sounds constantly | Consistently high CO2 levels or faulty sensor. | Ensure adequate ventilation in the room. If the problem persists after ventilation, contact support. |
8. Specyfikacje
- Producent: S+S Technika regulacyjna
- Numer modelu: RCO2-AS NT
- Zakres pomiaru CO2: 0 - 3000 ppm
- Typ czujnika: NDIR (Non-Dispersive Infrared) optical sensor
- Źródło zasilania: Electrical cable (plug-in power supply included)
- Wymiary (dł. x szer. x wys.): 2.72 x 8.5 x 8.5 cm (ok. 1.07 x 3.35 x 3.35 cala)
- Waga: 225 grama (ok. 0.5 funta)
- Kolor: Biały
- Alarm: Acoustic signal (deactivatable)
- Zawartość zestawu: CO2 meter, plug-in power supply

9. Gwarancja i wsparcie
For information regarding warranty, technical support, or spare parts, please contact S+S Regeltechnik directly or refer to their official website. Please have your model number (RCO2-AS NT) and purchase details available when contacting support.