Gavigain IO25B01

Gavigain Bistable Self-Locking Switch User Manual

Model: IO25B01

Wstęp

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Gavigain Bistable Self-Locking Switch (Model IO25B01). This mini 6-24V flip-flop latch relay module is designed for various applications requiring reliable bistable control, such as smart home systems, emergency lighting, and automotive electronics. Please read this manual thoroughly before using the product to ensure proper functionality and safety.

Informacje dotyczące bezpieczeństwa

Aby zapobiec obrażeniom ciała lub uszkodzeniu urządzenia, należy zawsze przestrzegać następujących środków ostrożności:

Produkt ponadview

The Gavigain Bistable Self-Locking Switch is a compact and reliable relay module designed for various control applications. It features a self-locking mechanism, allowing it to maintain its state (ON/OFF) after a momentary trigger pulse.

Główne cechy:

Identyfikacja komponentu:

Szczyt view of the Gavigain Bistable Self-Locking Switch module, showing the blue relay, screw terminals, and control circuitry.

Rysunek 1: Góra view of the Bistable Self-Locking Switch module.

The module consists of a compact circuit board with a blue relay, screw terminals for power and load connections, and a 3-pin header for trigger input. The relay is rated for 10A at 250VAC, 10A at 125VAC, 10A at 30VDC, and 10A at 28VDC.

Kątowy view of the Gavigain Bistable Self-Locking Switch module, showing the relay, screw terminals, and the 3-pin trigger header.

Rysunek 2: Kątowy view of the module, highlighting the trigger input pins.

The 3-pin header typically includes VCC (power input), GND (ground), and Trigger (signal input). The screw terminals are for connecting the load to be controlled by the relay.

Organizować coś

Follow these steps to set up your Bistable Self-Locking Switch module:

  1. Podłączenie zasilania: Connect your 6-24V DC power supply to the VCC and GND pins on the 3-pin header. Ensure correct polarity. The VCC pin is typically marked or is the leftmost pin when looking at the module with the relay on the left and the 3-pin header on the right.
  2. Załaduj połączenie: Connect the device or circuit you wish to control to the screw terminals. The relay has Normally Open (NO) and Normally Closed (NC) contacts, along with a Common (COM) terminal. Refer to the markings on the relay for specific connections. For most applications, you will connect your load between the COM and NO terminals if you want the load to turn ON when the relay is triggered.
  3. Połączenie wyzwalacza: Connect your trigger source (e.g., a momentary push button, MCU output) to the Trigger pin. The module is designed to respond to a low pulse trigger.
Diagram showing the IO25B01 6-24V trigger module with circuit background, illustrating potential connections.

Figure 3: Illustrative diagram of the module and its trigger mechanism.

Always double-check all connections before applying power to prevent damage to the module or connected devices.

Instrukcja obsługi

The Bistable Self-Locking Switch operates on a simple toggle principle:

  1. Stan początkowy: By default, when power is applied, the relay is in its released state (e.g., Normally Open contacts are open, Normally Closed contacts are closed).
  2. First Trigger: Apply a momentary low pulse to the Trigger pin. The relay will pull in (energize), changing its state. For example, if connected to NO, the load will turn ON. The relay will remain in this state even after the trigger pulse is removed.
  3. Second Trigger: Apply another momentary low pulse to the Trigger pin. The relay will release (de-energize), returning to its initial state. The load will turn OFF (if connected to NO).
  4. Subsequent Triggers: Each subsequent low pulse to the Trigger pin will toggle the relay's state between energized and de-energized.

This self-locking behavior makes it ideal for applications where a single button press needs to toggle a device's power state without continuous holding of the button.

Konserwacja

The Gavigain Bistable Self-Locking Switch module is designed for long-term, reliable operation with minimal maintenance. However, adhering to these guidelines can extend its lifespan:

Rozwiązywanie problemów

If you encounter issues with your Bistable Self-Locking Switch, refer to the following troubleshooting guide:

ProblemMożliwa przyczynaRozwiązanie
Relay does not energize/de-energize.
  • No power to module.
  • Incorrect power polarity.
  • Trigger signal not applied or incorrect.
  • Uszkodzony przekaźnik.
  • Check power supply connections (VCC, GND).
  • Verify VCC and GND are connected correctly.
  • Ensure a momentary low pulse is sent to the Trigger pin. Test trigger source.
  • If all else fails, the relay may be defective.
Load does not turn ON/OFF.
  • Incorrect load wiring.
  • Obciążenie jest wadliwe.
  • Relay contacts are damaged.
  • Verify load is connected to COM and NO/NC terminals correctly.
  • Przetestuj obciążenie niezależnie, aby upewnić się, że działa prawidłowo.
  • Check relay contacts for continuity when energized/de-energized.
Module gets excessively hot.
  • Overloaded relay contacts.
  • Nieprawidłowe wejście voltage.
  • Reduce load current to within specifications.
  • Sprawdź objętość wejściowątage is within 6-24V DC range.

Specyfikacje

ParametrWartość
ModelIO25B01
Objętość operacyjnatage6-24V DC
Relay Contact Rating (AC)10 A 250 V AC / 10 A 125 V AC
Relay Contact Rating (DC)10 A 30 V prądu stałego / 10 A 28 V prądu stałego
Tryb wyzwalaniaLow Pulse Trigger
Tryb działaniaBistable (Self-Locking)
WymiaryOkoło 1.85 x 0.63 x 0.71 cala (47 x 16 x 18 mm)
WagaOkoło 0.71 uncji (20 gramów)

Gwarancja i wsparcie

Gavigain products are manufactured with high-quality components and undergo rigorous testing to ensure reliability. For specific warranty information, please refer to the terms and conditions provided at the time of purchase or contact your retailer.