This manual provides essential information for the safe and efficient operation, installation, and maintenance of your YORK Iceberg Split Inverter Air Conditioner. Please read it thoroughly before using the appliance and keep it for future reference.

YORK Iceberg Inverter Air Conditioner indoor unit in a living room

Image: YORK Iceberg Inverter Air Conditioner indoor unit installed in a living room setting.

Informacje dotyczące bezpieczeństwa

Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury. This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

  • Upewnij się, że zasilanie jest zgodne ze specyfikacją urządzenia.
  • Nie wkładaj palców ani żadnych przedmiotów do wlotu/wylotu powietrza.
  • Nie próbuj samodzielnie naprawiać urządzenia. Skontaktuj się z wykwalifikowanym personelem serwisowym.
  • Przechowuj pilota poza zasięgiem małych dzieci.
  • Zapewnij odpowiednie uziemienie, aby zapobiec porażeniu prądem.

Składniki produktu

Your YORK Iceberg Split Inverter Air Conditioner system includes the following main components:

  • Jednostka wewnętrzna
  • Jednostka zewnętrzna
  • Zdalne sterowanie
  • Filtry powietrza
  • Zestaw instalacyjny (rury, kable itp.)
YORK Iceberg Air Conditioner Outdoor Unit

Image: The outdoor unit of the YORK Iceberg Split Inverter Air Conditioner.

YORK Air Conditioner Remote Control

Image: The remote control for the YORK Iceberg Split Inverter Air Conditioner.

Organizować coś

Professional installation is recommended for split air conditioning systems. Ensure the following steps are completed by a qualified technician:

  1. Umiejscowienie jednostki wewnętrznej: Install the indoor unit on a wall, ensuring proper clearance from ceilings and adjacent walls for optimal airflow.
  2. Umiejscowienie jednostki zewnętrznej: Position the outdoor unit on a stable, level surface, away from direct sunlight and obstructions, allowing for adequate ventilation.
  3. Rurociągi czynnika chłodniczego: Connect the refrigerant lines between the indoor and outdoor units, ensuring no leaks. This unit uses R-32 refrigerant.
  4. Okablowanie elektryczne: Connect the power supply and communication cables according to the wiring diagram provided in the full installation manual. Ensure the unit is properly grounded.
  5. System drenażowy: Zainstaluj rurę spustową skroplin, aby zapewnić prawidłowe usuwanie wody z jednostki wewnętrznej.
  6. Początkowe uruchomienie: After installation, power on the unit and perform a test run to verify all functions are operating correctly.

Konfiguracja Wi-Fi

Your air conditioner features integrated Wi-Fi for remote control via a smartphone application. Follow these general steps to connect:

  1. Download the "MY YORK" application from your smartphone's app store.
  2. Zarejestruj konto i zaloguj się.
  3. Follow the in-app instructions to add your air conditioner. This typically involves putting the unit into pairing mode (refer to the remote control section for specific button combinations) and connecting to its temporary Wi-Fi network before linking it to your home Wi-Fi.
  4. Once connected, you can control the unit from anywhere using the app.
Man controlling YORK AC with smartphone via Wi-Fi

Image: A person using a smartphone to control the air conditioner, illustrating the Wi-Fi control feature.

Instrukcja obsługi

Operate your YORK air conditioner using the provided remote control or the MY YORK smartphone application.

Funkcje pilota zdalnego sterowania

Pilot zdalnego sterowania umożliwia dostosowanie różnych ustawień:

  • Włączanie/wyłączanie: Naciśnij MOC przycisk.
  • Wybór trybu: Użyj TRYB button to cycle through Cooling, Heating, Fan, and Dry modes.
  • Regulacja temperatury: Użyj TEMPERATURA + I TEMP. - przyciskami, aby ustawić żądaną temperaturę.
  • Prędkość wentylatora: Naciskać PRĘDKOŚĆ WIATRAKA to adjust the fan intensity (Auto, Low, Medium, High).
  • Funkcja huśtawki: Aktywuj HUŚTAWKA button for automatic vertical airflow direction. This model features 4-way airflow swing.
  • Tryb uśpienia: Naciskać SPAĆ for energy-efficient and quiet operation during sleep.
  • Regulator czasowy: Set the unit to turn on or off automatically using the REGULATOR CZASOWY pikolak.

Główne cechy

The YORK Iceberg Split Inverter Air Conditioner is equipped with several advanced features for enhanced comfort and efficiency:

Inverter Technology Icon

Technologia inwerterowa

Ensures high energy efficiency and reduced electricity consumption.

Even Air Distribution Icon

4-Way Airflow Swing

Distributes conditioned air evenly throughout the room for consistent comfort.

Quiet Operation Icon

Cicha praca

Designed to operate with minimal noise for a peaceful environment.

Ikona szybkiego chłodzenia

Szybkie chłodzenie

Achieves desired cooling temperatures rapidly.

