1. Wprowadzenie
Niniejsza instrukcja zawiera szczegółowe instrukcje dotyczące instalacji, obsługi i konserwacji urządzenia. Ampinvt TG-6000W48V Hybrid Solar Inverter. This advanced unit integrates an inverter, AC battery charger, MPPT solar charge controller, and an AC auto-transfer switch into a single, efficient system. It is designed to provide reliable pure sine wave power for various applications, including residential, commercial, and mobile setups.

Rycina 1: Przód view z Ampinvt TG-6000W48V Hybrid Solar Inverter, showcasing jego wyświetlacza i elementów sterujących.
2. Główne cechy
- Zintegrowany system: Combines inverter, AC battery charger, MPPT solar charge controller, and AC auto-transfer switch.
- Wysoka wydajność: Transfer efficiency above 85%, with MPPT tracking efficiency up to 98%.
- Czysta fala sinusoidalna na wyjściu: Provides continuous, stable pure sine wave output, suitable for sensitive electronics.
- Split Phase Output: Available at 240Vac (HOT1+HOT2) and 120/240Vac output simultaneously.
- Regulowany prąd ładowania: Max charge current adjustable from 0-35A, allowing customization or disabling of charging.
- Robust MPPT Controller: 100A MPPT controller supports 48V lead-acid (Seal, AGM, Gel, Flooded) and lithium (LiFePO4, User Mode) batteries.
- Wysokie wejście fotowoltaiczne: Maximum PV Array Power of 5600W and MAX PV input voltage z 150V DC.
- Kompleksowa ochrona: Includes battery low/high voltage alarm, over temperature, overload, and short circuit protection.
- Built-in AVR Stabilizer: Isolates surge interference and ensures stable voltage.

Rysunek 2: Koniecview of the inverter's integrated features, including its 35A AC charger and 100A MPPT controller.
Figure 3: The inverter is compatible with a wide range of home and office appliances, providing 6000W continuous output.
Figure 4: The inverter supports various 48V battery chemistries, including SLD, FLD, GEL, AGM, and Lithium, with a user-configurable mode.
3. Instalacja i konfiguracja
3.1 Środki ostrożności
Before installation, ensure all power sources are disconnected. Always wear appropriate personal protective equipment. Consult a qualified electrician for wiring if you are unsure. Do not expose the inverter to water or excessive humidity.
3.2 Montaż
Mount the inverter in a well-ventilated area, away from direct sunlight, heat sources, and flammable materials. Ensure adequate clearance around the unit for proper airflow. The unit should be mounted vertically on a sturdy surface.
3.3 połączeń przewodów
Follow the connection diagram carefully. Ensure all connections are secure and properly insulated. Incorrect wiring can cause damage to the inverter or connected devices.
Figure 5: Comprehensive connection diagram illustrating how to integrate solar panels, utility grid, generator, battery, and various AC loads with the hybrid solar inverter.
- Wejście panelu słonecznego: Connect your solar array to the PV+ and PV- terminals. Ensure the maximum PV input voltage (150V DC) and power (5600W) are not exceeded.
- Podłączenie akumulatora: Connect the 48V battery bank to the battery terminals, observing correct polarity (positive to positive, negative to negative).
- Wejście AC: Connect the utility grid or generator AC power to the AC input terminals.
- Wyjście AC: Connect your AC loads (appliances, lights, etc.) to the AC output terminals. The inverter provides 120V/240V split phase output.
- Grunt: Aby zapobiec zagrożeniom elektrycznym, należy upewnić się, że falownik jest prawidłowo uziemiony.
4. Tryby pracy
Ten Ampinvt TG-6000W48V Hybrid Solar Inverter features five distinct working modes to optimize power management based on your specific needs:
- AC/Line Priority Mode: In this mode, the inverter prioritizes AC power from the utility grid or generator as the primary input. It provides AC output and automatically charges the connected battery bank. If AC power is unavailable, the inverter will seamlessly switch to battery power.
- Tryb priorytetu baterii: This mode prioritizes power supply from the battery bank. The inverter will draw power from the batteries until a low voltage protection threshold is reached. At this point, it will automatically transfer to market power (utility grid) supply. Once the battery is sufficiently recharged (e.g., by solar or AC charging), it will switch back to battery power.
