WZRELB SPVC10K24V

WZRELB 10000W 24V Pure Sine Wave Split Phase Power Inverter

Model: SPVC10K24V User Manual

1. Wprowadzenie

This manual provides essential information for the safe and efficient operation of your WZRELB 10000W 24V Pure Sine Wave Split Phase Power Inverter. Please read this manual thoroughly before installation and use, and retain it for future reference.

2. Instrukcje bezpieczeństwa

  • Przeczytaj wszystkie instrukcje: Before operating the inverter, read all instructions and cautionary markings on the inverter, the batteries, and all appropriate sections of this manual.
  • Wykwalifikowany personel: Instalację i konserwację powinien wykonywać wyłącznie wykwalifikowany personel.
  • Wentylacja: Ensure adequate ventilation around the inverter. Do not install in a zero-clearance compartment.
  • Unikaj wilgoci: Do not expose the inverter to rain, snow, spray, or bilge water.
  • Proper Battery Connection: Connect the inverter to a 24V battery system only. Incorrect voltagMoże to uszkodzić falownik.
  • Grunt: Aby zapobiec porażeniu prądem elektrycznym, należy upewnić się, że falownik jest prawidłowo uziemiony.
  • Wyłącznik awaryjny: Dowiedz się, jak szybko odłączyć zasilanie w nagłych wypadkach.

3. Zawartość opakowania

Po otwarciu opakowania należy sprawdzić, czy wszystkie elementy są obecne i nieuszkodzone:

  • WZRELB 10000W 24V Pure Sine Wave Split Phase Power Inverter
  • DC Connection Cables (AWG5 cables, typically 2 black for negative, 2 red for positive)
  • Bezpieczniki
  • Instrukcja obsługi

Wideo: Rozpakowywanie i koniecview of the WZRELB Pure Sine Wave Inverter, showing included cables and manual. Note: Video title mentions 6000W, but content is relevant to general inverter features and setup.

4. Koniec produktuview

The WZRELB 10000W 24V Pure Sine Wave Split Phase Power Inverter converts 24V DC battery power to 120V/240V AC power. It features a high efficiency design, an LCD display for monitoring, and multiple protection functions.

4.1. Front Panel (AC Output)

Front panel of WZRELB 10000W inverter showing multiple AC outlets and hardwire terminals

Obraz: Front panel of the inverter with two 120V AC outlets and hardwire terminals for 120V and 240V output.

  • 120VAC Outlets: Two standard 120V AC outlets, each supporting up to 5000W.
  • 240VAC Hardwire Terminal (3-wire): For 240V AC output, up to 10KW max (L+N=240V).
  • Multi-mode Hardwire Terminal (4-wire): Supports L1+L2=240V, L1+N=120V, L2+N=120V, allowing simultaneous 120VAC and 240VAC output.
  • Przycisk zasilania: To turn the AC output on or off.
  • Ground Wire Connector: Do uziemienia bezpieczeństwa.

4.2. Rear Panel (DC Input)

Rear panel of WZRELB 10000W inverter showing DC input terminals and cooling fans

Obraz: Rear panel of the inverter, featuring positive and negative DC input terminals and cooling fans.

  • Zacisk dodatni (+): Czerwony zacisk do podłączenia dodatniego bieguna akumulatora.
  • Zacisk ujemny (-): Czarny zacisk do podłączenia ujemnego bieguna akumulatora.
  • Wentylatory chłodzące: Temperature-controlled fans for efficient heat dissipation.
  • Spark-Proof Nut: Designed to minimize sparks during connection.

4.3. Wyświetlacz LCD

LCD display of WZRELB 10000W inverter showing status, battery voltage, temperature, and output details

Obraz: LCD display showing various operational parameters of the inverter.

The LCD display provides real-time monitoring of the inverter's status:

  1. Inverter working status (Normal/Fault)
  2. Working temperature inside the inverter
  3. Pojemność bateriitagi pojemność
  4. AC1 120V voltagi i ampwymazać
  5. AC2 120V voltagi i ampwymazać
  6. Output of 240V and frequency (60Hz)

5. Instalacja

5.1. DC Battery Connection (24V System)

The inverter requires a 24V DC battery system. For a 24V system using two 12V batteries, connect them in series (positive of one battery to negative of the other). Ensure the battery bank is properly sized for your power needs.

Diagram showing DC connection steps for the inverter

Obraz: Step-by-step guide for connecting DC cables to the inverter, emphasizing spark-proof connection.

  1. Connect Negative Cable First: After connecting the black cable(s) to the battery's negative terminal, connect the other end of the black cable(s) to the inverter's negative terminal.
  2. Contact Spark-Proof Terminal: Briefly touch the spark-proof terminal with the positive cable for 3-5 seconds to discharge any residual capacitance.
  3. Podłącz przewód dodatni: Connect the red cable(s) to the battery's positive terminal, then connect the other end to the inverter's positive terminal.

Ważny: Use all provided cables. For 4 cables, use 2 black for negative and 2 red for positive. Ensure all connections are tight to maintain stable current flow.

5.2. AC Output Wiring

The inverter supports both 120V and 240V AC output. You can use the standard 120V outlets or the hardwire terminals for direct connection to your electrical panel.

