1. Informacje dotyczące bezpieczeństwa
Please read all safety instructions carefully before installing or operating the Fresh-Aire UV APCO Compact In-Duct Air Purifier. Failure to follow these instructions may result in electric shock, fire, or other hazards.
- Zagrożenie promieniowaniem UV: This product uses UVC light. Direct exposure to UVC light can cause temporary or permanent eye and skin irritation. Always disconnect power before servicing.
- Zagrożenie elektryczne: Installation requires working with electrical wiring. Ensure power is disconnected at the circuit breaker before any installation or maintenance. It is recommended that installation be performed by a qualified HVAC technician.
- Umieszczanie produktu: Position the unit so the UV light does not shine directly on non-UV resistant materials such as filters, humidifiers, or flexible ductwork, as this may cause degradation.
- Wentylacja: Podczas pracy należy zapewnić odpowiednią wentylację.
2. Koniec produktuview
The Fresh-Aire UV APCO Compact In-Duct Air Purifier is designed to improve indoor air quality by combining UVC light and activated carbon filtration. This system targets odors, bacteria, mold, and volatile organic compounds (VOCs) within your HVAC system.
Główne cechy:
- Kompaktowa konstrukcja: Ideal for smaller HVAC ducts and systems from 1-5 tons, requiring only 10 inches of clearance within the duct for installation.
- Dual UVC Lamps: Includes two UVC lamps with a 2-year lifespan for effective germicidal action.
- Carbon Matrix Filter: Features four activated carbon PCO cells that attract and hold odors and microbes, which are then catalyzed by UVC light. These cells are self-cleaning.
- Zdalne zasilanie: Equipped with a 120-277VAC external tethered power supply.
- Praca ciągła: Designed for 24/7 operation to maintain consistent air purification.


3. Konfiguracja i instalacja
Installation of the Fresh-Aire UV APCO Compact In-Duct Air Purifier is designed to be straightforward, but due to electrical connections and duct modifications, professional installation by a qualified HVAC technician is recommended.
Lista kontrolna przed instalacją:
- Ensure the HVAC system is powered off at the circuit breaker.
- Verify sufficient clearance (minimum 10 inches) within the ductwork for the unit.
- Gather necessary tools: drill, hole saw (appropriate size for mounting plate), screwdriver, safety glasses, gloves.
Kroki instalacji:
- Wybierz miejsce instalacji: The unit should be installed within the air handler or ductwork. For optimal results, orient the unit so that air flows past the UV light first, before the carbon matrix. Avoid direct UV light exposure to non-UV resistant materials.
- Mark and Cut Duct Opening: Use the provided template to mark the precise location for the opening in the supply duct. Carefully cut the opening. The return duct can also be used, but the supply duct is generally preferred.
- Montaż urządzenia: Insert the supplied mounting plate into the cut opening. Secure it using screws for metal ducts or by bending the tabs for duct board types.
- Zainstaluj UV Lamps: Carefully insert the separately packaged UV lamps into the main unit. Connect the lamp plugs securely.
- Podłącz zasilanie: Connect the unit to the 120-277VAC external tethered power supply. Ensure all electrical connections are secure and comply with local electrical codes.
- Bezpieczna okładka: Fasten the cover over the main unit.
- Przywróć zasilanie: Once installation is complete and all connections are verified, restore power to the HVAC system at the circuit breaker.
- Sprawdź działanie: Sprawdź viewing hole on the unit to confirm the UV lamps are illuminated, indicating proper operation.


4. Instrukcja obsługi
The Fresh-Aire UV APCO Compact In-Duct Air Purifier is designed for continuous, 24/7 operation. Once properly installed and powered, the unit will automatically begin purifying the air circulating through your HVAC system.
- Continuous Purification: UVC lamps and carbon matrix cells work continuously to reduce airborne contaminants.
- Ozone Absorption: The titanium dioxide infused carbon cells surrounding the UV lamps are designed to absorb any ozone emitted by the UVC lamps, ensuring no ozone is released into your indoor environment.
- Potwierdzenie wizualne: Mały viewing port on the unit allows for visual confirmation that the UVC lamps are operational. A blue glow indicates the lamps są włączone.

5. Konserwacja
The Fresh-Aire UV APCO system is designed for minimal maintenance. The carbon matrix cells are self-cleaning, and the UVC lamps have an extended lifespan.
- UVC lamp Wymiana: The included dual UVC lamps are rated for a 2-year lifespan. It is recommended to replace the lamps every two years to ensure optimal germicidal effectiveness.
- Czyszczenie: Periodically inspect the unit for any dust or debris accumulation. If necessary, gently wipe the exterior of the unit with a dry cloth after disconnecting power. Do not use liquid cleaners directly on the lamps or internal components.
- Inspekcja profesjonalna: It is advisable to have your HVAC system, including the APCO unit, inspected by a qualified technician during routine HVAC maintenance.
6. Rozwiązywanie Problemów
If you experience issues with your Fresh-Aire UV APCO Compact In-Duct Air Purifier, refer to the following common troubleshooting steps:
- Unit Not Illuminating:
- Check if the HVAC system has power.
- Verify that the unit's power supply is securely connected.
- Upewnij się, że UVC lamps are properly seated and connected.
- Jeśli jaamps are older than 2 years, they may need replacement.
- Reduced Air Quality Improvement:
- Ensure the HVAC system's air filter is clean and replaced regularly.
- Confirm the UVC lamps are still operational (check viewing port).
- Verify proper airflow through the ductwork.
- Nietypowe dźwięki:
- Disconnect power and inspect the unit for any loose components or obstructions.
- If the noise persists, contact a qualified technician.
For issues not resolved by these steps, please contact customer support or a qualified HVAC professional.
7. Specyfikacje
| Specyfikacja | Szczegół |
|---|---|
| Numer modelu | TUV-APCO-RT-DT2 |
| Marka | Fresh-Aire UV |
| Wymiary produktu (Gł. x Szer. x Wys.) | 21.53" x 8.37" x 8.5" |
| Waga | 5.2 funtów |
| Cotage | 21 watów |
| Tomtage | 120-277 VAC |
| Lamp Typ | Dual UVC (2-year lifespan) |
| Typ filtra | Carbon Matrix Filter (PCO cells) |
| Wymagane zezwolenie | 10 inches within duct |
| Orzecznictwo | Certyfikat UL |
| Typ kontrolera | Zdalne sterowanie |
8. Informacje o gwarancji
Specific warranty details for the Fresh-Aire UV APCO Compact In-Duct Air Purifier are typically provided at the point of purchase or included with the product packaging. Please refer to your purchase documentation for the most accurate and up-to-date warranty terms and conditions.
Generally, UVC lamps are considered consumable items and may have a separate warranty period or expected lifespan (e.g., 2 years for the lamps included with this model).
9. Wsparcie
For technical assistance, replacement parts, or further inquiries regarding your Fresh-Aire UV APCO Compact In-Duct Air Purifier, please contact Fresh-Aire UV customer support through their official webwitrynę lub dane kontaktowe podane w dokumentacji produktu.
When contacting support, please have your product model number (TUV-APCO-RT-DT2) and date of purchase readily available.