1. Wprowadzenie
The Pedrollo TOP 2 submersible pump is designed for pumping clear water without abrasive particles. This 0.5 HP, 115 Volt pump is engineered for ease of use and reliable operation, featuring total motor cooling and a double mechanical seal on the shaft for enhanced safety and durability.
It is particularly suitable for emergency draining of small flooded areas such as basements, garages, and fountains, as well as for emptying containers or water tanks, and draining water from dishwashers and washing machines.
2. Informacje dotyczące bezpieczeństwa
Always prioritize safety when operating electrical equipment, especially with water. Read and understand all instructions before installation and use.
- Podłączenie elektryczne: Ensure the power supply matches the pump's specifications (115 Volts). Connect the pump to a properly grounded outlet with a residual current device (RCD) for protection against electric shock.
- Jakość wody: This pump is designed for clear water. Do not use it for pumping flammable liquids, corrosive chemicals, or water containing large abrasive particles.
- Ograniczenia temperatur: The maximum liquid temperature for continuous operation is +40 °C. For intermittent use, the pump can handle temperatures up to +40 °C for a maximum period of 3 minutes.
- Obsługiwanie: Always use the integrated handle for lifting and lowering the pump. Never pull the pump by its power cable or discharge hose.
- Dzieci i zwierzęta: Trzymaj dzieci i zwierzęta domowe z dala od pompy i obszaru jej działania.
- Konserwacja: Przed przystąpieniem do czynności konserwacyjnych lub czyszczenia należy odłączyć pompę od zasilania.
3. Konfiguracja i instalacja
Prawidłowa instalacja ma kluczowe znaczenie dla wydajności i trwałości pompy.
3.1 Rozpakowanie i kontrola
Carefully remove the pump from its packaging. Inspect the pump for any signs of damage during transit. Ensure all components, including the 5-meter power cable and integrated float switch, are present.

Pedrollo TOP 2 Submersible Pump packaging and unit.
3.2 Connecting the Discharge Hose
Attach a suitable discharge hose to the pump's outlet. Ensure the connection is secure to prevent leaks during operation. The pump is designed to accommodate standard hose sizes.
3.3 Pozycjonowanie pompy
Place the pump on a stable, flat surface in the area to be drained. Ensure the pump is fully submerged in the water before starting. The maximum immersion depth for the TOP 2 model is 3 meters.

Pedrollo TOP 2 Submersible Pump showing the integrated handle and float switch.
3.4 Regulacja wyłącznika pływakowego
The pump features an integrated float switch for automatic start and stop. The float switch activates the pump when the water level rises and deactivates it when the water level drops to a certain point. Ensure the float switch can move freely without obstruction to function correctly.
4. Działanie
Once installed, operating the Pedrollo TOP 2 pump is straightforward.
4.1 Uruchomienie pompy
After ensuring the pump is correctly positioned and submerged, plug the power cable into a suitable electrical outlet. The integrated float switch will automatically start the pump when the water level reaches the activation point.
4.2 Praca automatyczna
The float switch will automatically turn the pump on and off based on the water level. This feature is ideal for continuous monitoring and draining of fluctuating water levels. The pump will continue to operate until the water level drops to the minimum emptying level of 14 mm from the bottom.
4.3 Zatrzymywanie pompy
To manually stop the pump, simply unplug it from the power outlet. The pump will also stop automatically once the water level falls below the float switch's deactivation point.
5. Konserwacja
Regularna konserwacja zapewnia optymalną wydajność i wydłuża żywotność pompy.
- Czyszczenie: Periodically clean the pump's exterior to remove any debris or sediment. Ensure the intake area is clear of obstructions.
- Kontrola wyłącznika pływakowego: Regularly check that the float switch moves freely and is not obstructed by debris.
- Kontrola wirnika: If the pump's performance decreases, inspect the impeller for blockages. The pump can handle solid particles up to Ø 10 mm. Larger particles may cause damage or blockages.
- Składowanie: If storing the pump for an extended period, especially in freezing conditions, ensure it is completely drained of water to prevent damage. Store in a dry, protected area.
6. Rozwiązywanie Problemów
This section addresses common issues you might encounter with your Pedrollo TOP 2 pump.
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Pompa nie uruchamia się | Brak zasilania Float switch not activated Przeciążenie silnika | Sprawdź połączenie zasilania i wyłącznik obwodu Ensure water level is high enough to activate float Pozostawić silnik do ostygnięcia; sprawdzić, czy nie ma przeszkód |
| Niski przepływ wody lub jego brak | Wąż wylotowy zagięty lub zablokowany Pump intake blocked Impeller damaged or clogged | Sprawdź i wyczyść wąż Clean pump intake screen Disconnect power and inspect/clean impeller |
| Pompa pracuje w sposób ciągły | Float switch stuck in 'on' position Ciągły dopływ wody | Sprawdź, czy wyłącznik pływakowy nie jest zablokowany Verify the source of water inflow |
If problems persist after attempting these solutions, contact qualified service personnel.
7. Specyfikacje
Technical details for the Pedrollo TOP 2 Submersible Pump.

Z bliska view of the Pedrollo TOP 2 Submersible Pump, highlighting the technical label.
- Model: GÓRA 2
- Moc: 0.5 KM
- Tomtage: 115 wolty
- Maksymalna głębokość zanurzenia: 3 metrów
- Maksymalna temperatura cieczy: +40 °C (for max 3 minutes)
- Sphere Passage (Max Particle Size): Ø10 mm
- Maximum Emptying Level: 14 mm from the bottom
- Tworzywo: Lane żelazo
- Źródło zasilania: Electric cable (5m length supplied)
- Zawartość zestawu: Integrated float for automatic start/stop
- Wymiary (opakowanie): Wymiary 31.6 x 20.9 x 19.5 cm
- Waga (opakowanie): 5.32 kilogramów
- Maksymalna wysokość podnoszenia: 3 metrów
8. Oficjalne filmy o produktach
No official product videos specifically for the Pedrollo TOP 2 submersible pump from a 'Seller' creator type were found in the provided data. The available video is for a different product (Truper submersible pump) and is therefore not included.
9. Gwarancja i wsparcie
For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact Pedrollo customer service directly. Keep your purchase receipt as proof of purchase.