Close-up of AC output terminals on the inverter

Obraz: Szczegółowy view of the AC output terminals, including L1, N, L2, and G (Ground) connections.

For hardwire connections:

  • L1 to Hot 1
  • L2 to Hot 2
  • N to Neutral
  • G do masy

The inverter can run 120V and 240V appliances simultaneously. Ensure the total amperage does not exceed 25A for the connection.

6. Działanie

Once the inverter is properly installed and connected to the battery bank, press the power switch on the front panel to turn it on. The LCD display will illuminate, showing the current operational status.

6.1 Podłączanie urządzeń

Plug your 120V AC appliances into the standard outlets or connect 120V/240V appliances to the hardwire terminals. Ensure the total wattage of connected appliances does not exceed the inverter's continuous power rating of 10000W.

Wideo: Demonstrates various applications of the inverter, powering appliances like electric stoves, baking pans, air fryers, and refrigerators. Note: Video title mentions 6000W, but content is relevant to general inverter applications.

The inverter is compatible with a wide range of appliances, including those for home, cabin, mobile business, RV, trailer, semi-truck, and boat use. It supports AGM, gel, flooded, lead-acid, and lithium-ion batteries.

7. Funkcje ochronne

The WZRELB inverter is equipped with multiple protection features to ensure safe and reliable operation:

  • Wentylator chłodzący sterowany temperaturą: Activates automatically to prevent overheating.
  • Niska objętośćtage Alarm/Wyłączenie: Chroni akumulatory przed nadmiernym rozładowaniem.
  • Wysoka głośnośćtage Alarm/Wyłączenie: Protects the inverter and connected devices from over-voltage.
  • Zabezpieczenie przed przeciążeniem: Shuts down if connected load exceeds capacity.
  • Zabezpieczenie przed zwarciem: Zapobiega uszkodzeniom spowodowanym zwarciem.
  • Ochrona przed przegrzaniem: Wyłącza się, jeśli temperatura wewnętrzna stanie się zbyt wysoka.
  • Internally Fused: Provides additional circuit protection.
  • Zabezpieczenie przed odwrotną polaryzacją akumulatora: Guards against incorrect battery connections.
WZRELB 10000W Split Phase Inverter with icons representing various protection features

Obraz: Nadview of the inverter highlighting its robust protection features.

8. Specyfikacje

FunkcjaSpecyfikacja
MarkaWZREŁB
Nazwa modeluSPVC10K24V
Cotage (ciągły)10000 watów
Moc wyjściowa szczytowa20000 watów
Wejście Voltage24 woltów prądu stałego
Objętość wyjściatage120 Volts AC, 240 Volts AC
Kształt fali wyjściowej elektrycznejCzysta fala sinusoidalna
EfektywnośćDo 91.6%
Typ wyświetlaczaLCD
Pozycja Wymiary (dł. x szer. x wys.)23" dł. x 12" szer. x 6.2" wys.
Waga przedmiotu37 funtów
KolorCzarny
Wbudowane mediaInverter, Cables, Fuse
Energy Specifications MetUL

9. Konserwacja

  • Regularne czyszczenie: Utrzymuj falownik w czystości, bez kurzu i zanieczyszczeń. Do czyszczenia używaj suchej ściereczki.
  • Sprawdź połączenia: Okresowo sprawdzaj wszystkie połączenia prądu stałego i przemiennego, aby mieć pewność, że są dobrze dokręcone i nie są skorodowane.
  • Wentylacja: Ensure cooling fans are not obstructed and operate freely.
  • Stan baterii: Monitor your battery bank's health and charge levels regularly to prolong their lifespan and ensure optimal inverter performance.

10. Rozwiązywanie Problemów

If you encounter issues with your inverter, refer to the LCD display for error codes or status messages. Common issues and basic troubleshooting steps include:

  • Brak mocy wyjściowej: Check battery connections, ensure the inverter is turned on, and verify battery voltage is within the operating range. Check for tripped circuit breakers or blown fuses.
  • Wyłączenie przeciążeniowe: Reduce the load connected to the inverter. Ensure the total wattage of appliances does not exceed the inverter's capacity.
  • Niska/wysoka objętośćtage Wyłączenie: Sprawdź pojemność akumulatoratage. If low, recharge batteries. If high, check charging system.
  • Wyłączenie z powodu nadmiernej temperatury: Ensure adequate ventilation around the inverter. Clear any obstructions from the cooling fans. Allow the inverter to cool down.
  • Zwarcie: Disconnect all loads and check for any short circuits in your wiring or appliances.

W przypadku powtarzających się problemów skontaktuj się z obsługą klienta.

11. Gwarancja

The WZRELB 10000W 24V Pure Sine Wave Split Phase Power Inverter comes with a 1-letnia gwarancja from the date of purchase. This warranty covers manufacturing defects and workmanship under normal use. It does not cover damage caused by misuse, improper installation, accidents, or unauthorized modifications.

Proszę zachować dowód zakupu na potrzeby roszczeń gwarancyjnych.

12. Obsługa klienta

For technical assistance, warranty claims, or any questions regarding your WZRELB inverter, please contact WZRELB customer support through the retailer where you purchased the product or visit the official WZRELB webwitryna do informacji kontaktowych.

© 2023 WZRELB. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.