Auto Restart Icon

Auto Restart

Automatyczne wznawianie pracy z poprzednimi ustawieniami po przerwie w dostawie prądu.

Golden Fins Icon

Golden Fins

Provides enhanced corrosion resistance for improved durability and lifespan.

Konserwacja

Regularna konserwacja zapewnia optymalną wydajność i wydłuża żywotność klimatyzatora. Zawsze odłączaj zasilanie przed przystąpieniem do jakichkolwiek czynności konserwacyjnych.

  • Czyszczenie filtra powietrza: Clean the air filters every two weeks or more frequently depending on usage. Remove filters, wash with mild detergent and water, rinse thoroughly, and dry completely before reinstalling. This model features a Nano Aqua filter.
  • Czyszczenie jednostki wewnętrznej: Wipe the indoor unit's surface with a soft, dry cloth. Do not use harsh chemicals or abrasive cleaners.
  • Czyszczenie jednostki zewnętrznej: Periodically clear any debris (leaves, dust) from around the outdoor unit to ensure proper airflow. Do not spray water directly onto electrical components.
  • Kontrola drenażu: Ensure the condensate drain pipe is clear and free of blockages.
  • Profesjonalny serwis: Zaplanuj coroczną konserwację przez specjalistę, aby sprawdzić poziom czynnika chłodniczego, połączenia elektryczne i ogólny stan systemu.

Rozwiązywanie problemów

Przed skontaktowaniem się z serwisem należy sprawdzić następujące typowe problemy:

ProblemMożliwa przyczynaRozwiązanie
Jednostka się nie włączaBrak zasilania, zadziałał wyłącznik automatyczny, baterie pilota są słabe.Sprawdź zasilanie, zresetuj wyłącznik, wymień baterie pilota.
Niewystarczające chłodzenie/ogrzewanieBrudne filtry powietrza, zablokowana jednostka zewnętrzna, wybrany zły tryb, zbyt wysokie/niskie ustawienie temperatury.Clean filters, clear outdoor unit, select correct mode, adjust temperature.
Niezwykły hałasLuźne części, obce przedmioty, nierówne urządzenie.Check for loose parts, remove obstructions, ensure unit is level. If noise persists, contact service.
Wyciek wody z jednostki wewnętrznejZablokowana rura spustowa, nieprawidłowa instalacja.Clear drain pipe. If issue persists, contact a professional for inspection.
Problemy z połączeniem Wi-FiRouter issues, incorrect Wi-Fi password, unit not in pairing mode.Restart router, re-enter password, re-attempt Wi-Fi setup process.

Specyfikacje

FunkcjaSzczegół
MarkaJORK
Nazwa modeluYORK Iceberg Split Inverter High Wall 18000 BTU
Numer modeluYHQE18XT2CHS-R4
Typ produktuKlimatyzator
Wydajność chłodzenia18,000 BTU
Moc grzewcza5.1 kW
Pojemność (tony)1.5 tona
Zalecana powierzchnia podłogi20 metrów kwadratowych
Typ instalacjiSystem dzielony
Typ falownikaInverter Present
Typ kompresoraPrzewijanie obrotowe
ChłodziwoR-32
Tomtage220 wolty
Źródło zasilaniaElektryczny przewodowy
Cechy specjalne4-way Airflow Swing
Typ filtraNano Aqua Filter
Metoda kontroliPilot zdalnego sterowania, kontrola aplikacji
EfektywnośćHigh Efficiency (BEE Star Rating: High Efficiency)
KolorBiały
Kraj produkcjiChiny
Waga przedmiotu62.5 kilograma
Wymiary opakowaniaWymiary 106 x 39 x 31 cm
Zawarte komponentyFilters, Remote Control
Saudi Energy Efficiency Label for YORK Air Conditioner

Image: Saudi Energy Efficiency Label for the YORK Iceberg Air Conditioner, showing high efficiency ratings. For more details, visit sls.gov.sa.

Informacje o gwarancji

Your YORK Iceberg Split Inverter Air Conditioner comes with the following warranty:

  • Gwarancja na sprężarkę: 7 lata
  • Gwarancja ogólna: 2 lata
  • Rodzaj gwarancji: Ograniczona gwarancja

Please retain your purchase receipt for warranty claims. The warranty covers manufacturing defects under normal use conditions. For detailed terms and conditions, refer to the warranty card included with your product or contact customer support.

Wsparcie

For technical assistance, service requests, or further inquiries, please contact YORK customer support. Refer to the contact information provided in your product packaging or visit the official YORK webwitryna dla Twojego regionu.

Producent: JORK

Webstrona: YORK Official Store on Amazon.sa

© 2024 YORK. Wszelkie prawa zastrzeżone. Niniejsza instrukcja ma charakter wyłącznie informacyjny.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.