AutoLine Pro SS+

AutoLine Pro EVAP High Volume Smoke Machine Leak Tester - Shop Series Plus User Manual

Model: SS+

Wstęp

This manual provides detailed instructions for the safe and effective operation and maintenance of your AutoLine Pro Shop Series Plus EVAP High Volume Smoke Machine Leak Tester. This device is designed for professional and DIY automotive leak detection, featuring a built-in air pump for convenience and a ceramic smoke coil for consistent performance. Please read this manual thoroughly before initial use.

Informacje dotyczące bezpieczeństwa

Always adhere to the following safety guidelines to prevent injury or damage to the equipment and vehicle:

  • Operate the smoke machine in a well-ventilated area.
  • Ensure the vehicle's engine is off and cool before performing any tests.
  • Connect the power cables correctly to a 12V car battery, observing polarity.
  • Use only OEM-approved smoke fluid. The included fluid is safe for all vehicle systems and sensors.
  • Avoid direct contact with the smoke. While the fluid is safe, prolonged exposure to smoke should be avoided.
  • The built-in air compressor is regulated at 1 PSI to protect vehicle systems from high-pressure damage. Do not attempt to bypass this regulation.
  • Keep the device away from open flames or ignition sources.
  • Store the smoke machine and fluid in a cool, dry place, out of reach of children.

Co jest zawarte

Your AutoLine Pro Shop Series Plus Smoke Machine package contains the following items:

  • Shop Series Plus Smoke Machine with Built-in Air Pump
  • OEM Approved Smoke Fluid (8 oz)
  • Universal Metal Smoke Nozzle
  • Smoke Hose (7 FT)
  • Power Cables (10 FT)
  • Hood Hook
  • 10 Amp ATC Power Fuse
  • Instrukcja obsługi (ten dokument)
Contents of the AutoLine Pro Shop Series Plus Smoke Machine kit, including the red smoke machine, smoke fluid bottle, power cables, smoke hose, and nozzle.

Image: All components included in the AutoLine Pro Shop Series Plus Smoke Machine kit.

Instrukcje konfiguracji

  1. Fill with Smoke Fluid:

    Unscrew the cap of the smoke machine and carefully pour the included OEM-approved smoke fluid into the reservoir. Do not overfill. Ensure the cap is securely tightened after filling.

    Image showing smoke fluid being poured into the AutoLine Pro smoke machine.

    Image: Step-by-step illustration of filling the smoke machine with fluid.

  2. Connect Power and Air:

    Podłącz czerwony clamp of the power cable to the positive (+) terminal of a 12V car battery and the black clamp to the negative (-) terminal. The built-in air motor will activate automatically upon power connection. Ensure the smoke hose is securely attached to the machine's output port and the universal smoke nozzle is attached to the other end of the hose.

    Image showing the AutoLine Pro smoke machine connected to a 12V car battery.

    Image: Connecting the power cables to a 12V car battery.

  3. Prepare for Test:

    Once powered, the machine will begin to heat the fluid and produce smoke. Allow a few moments for smoke generation to stabilize. The built-in air compressor will maintain a safe 1 PSI pressure.

Instrukcja obsługi

Follow these steps to perform a leak detection test:

  1. Identify Test Area:

    Determine the system you wish to test (e.g., EVAP, vacuum, intake, exhaust). Ensure the system is sealed as much as possible before introducing smoke.

    Diagram illustrating various automotive systems that can be tested for leaks, including intake, engine block, EVAP, and exhaust systems, across different vehicle types.

    Image: Diagram showing common automotive systems for smoke testing.

  2. Insert Smoke Nozzle:

    Insert the universal smoke nozzle into an appropriate access point of the system being tested. The tapered design fits into various hoses and lines. For EVAP systems, connect to a suitable vacuum line or EVAP service port.

    Image showing smoke being emitted from the universal smoke nozzle of the AutoLine Pro smoke machine.

    Image: Smoke being emitted from the nozzle, ready for leak detection.

  3. Sprawdź, czy nie ma wycieków:

    As smoke fills the system, visually inspect for any smoke escaping from cracks, loose connections, worn gaskets, or seals. The machine can produce smoke for up to 1.8 hours non-stop, allowing ample time for thorough inspection.

  4. Pełny test:

    Once the leak is identified or the test is complete, disconnect the power cables from the battery. Remove the smoke nozzle from the vehicle system.

Konserwacja

  • Uzupełnianie płynów:

    Regularly check the smoke fluid level. Refill with AutoLine Pro OEM-approved smoke fluid as needed. Using alternative fluids may affect performance or damage the unit.

    Bottle of AutoLine Pro smoke fluid, labeled OEM Approved.

    Image: AutoLine Pro OEM Approved Smoke Fluid.

  • Ceramic Smoke Coil:

    The unit is equipped with a durable ceramic smoke coil designed for long-lasting performance. If smoke production significantly decreases or stops, the coil may need inspection or replacement. Refer to the warranty section for details on replacement parts.

  • Czyszczenie:

    Wipe down the exterior of the machine with a clean, dry cloth after each use. Ensure no fluid spills remain on the unit.

  • Składowanie:

    Store the smoke machine in its original packaging or a protective case in a cool, dry environment when not in use.

Rozwiązywanie problemów

ProblemMożliwa przyczynaRozwiązanie
No smoke productionLow fluid level, power not connected, faulty ceramic coil, blown fuse.Check fluid level and refill. Ensure power cables are securely connected to a 12V battery. Inspect the 10 Amp ATC fuse and replace if blown. Contact customer support if the ceramic coil is suspected to be faulty.
Weak smoke outputLow fluid level, insufficient warm-up time, partially clogged nozzle.Ensure fluid is at an adequate level. Allow the machine sufficient time to heat up. Check the smoke nozzle for obstructions and clean if necessary.
Air pump not operatingPower not connected, internal motor issue.Verify power connection to the 12V battery. If power is connected and the motor does not run, contact customer support.
Smoke machine overheatingProlonged continuous use beyond recommended limits (though designed for 1.8 hours non-stop).Disconnect power and allow the unit to cool down. Ensure adequate ventilation during operation.

Specyfikacje

  • Marka: AutoLine Pro
  • Nazwa modelu: Shop Series Plus (SS+)
  • Źródło zasilania: 12V DC (via car battery)
  • Kompresor powietrza: Built-in, 1 PSI regulated
  • Tworzywo: Metal
  • Waga przedmiotu: 3.61 funta
  • Wymiary produktu: 5" gł. x 5" szer. x 8" wys.
  • Smoke Output Duration: Up to 1.8 hours non-stop
  • Kod UPC: 850032284288

Gwarancja i wsparcie

AutoLine Pro offers a Dożywotnia gwarancja covering all manufacturer and operational defects for your smoke machine. This includes replacement of the unit or parts, such as the ceramic smoke coil, free of charge. For warranty claims or technical assistance, please contact AutoLine Pro customer support.

Our dedicated customer support team is available 24/7 to assist you with any questions or issues you may encounter. Please visit the official AutoLine Pro website or refer to the contact information provided with your product for support details.

© 2025 AutoLine Pro. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.