Elitech Loget 260-TH

Instrukcja obsługi rejestratora danych temperatury i wilgotności w czasie rzeczywistym Elitech Loget 260-TH 4G

1. Wprowadzenie

This manual provides detailed instructions for the setup, operation, and maintenance of the Elitech Loget 260-TH 4G Real-time Temperature Humidity Data Logger. This device is designed for monitoring temperature, humidity, light, shock, and location in various cold chain applications, providing real-time data transmission via 4G network.

1.1. Zawartość opakowania

  • Elitech Loget 260-TH Data Logger (Reusable version)
  • Built-in 4G SIM Card
  • Instrukcja obsługi
  • Kabel USB typu C.

2. Koniec produktuview

The Loget 260-TH is a multi-sensor data logger equipped with a display and control buttons for easy interaction. It features internal sensors for temperature, humidity, light, and shock, along with LBS (Location-Based Service) for location tracking.

Elitech Loget 260-TH Data Logger with labeled parts

Figure 2.1: Elitech Loget 260-TH Data Logger with numbered components.

2.1. Identyfikacja komponentów

  1. Ekran wyświetlacza LCD: Shows current readings, status, and alerts.
  2. Kontrolka LED: Provides visual status updates (e.g., OK, Alarm).
  3. Activate/Airplane Mode Button: Used to activate the device or toggle airplane mode.
  4. Czujnik wewnętrzny: Measures ambient temperature and humidity.
  5. Back Hanging Hole: For mounting or securing the device.
  6. Przycisk Start/Stop: Initiates or terminates data logging.
  7. Numer seryjny: Unikalny identyfikator urządzenia.
  8. Czujnik światła: Detects ambient light levels.
  9. Data Transmission Indicator: Shows network activity and data upload status.

2.2. Główne cechy

  • Double Data Security: Features offline storage for up to 100,000 points to prevent data loss and supports shadow data recording for continuous monitoring even if logging is mistakenly stopped.
  • Multi-Source Sensing: Monitors internal temperature (-30~60℃), humidity (0~100%RH), light (0~52000Lux), shock (0g~16g), and location (LBS). Optional external sensors for pH value or CO2 are available separately.
  • Remote Monitoring via APP/Web: Real-time data is uploaded to the Elitech iCold Cloud platform via a built-in 4G SIM card. Upload intervals are configurable from 1 minute to 24 hours.
  • Kompleksowy system alarmowy: Cloud-based alarms can be received via Elitech iCold APP, SMS, Email, or the web platform. The device also provides local sound, screen, and indicator light alarms for offline events.
  • Auto Flight Mode & Electronic Fence: Complies with Do160 for aviation safety. Flight mode can be activated manually, scheduled, or automatically via an electronic fence (custom area activation).
  • iCold Platform: A cloud-based platform compatible with RCW series products for real-time monitoring, automatic alerts, online data analysis, and management. It complies with FDA CFR 21 Part 11 requirements and supports iOS and Android apps.

3. Konfiguracja

3.1. Ładowanie początkowe

Before first use, connect the Loget 260-TH to a power source using the provided USB Type-C cable and a standard USB charger (not included) to ensure the internal battery is fully charged. The battery indicator on the LCD will show charging status.

3.2. Device Activation and Platform Connection

  1. Włączanie: Press and hold the 'Start/Stop' button for a few seconds until the device powers on and the LCD screen illuminates.
  2. Połączenie internetowe: The built-in 4G SIM card will automatically attempt to connect to the network. The signal strength indicator on the LCD will show connection status.
  3. iCold Account Setup:
    • Download the Elitech iCold APP from your mobile app store or visit the Elitech iCold web platforma (http://new.i-elitech.com).
    • Zarejestruj nowe konto lub zaloguj się, jeśli już je posiadasz.
    • Add your Loget 260-TH device to your account using the serial number found on the device (refer to Figure 2.1, item 7).
  4. Konfiguracja: Once added, you can configure logging parameters such as upload interval, alarm thresholds, and sensor settings via the iCold platform.

