Thank you for choosing the Voktta Battery Capacity Voltage Meter. This device is designed to accurately monitor your battery's capacity, voltage, and temperature, providing essential data for various applications. It features a clear display, alarm functions, and broad compatibility with different battery types. Please read this manual thoroughly before installation and operation to ensure correct usage and optimal performance.

2. Funkcje produktu

  • Wielofunkcyjny wyświetlacz: Simultaneously shows battery capacity percentage, tomtage, and temperature (Celsius or Fahrenheit).
  • Zintegrowana ochrona: Equipped with a protective cover, dustproof and waterproof surface, and reverse input connection protection.
  • External Temperature Sensor & Buzzer: Includes an external temperature sensor for accurate readings and an internal buzzer for high/low voltage and over-temperature alarms.
  • Six Programmable Modes: Allows setting battery type, delay for ultra-low power mode, adjusting battery percentage limits, activating undervoltage alarm and threshold, activating temperature alarm, and voltage kalibracja.
  • Szeroka kompatybilność baterii: Compatible with 12V, 24V, 36V, 48V, 60V, 72V, 84V lead-acid batteries, lithium-ion batteries, polymer lithium-ion batteries, 3-15 series lithium-ion batteries, water batteries, and lithium iron phosphate batteries.
  • Szerokie zastosowanie: Suitable for use in jet skis, golf carts, RVs, lawnmowers, aquariums, DIY solar generators, and other systems requiring battery monitoring.

3. Zawartość opakowania

Proszę sprawdzić, czy w paczce znajdują się następujące elementy:

  • Voktta Battery Capacity Voltage Miernik
  • Connection Wires (Red for positive, Black for negative)
  • Zewnętrzny czujnik temperatury
  • Instrukcja obsługi (ten dokument)
Voktta Battery Capacity Voltage Meter with included wires and external temperature sensor
Image: The Voktta Battery Capacity Voltage Meter shown with its connection wires and external temperature sensor.

4. Informacje dotyczące bezpieczeństwa

  • Przed instalacją lub serwisowaniem urządzenia należy zawsze odłączyć je od zasilania.
  • Ensure correct polarity when connecting the wires (Red to positive, Black to negative) to prevent damage to the meter and battery.
  • Nie przekraczać określonej objętości roboczejtagZakres (10-100V).
  • Keep the device away from extreme temperatures, moisture, and corrosive environments.
  • Nie próbuj demontować ani modyfikować urządzenia. Wszelkie prace serwisowe zlecaj wykwalifikowanemu personelowi.

5. Koniec produktuview

The Voktta Battery Capacity Voltage Meter features a compact design with a clear LCD display and a single control button. The external temperature sensor provides accurate ambient or battery temperature readings.

Dimensions of the Voktta Battery Capacity Voltage Miernik
Obraz: Przód view of the meter displaying battery capacity, voltage, and temperature, with dimensions indicated.
Close-up of the Voktta Battery Capacity Voltage Meter showing external temperature sensor, internal buzzer, and display parameters
Obraz: Szczegółowy view highlighting the external temperature sensor, the internal buzzer location, and the three parameters displayed on the screen.

6. Instalacja i okablowanie

Aby przeprowadzić prawidłową instalację, wykonaj następujące czynności:

  1. Montowanie: Choose a suitable location for the meter, ensuring it is protected from direct impact and excessive vibration. The meter is designed for panel mounting.
  2. Podłączenie zasilania: Connect the red wire to the positive (+) terminal of your battery system and the black wire to the negative (-) terminal. Ensure a secure connection. The meter supports a wide voltagZakres wejściowy 10-100V.
  3. Podłączenie czujnika temperatury: Plug the external temperature sensor into its designated port on the back of the meter. Position the sensor to measure the desired temperature (e.g., near the battery for battery temperature, or in the environment for ambient temperature).
Z powrotem view of the Voktta Battery Capacity Voltage Meter showing wiring connections
Image: The rear of the meter, illustrating the connection points for the power wires and the external temperature sensor.

7. Konfiguracja początkowa

After connecting the meter, you may need to configure it for your specific battery type and preferences.

7.1 Włączanie/wyłączanie zasilania

Press the power button (usually located on the front panel) to turn the device on or off.

Close-up of the power button on the Voktta Battery Capacity Voltage Miernik
Obraz: Zbliżenie view of the power button, used for turning the device on and off.

7.2 Ustawianie typu baterii

The meter supports various battery types. Refer to the detailed programming instructions (often accessed by holding the power button or a dedicated 'SET' button) to select the correct battery chemistry and voltage configuration (e.g., 3S Lithium, 12V Lead-Acid).

Icons representing various battery types compatible with the Voktta Battery Capacity Voltage Miernik
Image: Visual representation of different battery types (e.g., lead-acid, lithium-ion) that are compatible with the meter.

8. Instrukcja obsługi

Once powered on and configured, the meter will display real-time battery information.