- Tryb ekologiczny: Designed for energy saving, the inverter enters an automatic sleep state and stops output when the load is less than 10% of its capacity. When the load increases above 10%, the inverter automatically wakes up and resumes normal inversion.
- Generator Mode: This mode is specifically for use with unstable generator 240V power. The generator's AC output is connected to the inverter's AC input. The inverter's built-in AVR (Automatic Voltage Regulator) regulates the voltage and automatically matches the 60Hz municipal frequency, ensuring a stable output voltage within the normal operating range for your appliances.
- Tryb bezobsługowy: Gdy bateria jest naładowanatage drops to a low level, the inverter enters a standby (power-saving) state. It will remain in this state until the battery voltage recovers to a user-defined value (e.g., after solar charging). Once the voltage is restored, the inverter will automatically resume normal output, enabling fully automatic, unattended operation.
5. Konserwacja
Regularna konserwacja zapewnia długowieczność i optymalną wydajność falownika. Regularnie wykonuj następujące kontrole:
- Czystość: Keep the inverter and its ventilation openings clean and free from dust and debris. Use a dry cloth for cleaning.
- Znajomości: Periodically check all wiring connections for tightness and signs of corrosion. Loose connections can lead to overheating and poor performance.
- Stan baterii: Monitor your battery bank's health according to the battery manufacturer's guidelines. Ensure proper charging and discharge cycles.
- Środowisko: Upewnij się, że środowisko instalacji mieści się w określonym zakresie temperatury i wilgotności.
6. Rozwiązywanie Problemów
W tej sekcji znajdziesz rozwiązania typowych problemów, które możesz napotkać. W przypadku problemów, których tutaj nie wymieniono, skontaktuj się z obsługą klienta.
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Brak mocy wyjściowej | Niski poziom naładowania akumulatoratage, Overload, Input AC not present | Sprawdź pojemność akumulatoratage, Reduce load, Check AC input connection |
| Inverter alarm sounds | Overload, Over temperature, Battery fault | Reduce load, Ensure proper ventilation, Check battery connections/health |
| Bateria się nie ładuje | Charging current set to 0A, Solar panels not connected/producing, AC input fault | Adjust charging current setting, Check solar panel connections/output, Verify AC input |
| Wyświetlacz nie działa | No power to inverter, Display fault | Check battery and AC input connections, Contact support if power is present |
7. Specyfikacje
| Parametr | Wartość |
|---|---|
| Nazwa modelu | TG-6000W48V |
| Cotage | 6000 W (6 kW) |
| Źródło zasilania | Zasilany energią słoneczną i baterią |
| Wymiary produktu | 14.2 x 6.9 x 20 cala |
| Waga przedmiotu | 78.8 funta |
| Maksymalna moc układu fotowoltaicznego | 5600 W |
| Maks. Objętość wejścia PVtage | 150V prądu stałego |
| Pojemność bateriitage | 48 V prądu stałego |
| Objętość wejścia ACtage | 240 V AC |
| Objętość wyjścia ACtage | 120V/240VAC Split Phase |
| Kontroler ładowania MPPT | 100A |
| Ładowarka akumulatorów | Adjustable 0-35A |
| Efektywność transferu | Powyżej 85% |
| Producent | Top one power |
Figure 6: Physical dimensions of the inverter and a list of items included in the package.
8. Co znajduje się w pudełku
Po rozpakowaniu sprawdź, czy wszystkie przedmioty są obecne:
- 1 razy Ampinvt TG-6000W48V Hybrid Solar Inverter
- 1 x kabel do akumulatora
- 1 x Instrukcja obsługi (ten dokument)
9. Gwarancja i wsparcie
This product comes with a manufacturer's warranty. For specific warranty terms, duration, and claim procedures, please refer to the warranty card included with your product or contact the manufacturer directly. For technical support, troubleshooting assistance, or spare parts, please reach out to OAE customer service through their official channels.
Rysunek 7: Ampinvt Hybrid Solar Inverter is suitable for a wide range of practical applications, from residential homes to remote base stations.