4. Instrukcja obsługi

4.1. Starting and Stopping Logging

  • Rozpocznij rejestrowanie: Press and hold the 'Start/Stop' button until the logging indicator appears on the LCD. The device will begin recording data according to the configured settings.
  • Zatrzymaj rejestrowanie: Press and hold the 'Start/Stop' button again until the logging indicator disappears. Data logging will cease.

4.2. Tryb samolotowy

Airplane mode disables all wireless communication (4G) to comply with aviation regulations. Data logging continues internally.

Elitech Loget 260-TH Data Logger displaying Flight Mode feature

Figure 4.1: Loget 260-TH illustrating Flight Mode activation methods.

  • Aktywacja ręczna: Press the 'Activate/Airplane Mode' button (Figure 2.1, item 3) to toggle airplane mode on or off.
  • Scheduled Activation: Configure specific times for airplane mode activation via the iCold platform.
  • Electronic Fence Activation: Set up a custom geographical area in the iCold platform. The device will automatically enter airplane mode upon entering this area and exit upon leaving.

4.3. Data Access and Alarms

Elitech Loget 260-TH Data Logger next to a smartphone displaying the iCold app interface with data graphs

Figure 4.2: Loget 260-TH data displayed on the Elitech iCold mobile application.

  • Dane w czasie rzeczywistym: View live temperature, humidity, light, shock, and location data on the Elitech iCold APP or web platforma.
  • Dane historyczne: Access and analyze historical data, generate reports (PDF/CSV), and track routes through the iCold platform.
  • Powiadomienia alarmowe: Receive instant alerts via APP, SMS, or Email when configured parameters exceed set thresholds. The device also provides local visual and audible alarms.
Elitech Loget 260-TH Data Logger with a laptop showing PDF and CSV report export options from the iCold platform

Figure 4.3: Elitech iCold platform demonstrating PDF and CSV report export functionality.

5. Konserwacja

5.1. Pielęgnacja baterii

  • Recharge the device regularly, especially if it will be stored for an extended period.
  • Avoid exposing the device to extreme temperatures during charging or storage, as this can degrade battery life.

5.2. Czyszczenie

  • Przetrzyj urządzenie miękką, suchą ściereczką.
  • Nie należy używać środków czyszczących o właściwościach ściernych ani rozpuszczalników, ponieważ mogą one uszkodzićasing lub czujników.

5.3. Przechowywanie

  • Przechowuj urządzenie w chłodnym i suchym miejscu, z dala od bezpośredniego światła słonecznego.
  • Przed długotrwałym przechowywaniem należy upewnić się, że akumulator jest częściowo naładowany (około 50%).

6. Rozwiązywanie Problemów

6.1. Urządzenie się nie włącza

  • Ensure the device is fully charged. Connect it to a power source using the USB Type-C cable.
  • Verify that the 'Start/Stop' button is pressed and held for the required duration.

6.2. No 4G Network Connection

  • Check the signal strength indicator on the LCD. If weak, move to an area with better network coverage.
  • Ensure airplane mode is not active.
  • Contact Elitech support if the issue persists, as the built-in SIM card may require troubleshooting.

6.3. Data Not Uploading to iCold Platform

  • Confirm the device has a stable 4G connection.
  • Verify that the device is correctly added and configured in your iCold account.
  • Check the upload interval settings in the iCold platform.

6.4. Niedokładne odczyty

  • Ensure the sensors are not obstructed or exposed to direct heat/cold sources that do not reflect the ambient environment.
  • Allow the device to stabilize in a new environment for a few minutes before taking critical readings.

7. Specyfikacje

ParametrWartość
Numer modeluUS-LogEt260-TH-10PACK
Temperature Range (Internal)-30 ℃ do 60 ℃ (-22 ℉ do 140 ℉)
Humidity Range (Internal)Wilgotność względna od 0% do 100%
Zasięg czujnika światła0 do 52000 luksów
Shock Sensor Range0g do 16g
Śledzenie lokalizacjiLBS (usługa oparta na lokalizacji)
Pojemność przechowywania danych100,000 points (offline)
Łączność4G (Built-in SIM Card)
Interwał przesyłaniaConfigurable (1 minute to 24 hours)
Typ bateriiLitowo-jonowy (w zestawie)
InterfejsUSB typu C
ZgodnośćDo160 (Aviation Safety), FDA CFR 21 Part 11