8.1 Tryby wyświetlania

The display typically shows battery capacity percentage, aktualna objętośćtage, and temperature. Some models allow switching between Celsius and Fahrenheit for temperature display.

Voktta Battery Capacity Voltage Meter showing temperature in Celsius and Fahrenheit
Image: The meter display illustrating the ability to switch between Celsius and Fahrenheit temperature units.

8.2 funkcji alarmu

The internal buzzer will activate if the battery voltage falls below the set low voltage threshold, exceeds the high voltage threshold, or if the temperature goes beyond the set limits. This provides an audible warning for critical conditions.

9. Zaawansowana konfiguracja

The meter offers several programmable modes for fine-tuning its operation. Access these modes by following the specific button press sequences outlined in the full product documentation (if provided separately) or by holding the main button for an extended period.

  • Ustawienie typu baterii: Configure the meter for your specific battery chemistry and cell count (e.g., LiFePO4, Li-ion, Lead-Acid, 3S, 4S, etc.).
  • Ultra-Low Power Mode Delay: Set a delay (10s, 20s, 30s, 60s, 120s adjustable) before the meter enters a low power consumption state to conserve energy.
  • Procent bateriitage Limity: Adjust the upper and lower voltage thresholds that correspond to 100% and 0% battery capacity for accurate percentage wyświetlacz.
  • Objętość poniżejtagAlarm: Activate and set the specific voltage threshold (e.g., 10.5V to 60.0V) at which the low voltage alarm will trigger.
  • Alarm nadmiernej temperatury: Activate and set the temperature threshold (e.g., 0°C to 79°C or 0°F to 179°F) at which the over-temperature alarm will trigger.
  • Tomtage Kalibracja: Wykonaj objtage calibration to ensure the most accurate readings.

10. Specyfikacje

ParametrWartość
MarkaWokta
Numer modeluB0BHSSKRVP
Objętość operacyjnatage10-100 V
Prąd roboczy8-10mA
Pobór mocy (tryb uśpienia)15-20uA
Tomtage Dokładność±0.1% ~ ±0.5%
Dokładność temperatury±0.5℃ ~ ±1℃ (built-in standard, external 30cm probe)
Zakres temperatur-19 ~ 80 ℃ / 0 ~ 179 ℉
Over-temperature Alarm Setting0 ~ 79 ℃ / 0 ~ 179 ℉
Niska objętośćtage Ustawienia alarmu10.5~60.0 V
Głośność brzęczyka60~80dB
Temperatura pracy-10~65℃
KolorCzarny
ZgodnośćCE, IP67, RoHS
Typ pomiaruWoltomierz

11. Rozwiązywanie Problemów

If you encounter issues with your Voktta Battery Capacity Voltage Meter, refer to the following common problems and solutions:

  • Brak wyświetlacza:
    • Check power connections: Ensure red wire is connected to positive and black to negative, and connections are secure.
    • Sprawdź pojemność bateriitage: Sprawdź pojemność bateriitage mieści się w zakresie roboczym 10–100 V.
  • Niedokładne odczyty:
    • Tomtage/Pojemność: Ensure the correct battery type and voltage configuration are set in the meter's settings. Perform voltage calibration if available.
    • Temperatura: Check if the external temperature sensor is properly connected and positioned.
  • Alarm ciągle się włącza:
    • Review alarm thresholds: Adjust the low voltage, duża objętośćtage, or over-temperature alarm settings to appropriate levels for your battery and application.
    • Check battery health: A constantly triggering low voltage alarm might indicate a failing battery.
  • Przyciski nie reagują:
    • Power cycle the device: Turn the meter off and then on again.
    • Upewnij się, że żadne zanieczyszczenia nie blokują przycisków.

12. Konserwacja

To ensure the longevity and accurate operation of your Voktta Battery Capacity Voltage Meter, follow these maintenance guidelines:

  • Czyszczenie: Do czyszczenia wyświetlacza i obudowy należy używać miękkiej, suchej ściereczki. Nie należy używać środków czyszczących o właściwościach ściernych ani rozpuszczalników.
  • Znajomości: Okresowo sprawdzaj wszystkie połączenia przewodów, aby mieć pewność, że są solidne i nie są skorodowane.
  • Ochrona środowiska: While the device has some dust and water resistance (IP67), avoid prolonged exposure to harsh weather conditions or direct water immersion.
  • Składowanie: Jeśli urządzenie będzie przechowywane przez dłuższy czas, należy odłączyć je od źródła zasilania i przechowywać w chłodnym, suchym miejscu.

13. Wsparcie

For any questions, technical assistance, or if you encounter issues not covered in this manual, please contact Voktta customer support. We are committed to providing assistance to resolve any problems you may experience.

Informacje kontaktowe można zazwyczaj znaleźć na opakowaniu produktu lub u sprzedawcy detalicznego. webmiejsce, w którym zakupiono produkt.